DSG-01 Series Solenoid Operated Directional Valves
344
1/8 Solenoid Operated Directional Valves, DSG-01 Series
These are Solenoid Operated Directional Valves of high pressure, high
flow and low pressure drop, the features of which can be materialized
by employing a powerful wet type solenoid and the rational flow
channel design.
High Pressure & High Flow Rate
In comparison to our existing lines, both the pressure and flow of
these valves are much increased.
Max. Operating Pressure: approx. 10 % increased [31.535 MPa
(4570 5080 PSI)]
Max. T-Line Back Pressure: approx. 30 % increased [1621 MPa
(2320 3050 PSI)]
Max. Flow Rate: approx. 60 % increased [63100 L/min (16.64
26.42 U.S.GPM)]
Low Pressure Drop
The pressure drop of these valves is reduced by 10 % from 1.0 to 0.9
MPa (145 to 131 PSI), in comparison to our existing lines*; the valves
effectively reduce the energy consumption of the unit.
{* At Flow Rate: 60 L/min (15.9 U.S.GPM), Spool Type: 3C2 (PA)}
Compact & Small Mass
Despite of high pressure, high flow and low pressure drop, these valve
bodies are compact and lightweight with DC double solenoids; the
overall length and mass are reduced from 210 to 205 mm (8.26 to 8.07
inch) and from 2.2 to 1.85 kg (4.85 to 4.08 lbs), respectively.
Shockless type available
In addition to the standard valves for high pressure and high flow, a
shockless type capable of minimizing noise and vibration in piping
during spool changeover is also available.
Stable Operation
Due to the powerful magnetic and spring force of the solenoids, these
valves exhibit a high tolerance to contaminants and especially stable
operation.
IP65-equivalent high dust- and water-proof
These valves demonstrate excellent dust- and water-proof
characteristics, in compliance with I. E. C. Pub. 529. IP65 and JIS C
0920 IP65 (dust- and jet-proof type).
Usable in products of various standards
These standard valves are CE certified for installation in equipment overseas.
UL/CSA certified products are also available.
Specifications
1. For details of L-DSG-01, please contact us.
2. Maximum flow indicates a ceiling flow depends on the type of spool and operating condition, refer to the List of Spool Functions on pages 347
to 351 for details.
Terminal Box Type
Plug-in Connector Type
Max. Changeover
Frequency
Cycle/min {min
–1
}
Max. Operating
Pressure
MPa (PSI)
Max. T-Line
Back Pressure
MPa (PSI)
Mass
kg
(lbs.)
Valve Type
Model Numbers
Max. Flow
L/min
(U.S.GPM)
2
1
Standard Type
DSG-01-3C - -70/7090
DSG-01-2D2- -70/7090
DSG-01-2B - -70/7090
S-DSG-01-3C - -70/7090
S-DSG-01-2B2- -70/7090
L-DSG-01-3C - -70/7090
L-DSG-01-2D2- -70/7090
L-DSG-01-2N - -70/7090
L-DSG-01-2B - -70/7090
Shockless Type
Low Wattage(14W)
Type
100
(26.4)
63
(16.6)
40
(10.6)
35
(5080)
25
(3630)
16
(2320)
21
(3050)
1.85
(4.08)
1.85
(4.08)
1.4(3.09)
1.4(3.09)
1.4(3.09)
1.85(4.08)
21
(3050)
16
(2320)
300
R Type Sol. Only
120
300
R Type Sol. Only
120
120
345
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
Sub-plate
Piping
Size
Sub-plat e
Model Numbers
Thread
Size
Japanese Standard "JIS "
Sub-plat e
Model Numbers
Thread
Size
European Design Standard
Sub-plat e
Model Numbers
Thread
Size
N.American Design Standard
Approx.
Mass
kg (lbs.)
Rc 1/8DSGM-01-31 1/8 BSP. FDSGM-01-3180
1/8 NPT
0.8 (1.8 )
Rc 1/4
Rc 3/8
1/4 BSP. F
1/4 NPT
3/8 NPT
0.8 (1.8 )
0.8 (1.8 )
1/8
Mounting Bolt
Descriptions Soc. Hd. Cap Screw (4 pcs.) Tightening Torque
Japanese Standard "JIS"
European Design Standard
N. American Design Standard
M5
×
×
45 Lg.
No. 10-24 UNC 1-3/4 Lg.
5 - 7 Nm (43 - 60 in. 1bs.)
Applicable to working pressure more than
25 MPa (3630 PSI): 6 - 7 Nm (52 - 60 in. 1bs.)
1/4
3/8
DSGM-01-3190
DSGM-01X-31
DSGM-01Y-31
DSGM-01X-3180 DSGM-01X-3190
DSGM-01Y-3190
For socket head cap screws in the table below are included.
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
1.
2.
3.
1
2
Solenoid Ratings
Valve Type Electric source
Coil
Type
Frequency
(Hz)
Source Ratin g
Voltage (V)
Serviceable Range
Inrush (A)
Holding (A) Power (W)
Current & Power at Rated Voltage
100
100
110
120
200
200
220
240
12
24
48
100
200
50
60
50
60
50
60
50
60
50/60
A100
A120
A200
A240
D12
D24
D48
R100
R200
80 - 110
90 - 120
96 - 132
108 - 144
160 - 220
180 - 240
192 - 264
216 - 288
10.8 - 13.2
21.6 - 26.4
43.2 - 52.8
90 - 110
180 - 220
2.42
2.14
2.35
2.02
1.78
1.21
1.07
1.18
1.01
0.89
0.51
0.37
0.44
0.42
0.31
0.25
0.19
0.22
0.21
0.15
2.45
1.23
0.61
0.33
0.16
AC
DC (K Series )
AC
DC Rectified (R )
Standard
Type
Shockless
Type
29
29
AC solenoid is not available in shockless type.
R type models with built-in current rectifier is recommended for shockless operation with AC power.
Inrush current in the above table show rms values at maximum stroke.
There are more coil types other than the above. For details, please make inquiries.
The coil type numbers in the shaded column are handled as opotinal extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
SOL b
SOL b
Lock Nut
Push Button
Plug-in Connector
With Indicator Light
Options
Push Button with Lock Nut
Can be used for manual changeover of spool. The push button
can be locked in the pressed condition.
Plug-in Connector with Solenoid Indicator Light
These are the indicator light incorporated plug-in connector
type solenoids. Energisation or de-energisation of the solenoid
can be easily identified with the incorporated indicator light.
DSG-01 Series Solenoid Operated Directional Valves
346
Model Number Designation
2
1
1
F-
F:
S-
DS G -
01
-2 B
2 A -D24 -C
-N
-70 -L
Special
Seals
Shockless
Type
Series
Number
Valve
Size
Number
of Valve
Positions
Spool-
Spring
Arrangement
Spool
Type
Special Two
Position Valve
Omit if not
require
d
Coil
Type
Manual
Override
Electrical
Conduit
Connection
Design
Number
Design
Standard
Models with
Reverse Mtg. of
Solenoid
Omit if not
require
d
For Phosphate
Ester Type
Fluids
(Omit if not
required
None:
Standard
Type
DSG:
Solenoid
Operated
Directional
Valve
S:
Shockless
Type
3:
Three
Positions
2:
Two
Positions
2:
Two
Positions
3:
Three
Positions
C:
Spring
Centred
D:
No-Spring
Detented
B:
Spring
Offset
C:
Spring
Centred
B:
Spring
Offset
None:
Manual
Override
Pin
C :
Push
Button
and
Lock Nut
(Option)
None:
Terminal
Box Type
N:
Plug-in
Connector
Type
N1 :
Plug-in
Connector
Type
with
Indicator
Light
(Option)
None:
Japanese
Std. "JIS"
90:
N.American
Design Std.
None:
Japanese
Std. "JIS"
and
European
Design
Std.
90:
N. American
Design
Std.
01
L
AC:
A100
A120
A200
A240
DC:
D12
D24
D48
R:
(AC
DC)
R100
R200
L
A
B
3
40
9
11
2,
4,
10,
12
2
3
8
2
4
2
70
60,
DC:
D12
D24
D48
R:
DC)
R100
R200
2
(AC
In case of the special two position valve, please refer to page 352 for details.
N1 is not available for R type solenoids.
In the table above, the symbols or numbers highlighted with shade represent the optional
extras. The valves with model number having such optional extras are handles as options,
therefore, please confirm the time of delivery with us before ordering.
1.
2.
347
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
100
100 80
90 63
90
85
80
43 23
40 23
100
100
100
100
80
85
70
10
DSG 01 3C2
DSG
01 3C3
DSG
01 3C4
DSG
01 3C40
DSG
01 3C60
DSG
01 3C9
DSG
01 3C10
DSG
01 3C11
DSG
01 3C12
DSG
01 2D2
DSG
01 2B2
DSG
01 2B3
DSG
01 2B8
16 25 31. 5 35 10 16 25 31. 5 35 10 16 25 31. 5 35
100
100 80
90 63
90
85
80
43 23
40 23
100
100
100 70
100
100
100 70
80
85
70
100
100 80
90 63
90
90 26
85
80 30
42 23
38 23
100
100 63
80 20
100
100 63
80 20
80
85
70
100
100 77
90 63
90 22
43 14
80 40
63 15
42 23
36 23
100
100 33
70 20
100
100 33
70 20
80
85
70
100
100 77
90 63
35 18
30 11
80 22
25 10
42 23
35 23
100
100 27
40 19
100
100 27
40 19
80
85
70
100 43
57 38
70 46
45 30
100 38
50 31
85 40
70 26
54 32
48 30
20
100 50
100 37
23
100 50
100 37
45
20
50
26
100 41
53 31
70 46
45 30
76 28
38 20
85 35
50 24
54 32
47 30
15
100 37
55 25
20
100
37
55 25
45
16
50
17
80 21
29 17
70 46
45 30
67 15
20 10
85 24
32 16
52 32
47 30
10
100 20
29 14
13
100 20
29 14
45 21
36 18
16
50
13
60 17
19 10
70 46
45 30
57 10
16
7
60 16
22 13
52 32
47 30
10
78 16
20 11
10
78 16
20 11
45 16
28 13
15
50
11
38 15
13 9
70 46
45 30
35 7
12 5
55 12
18 10
52 32
47 30
8
62 13
15 10
5
62 13
15 10
38 13
22 12
13
50
10
100 43
57 38
70 46
45 30
100 38
50 31
85 40
70 26
54 32
48 30
20
100 50
100 37
100 65
70 50
100 50
100 37
50
85 63
85 30
80 70
70 48
80 50
35 20
100 41
53 31
70 46
45 30
76 28
38 20
85 35
50 24
54 32
47 30
15
100 37
55 25
85 52
57 40
100 37
55 25
50 45
50 45
80 50
60 33
80 70
70 48
70 40
23 15
80 21
29 17
70 46
45 30
67 15
20 10
85 24
32 16
52 32
47 30
10
100 20
29 14
72 45
50 25
100 20
29 14
50 42
50 42
63 40
50 28
80 70
70 48
60 20
15 8
60 17
19 10
70 46
45 30
57 10
16 7
60 16
22 13
52 32
47 30
10
78 16
20 11
65 34
43 19
78 16
20 11
45 40
45 40
44 32
40 28
80 70
70 48
45 10
10 5
38 15
13 9
70 46
45 30
35 7
12 5
55 12
18 10
52 32
47 30
8
62
13
15 10
60 27
35 18
62 13
15 10
45 40
45 40
44 32
40 28
80 70
70 48
30 10
7 5
a
b
PT
BA
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
b
AB
PT
b
AB
PT
b
AB
PT
P
A
T
B
P
A
T
B
P
A
T
B
Graphic
Symbols
Model
Numbers
Spool-Spring Arrangement
No. of Valve Positions
[Port "A" Blocked][Port "B" Blocked]
Max. Flow
Working Pressure MPa
Working Pressure MPa
Working Pressure MPa
L /min
Spring Centred
Three Positions
No-Spring
Detented
Spring Offset
Two Positions
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01- -A
T of the valves with a mark, please see page 351.
( Example )
The maximum flow rate is constant
regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
50 Hz, At minimum serviceable voltage
(80% of rated voltage)
50 Hz, At rated voltage
60 Hz, At rated voltage
60 Hz, At minimum serviceable voltage
(90% of rated voltage)
100
100 (43)
57 (38)
Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.
For the maximum flow rate in P
2.
DSG-01 Series Solenoid Operated Directional Valves
348
22
17
75
70
29
23
24
19
66
58
8
24
19
5
24
19
27
22
13
50
10
100
100
80
90
85
50
41
100
85
100
85
75
70
80
70
10
DSG 01 3C2
DSG
01 3C3
DSG
01 3C4
DSG
01 3C40
DSG
01 3C60
DSG
01 3C9
DSG
01 3C10
DSG
01 3C11
DSG
01 3C12
DSG
01 2D2
DSG
01 2B2
DSG
01 2B3
DSG
01 2B8
16 25 31. 5 35 10 16 25 31. 5 35 10 16 25 31. 5 35
100
55
78
70
100
62
85
65
66
58
20
100
74
23
100
74
45
20
50
26
28
23
78
70
38
30
30
25
66
58
10
36
28
13
36
28
40
30
16
50
13
25
19
78
70
31
25
26
21
66
58
10
28
20
10
28
20
30
25
15
50
11
100
55
78
70
100
62
85
65
66
58
20
100
74
100
85
100
74
50
46
32
75
65
53
35
100
100
80
90
85
50
41
100
85
100
85
75
70
80
70
100
100
80
90
42
65
45
50
41
100
85
35
100
85
35
75
70
80
70
100
100
80
50
26
40
30
50
41
100
80
23
100
80
23
75
70
80
70
100
100
80
38
20
33
26
50
41
100
40
20
100
40
20
75
70
80
70
45
35
78
70
58
48
52
36
66
58
15
56
43
20
56
43
45
16
50
17
45
35
78
70
58
48
52
36
66
58
15
56
43
60
46
56
43
50
45
31
23
75
65
35
30
28
23
78
70
38
30
30
25
66
58
10
36
28
40
32
36
28
50
42
24
19
75
65
23
17
25
19
78
70
31
25
26
21
66
58
10
28
20
36
28
28
20
45
40
22
18
75
65
19
13
22
17
75
70
29
23
24
19
66
58
8
24
19
32
24
24
19
45
40
22
18
75
65
17
12
P
A
T
B
P
A
T
B
P
A
T
B
a
b
PT
BA
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
b
AB
PT
b
AB
PT
b
AB
PT
[Port "A" Blocked][Port "B" Blocked]
Graphic
Symbols
Model
Numbers
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
Working Pressure MPa
Working Pressure MPa
Working Pressure MPa
L/mi
Spring Centred
Three Positions
No-Spring
Detented
Spring Offset
Two Positions
List of Standard Models and The Maximum Flow
Models with DC or R Type Solenoids: DSG-01- -D /R
T of the valves with a mark, please see page 351.
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
100
100
55
Notes: The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.1.
2.
The valve models with a mark are handled as
Options. If you choose suce valves, check the time
of delivery beforehand.
For the maximum flow rate in P
349
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
DSG 01 3C2
DSG
01 3C3
DSG
01 3C4
DSG
01 3C40
DSG
01 3C60
DSG
01 3C9
DSG
01 3C10
DSG
01 3C11
DSG
01 3C12
DSG
01 2D2
DSG
01 2B2
DSG
01 2B3
DSG
01 2B8
a
b
PT
BA
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
b
AB
PT
b
AB
PT
b
AB
PT
P
A
T
B
P
A
T
B
P
A
T
B
Graphic
Symbols
Model
Numbers
Spool-Spring Arrangement
No. of Valve Positions
[Port "A" Blocked][Port "B" Blocked]
Max. Flow
Working Pressure PSI
Working Pressure PSI
Working Pressure PSI
U.S.GPM
Spring Centred
Three Positions
No-Spring
Detented
Spring Offset
Two Positions
List of Standard Models and The Maximum Flow
Models with AC Solenoids: DSG-01- -A
1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080
26.4
26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0)
15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4)
26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4)
26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6)
26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4)
26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6)
26.4(17.2) 22.5(13.7) 19.0(13.7) 17.2(9.0) 15.9(7.1)
18.5(13.2) 15.1(10.6) 13.2(6.6) 11.4(5.0) 9.2(4.8)
26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4)
11.9(5.6) 11.9(4.2) 10.0(3.4)
9.5(4.8) 7.4(3.4) 5.8(3.2)
26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6)
26.4(13.2) 26.4(9.8) 26.4(5.3) 20.6(4.2) 16.4(3.4)
22.5(16.6) 21.1(13.2) 16.6(10.6) 11.6(8.5) 11.6(8.5)
22.5(7.9) 15.9(8.7) 13.2(7.4) 10.6(7.4) 10.6(7.4)
21.1(13.2) 18.5(10.6) 15.9(5.3) 11.9(2.6) 7.9(2.6)
9.2(5.3) 6.1(4.0) 4.0(2.1) 2.6(1.3) 1.9(1.3)
21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5) 21.1(18.5)
18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7) 18.5(12.7)
26.4(9.8) 14.5(6.6) 7.7(3.7) 5.3(2.9) 4.0(2.6)
13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)
13.2(11.9) 13.2(11.1) 11.9(10.6) 11.9(10.6)
26.4(10.0) 20.1(17.4) 17.7(4.0) 15.1(2.6) 9.2(1.8)
13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3)
22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2)
18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6)
14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4)
12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9)
22.5(10.6) 22.5(9.3) 22.5(6.3) 15.9(4.2) 14.5(3.2)
18.5(6.9) 13.2(6.3) 8.5(4.2) 5.8(3.4) 4.8(2.6)
14.2(8.4) 14.2(8.4) 13.7(8.4) 13.7(8.4) 13.7(8.4)
12.7(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9) 12.4(7.9)
26.4(10.0) 20.1(7.4) 17.7(4.0) 15.1(2.6) 9.2(1.8)
13.2(8.2) 10.0(5.3) 5.3(2.6) 4.2(1.9) 3.2(1.3)
26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1) 26.4(21.1)
23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6) 23.8(16.6)
11.4(6.1) 11.4(6.1) 11.1(6.1) 11.1(6.1) 11.1(6.1)
10.6(6.1) 10.6(6.1) 10.0(6.1) 9.5(6.1) 9.2(6.1)
23.8(6.9) 11.4(3.7) 7.9(2.9)
23.8(5.8) 9.2(4.8)
21.1(7.9) 16.6(4.0) 6.6(2.4)
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0)
26.4(16.6) 26.4(8.7) 26.4(7.1)
26.4(18.5) 21.1(5.3) 18.5(5.3) 10.6(5.0)
26.4(16.6) 26.4(8.7) 26.4(7.1)
21.1(10.6) 21.1(5.8)
18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2)
11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9)
15.1(10.0) 14.0(8.2) 7.7(4.5) 5.0(2.6) 3.4(2.4)
18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2) 18.5(12.2)
11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9) 11.9(7.9)
26.4(11.4) 26.4(10.8) 21.1(5.6) 15.9(4.5) 10.0(4.0)
26.4
23.8 23.8
22.5 22.5
22.5
21.1 21.1
23.8
26.4 26.4 26.4
26.4
26.4
26.4
26.4
26.4 26.4 26.4
21.1 21.1 21.1 21.1 21.1
22.5 22.5 22.5 22.5 22.5
18.5 18.5 18.5 18.5 18.5
13.2 13.2 13.2 13.2 13.2
5.3 4.2 4.2 4.0 3.4
6.9 4.5 3.4 2.9 2.6
11.9 11.9 13.2
26.4
26.4
26.4
26.4 26.4 26.4 26.4
5.3 4.0 2.6 2.6 2.1
6.1 5.3 3.4 2.6 1.3
5.3 4.0 2.6 2.6 2.1
T of the valves with a mark, please see page 351.
( Example )
The maximum flow rate is constant
regardless of 50 Hz or 60 Hz and of
any voltage variants within the
serviceable voltage
50 Hz, At minimum serviceable voltage
(80% of rated voltage)
50 Hz, At rated voltage
60 Hz, At rated voltage
60 Hz, At minimum serviceable voltage
(90% of rated voltage)
26.4
26.4(11.4)
15.1(10.0)
Notes: 1. The relation between the maximum flow in the table above and the frequency/voltage (within the serviceable voltage) is as shown below.
The valve models with a mark are handled as
Options. If you choose such valves, check the time
of delivery beforehand.
For the maximum flow rate in P
2.
DSG-01 Series Solenoid Operated Directional Valves
350
5.8
4.5
19.8
18.5
7.7
6.1
6.3
5.0
17.4
15.3
2.1
6.3
5.0
1.3
6.3
5.0
7.1
5.8
3.4
13.2
2.6
26.4
26.4
21.1
23.8
22.5
13.3
10.8
26.4
22.5
26.4
22.5
19.8
18.5
21.1
18.5
DSG 01 3C2
DSG
01 3C3
DSG
01 3C4
DSG
01 3C40
DSG
01 3C60
DSG
01 3C9
DSG
01 3C10
DSG
01 3C11
DSG
01 3C12
DSG
01 2D2
DSG
01 2B2
DSG
01 2B3
DSG
01 2B8
26.4
14.5
20.6
18.5
26.4
16.4
22.5
17.2
17.4
15.3
5.3
26.4
19.6
6.1
26.4
19.6
11.9
5.3
13.2
6.9
7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3
2.6
9.5
7.4
3.4
9.5
7.4
10.6
7.9
4.2
13.2
3.4
6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3
2.6
7.4
5.3
2.6
7.4
5.3
7.9
6.6
4.0
13.2
2.9
26.4
14.5
20.6
18.5
26.4
16.4
22.5
17.2
17.4
15.3
5.3
26.4
19.6
26.4
22.5
26.4
19.6
13.2
12.2
8.5
19.8
17.2
14.0
9.3
26.4
26.4
21.1
23.8
22.5
13.3
10.8
26.4
22.5
26.4
22.5
19.8
18.5
21.1
18.5
26.4
26.4
21.1
23.8
11.1
17.2
11.9
13.3
10.8
26.4
22.5
9.2
26.4
22.5
9.2
19.8
18.5
21.1
18.5
26.4
26.4
21.1
13.2
6.9
10.6
7.9
13.3
10.8
26.4
21.1
6.1
26.4
21.1
6.1
19.8
18.5
21.1
18.5
26.4
26.4
21.1
10.0
5.3
8.7
6.9
13.3
10.8
26.4
10.6
5.3
26.4
10.6
5.3
19.8
18.5
21.1
18.5
11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3
4.0
14.8
11.4
5.3
14.8
11.4
11.9
4.2
13.2
4.5
11.9
9.3
20.6
18.5
15.3
12.7
13.7
9.5
17.4
15.3
4.0
14.8
11.4
15.9
12.2
14.8
11.4
13.2
13.2
8.2
6.1
19.8
17.2
9.2
7.9
7.4
6.1
20.6
18.5
10.0
7.9
7.9
6.6
17.4
15.3
2.6
9.5
7.4
10.6
8.5
9.5
7.4
13.2
11.1
6.3
5.0
19.8
17.2
6.1
4.5
6.6
5.0
20.6
18.5
8.2
6.6
6.9
5.6
17.4
15.3
2.6
7.4
5.3
9.5
7.4
7.4
5.3
11.9
10.6
5.8
4.8
19.8
17.2
5.0
3.4
5.8
4.5
19.8
18.5
7.7
6.1
6.3
5.0
17.4
15.3
2.1
6.3
5.0
8.5
6.3
6.3
5.0
11.9
10.6
5.8
4.8
19.8
17.2
4.5
3.2
P
A
T
B
P
A
T
B
P
A
T
B
a
b
PT
BA
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
a
b
AB
PT
b
AB
PT
b
AB
PT
b
AB
PT
[Port "A" Blocked][Port "B" Blocked]
Graphic
Symbols
Model
Numbers
Spool-Spring Arrangement
No. of Valve Positions
Max. Flow
Working Pressure PSI
Working Pressure PSI
Working Pressure PSI
U.S.GPM
Spring Centred
Three Positions
No-Spring
Detented
Spring Offset
Two Positions
List of Standard Models and The Maximum Flow
Models with DC or R Type Solenoids: DSG-01- -D /R
1450 2320 3630 4570 5080 1450 2320 3630 4570 5080 1450 2320 3630 4570 5080
T of the valves with a mark, please see page 351.
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
26.4
26.4
14.5
Notes: The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.1.
2.
The valve models with a mark are handled as
Options. If you choose suce valves, check the time
of delivery beforehand.
For the maximum flow rate in P
351
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
10 MPa
(1450 PSI)
55
(14.5)
16 MPa
(2320 PSI)
44
(11.6)
25 MPa
(3630 PSI)
30
(7.9)
31.5 MPa
(4570 PSI)
26
(6.9)
35 MPa
(5080 PSI)
22
(5.8)
63
(16.6)
63
(16.6)
40
(10.6)
40
(10.6)
32
(8.5)
25
(6.6)
a
b
AB
PT
P
A
T
B
P
A
T
B
P
A
T
B
a
b
PT
BA
a
b
AB
PT
b
AB
PT
Maximum Flow of Centre By-Pass
In valve type 3C60, in case where the actuator is put on in between the cylinder ports A and B as illustrated below and
where the actuator moves and suspended at its stroke end and where the valve is then shifted to the neutral position in
the suspended state of the actuator, the maximum flow rates available are those as shown as the table below regardless
of any voltage in the range of serviceable valtage.
Mode Numbers
Graphic
Symbol
Max. Flow L/min (U.S.GPM)
Max. Flow L/min (U.S.GPM)
DSG-01-3C60-A /D /R
List of Shockless Models and The Maximum Flow
Models with DC or R Type Solenoids: S-DSG-01- -D /R
[Port "B" Blocked]
[Port "A" Blocked]
Graphic
Symbol
Model Numbers
Spool-Spring
Arrangement
No. of
Valve
Positions
Three
Positions
Two
Positions
Spring
Centred
Spring
Offset
S-DSG-01-3C2
S-DSG-01-3C4
S-DSG-01-3B2
Working Pressure
MPa (PSI)
Working Pressure
MPa (PSI)
Working Pressure
MPa (PSI)
10
(1450)
16
(2320)
25
(3630)
10
(1450)
16
(2320)
25
(3630)
10
(1450)
16
(2320)
25
(3630)
40
(10.6)
32
(8.5)
50
(13.2)
40
(10.6)
40
(10.6)
20
(5.3)
25
(6.6)
40
(10.6)
32
(8.5)
16
(4.2)
40
(10.6)
32
(8.5)
16
(4.2)
32
(8.5)
20
(5.3)
16
(4.23)
32
(8.5)
20
(5.3)
16
(4.23)
32
(8.45)
16
(4.23)
12
(3.17)
50
(13.2)
45
(11.9)
45
(11.9)
45
(11.9)
40
(10.6)
40
(10.6)
32
(8.45)
16
(4.23)
12
(3.17)
30
(7.9)
30
(7.9)
30
(7.9)
60
(15.9)
60
(15.9)
40
(10.6)
40
(10.6)
( Example )
The maximum flow rate is constant
regardless of any voltage variants
within the serviceable voltage
At rated voltage
[after temperature rise and saturated]
At minimum serviceable voltage
(90% of rated voltage)
[after temperature rise and saturated]
60
(15.9)
50
(13.2)
40
(10.6)
Notes: The relation between the maximum flow in the table above and the voltage (within the serviceable voltage) is as shown be low.1.
U.S.GPM
L/min
DSG-01 Series Solenoid Operated Directional Valves
352
A
B
P
T
b
B
A
T
P
a
AB
P
T
b
B
A
T
P
a
DSG-01-2B B
DSG-01-2B2B
DSG-01-2B3B
DSG-01-2B4B
DSG-01-2B60B
DSG-01-2B10B
DSG-01-2B
A
DSG-01-2B2A
Model Numbers Model Numbers
Standard
Mtg. Type
Revers
e
Mtg. Type
Standard
Mtg. Type
Reverse
Mtg. Type
Graphic SymbolsG raphic Symbols
Reverse Mounting of Solenoid.
In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b position
(side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in the reverse
position -SOL a side- is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B A and 2B B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.
A
B
PT
b
B
A
TP
a
Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B A) and another
is the valve using the neutral position and SOL b position (2B B) .
Standard Mtg. of Solenoid Reverse Mtg. of Solenoid
(Example) In case of Spool Type "2"
A
P
T
a
b
A B
P T
b
A
B
P
T
b
"A": Use of Neutral and
SOL. a Energised
Position (2B2A)
SOL. a Energised
Position
2B2A
2B2B
SOL. b Energised
Position
Neutral Positio
n
"B": Use of Neutral and
SOL. b Energised
Position (2B2B
)
In the above table, the graphic symbols in mounting
type highlighted with shade are optional extra,
therefore, please confirm the time of delivery with
us before ordering.
SOL b SOL a
B
353
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
Type Model Numbers
1
T
2
T
Time ms
DSG-01-3C2- A
DSG-01-3C2- D
DSG-01-3C2- R
Standard
Type
15
48
50
23
19
100
Type Model Nmbers
1
T
2
T
Time
ms
1
G
2
G
Acceleratio
n
2
m/s (G)
12
(1.2
)
18
(1.8
)
7
(0.7
)
15
(1.5
)
30
25
70
35
S-DSG-01-3C2- D
DSG-01-3C2- D
Shockles
s
Type
Standard
Type
T
Max.
OF F O FF
ON
0
0
Solenoid
Spool Shift
1
T
2
a
b
Ps
Speed
Load
Accelmeter
ON
OF F
G
SOL a
Acceleration
(G)
(Ps)
Pressure
Time
1
G
2
T
1
T
2
Typical Changeover Time
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
16 MPa (2320 PSI)
31.5 L /min (8.3 U.S.GPM)
2
35 mm /s (164 SSU)
100 %V
(After coil temprature rises and saturated)
[Test Conditions
]
Standard Type
(Without Shockless Function)
Pressure:
Flow Rate:
Viscosity:
Voltage:
Shockless Type
[Test Circuit and Conditions]
Setting Pressure (Ps): 7 MPa (1020 PSI)
Load (W): 1000 kg (2205 1bs.)
Speed: 8 m/min (26.2 ft./min)
2
Viscosity: 35 mm /s (164 SSU )
[Reaults of Measurement]
[Result of Measurement]
DSG-01 Series Solenoid Operated Directional Valves
354
Model Numbers
P A
Pressure Drop Curve Number
4
5
4
4
1
5
4
4
4
5
5
5
5
DSG-01-3C2
DSG-01-3C3
DSG-01-3C4
DSG-01-3C40
DSG-01-3C60
DSG-01-3C9
DSG-01-3C10
DSG-01-3C11
DSG-01-3C12
DSG-01-2D2
DSG-01-2B2
DSG-01-2B3
DSG-01-2B8
4
5
4
4
1
3
5
4
4
4
4
5
4
5
4
4
1
5
4
4
4
5
5
5
4
4
5
4
4
1
3
4
4
5
4
4
5
2
2
Model Numbers
Pressure Drop Curve Number
1
1
1
2
1 1
1
2
1
S-DSG-01-3C2
S-DSG-01-3C4
S-DSG-01-2B2
11
1
Viscosity
SSU
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23 1.27 1.30
77 98 141 186 232 278 324 371 417 464
2
mm /s 15 20 30 40 50 60 70 80
90 100
B T
P B
A T
P T
P A
B
TP
BA
T
Pressure Drop
P
Flow Rate
Flow Rate
Pressure Drop P
2
Pressure drop curves based on viscosity of 35 mm /s (164 SSU) and specific gravity of 0.850.
Shockless Type: S-DSG-01
Standard Type: DSG-01
Pressure Drop
For any other viscosity, multiply the factors in the table below.
For any other specific gravity (G'), the pressure drop ( P') may be
obtained from the formula below.
P' = P (G'/0.850)
0
0 4 8 12 16 20 24 U.S.GPM
L/min
20 40 60 80 100
2
1
3
4
1
2
3
4
5
0
100
200
300
400
500
600
PSI
MPa
0
0
40
80
120
160
180
PSI
MPa
0246810121416
U.S.GPM
L/min
10 20 30 40 50 60
1.2
1.0
0.8
0.6
0.4
0.2
2
1
355
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
Mounting Surface
(O-Rings Furnished)
Lock Nut
Tightening Torque:
10.3-11.3
Nm (
91-100
IN.lbs.)
Manual Actuator-Both Ends
Locating pin can be fitted to this hole to conform with
ISO4401-03-02-94. However, locating pin is not provided
to standard design valve. When ordering valve with a
locating pin, please consult Yuken.
6(.24)
Dia.
3(.12)
Dia.
5(.20)
VIEW ARROW X
Deep
Electrical Conduit Connection
"C "
Thd. (Both Ends)
Model Numbers
DSG-01- -A -7
0
DSG-01- -A -7090
"C
"
Thd.
G 1/2
1/2 NP
T
Spring Centred
No-Spring Detented
Spring Offset
Models with DC Solenoids: (S-)DSG-01- -D -70/7090
Models with R Type Solenoids: (S-)DSG-01- -R -70/7090
Space Needed to Remove
Solenoid-Each End
Spring Offset Type
Double Solenoid
Models Only
For other dimensions, refer to models with AC solenoids.
DIMENSIONS IN
MILLIMETRES (INCHES)
Mounting surface: ISO 4401-AB-03-4-A
TERMINAL BOX TYPE
Double Solenoid: Spring Centred & No-Spring Detented
Models with AC Solenoids
-A -70/7090DSG-01-
3C
2D2
Single Solenoid: Spring Offset
DSG-01-2B -A
-70/7090
For other dimensions, refer to "spring Centred and
No-Spring Detented" models.
Solenoid being mounted in the reverse position
SOL a side is also available.
Space Needed to Remove
Solenoid-Each En
d
76.7
(3.02)
40.5
(1.59)
31
(1.22)
32.5
(1.28)
0.75
(.03)
Tank Port "T"
Cylinder Port "B"
Solenoid Indicator Light
(For Sol b)
Solenoid Indicator Light
(For Sol a)
Cylinder Port "A"
Pressure Port "P"
5.5(.22)
Dia. Through
9.5(.37)
C' Bore
4 Places
142.2
(5.60)
145.7
(5.74)
SOL b
DSG-01 Series Solenoid Operated Directional Valves
356
Sub-plate
Model Numbers
Piping Size
"C"
Thd.
"D"
Thd.
"E"
mm(IN.)
DSGM-01-31
DSGM-01-3180
DSGM-01-3190
DSGM-01X-31
DSGM-01X-3180
DSGM-01X-3190
DSGM-01Y-31
DSGM-01Y-3190
Rc 1/8
1/8 BSP.F
1/8 NPT
Rc 1/4
1/4 BSP.F
1/4 NPT
Rc 3/8
3/8 NPT
M5
M5
No.10-24 UNC
M5
No. 10-24 UNC
12 (.47)
10 (.39)
12 (.47)
10 (.39)
10 (.39)
12 (.47)No.10-24 UNC
A
T
P
B
12.7(.50)
21.5
(.85)
30.2
(1.19)
40.5
(1.59)
14.2
(.56)
0.75
(.03)
15.5
(.61)
5.2
(.20)
25.8
(1.02)
31
(1.22)
31.75
(1.25)
8.5
(.33)
48
(1.89)
7.5
(.30)
63
(2.48)
71
(2.80)
85
(3.35)
7
(.28)
7 (.28) Dia. Through
11 (.43) Dia. Spotface
2 Places
7 (.28) Dia.
4 Places
"
D
" Thd.
"
E
" Deep
4 Places
15
(.59)
16
(.63)
32
(1.26)
11
(.43)
24
(.94)
37
(1.46)
12.5
(.49)
35.5
(1.40)
58.5
(2.30)
"
C
" Thd.
4 Places
Sub-plate : DSGM-01/01X/01Y-31/3180/3190
DIMENSIONS IN
MILLIMETRES (INCHES)
357
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
CDEFGH
196.4
(7.73)
76.7
(3.02)
88.5
(3.48)
53
(2.09)
27.5
(1.08)
39
(1.54)
204.4
(8.05)
80.7
(3.18)
99.5
(3.92)
64
(2.52)
27.5
(1.08)
39
(1.54)
204.4
(8.05)
80.7
(3.18)
102.5
(4.04)
57.2
(2.25)
34
(1.34)
53
(2.09)
ABCDE FH JKL
C
72.5
(2.85)
29.5
(1.16)
H
D
23.5
(.93)
F
E
G
46(1.81)
A100
SOLa SOL b
SOL b
A
E
H
F
SOL a
SOL b
J
K
D
27
L
C
A100
A
3
5
B
38
PLUG-IN CONNECTOR TYPE (N)
PLUG-IN CONNECTOR WITH INDICATOR LIGHT (N1)
Models with AC Solenoids: DSG-01- -A - -70/7090
Models with DC Solenoids: (S-)DSG-01- -D - -70/7090
Models with R Solenoids: (S-)DSG-01- -R -N-70/7090
N
N1
N
N1
DIMENSIONS IN
MILLIMETRES (INCHES)
Double Solenoid
Models Only
Lock Nut
Tightening Torque:
10.3 - 11.3 Nm (90 - 100 IN.lbs.)
Cable Departure
Cable Applicable:
Outside Dia.
....
8 - 10 mm (.31 - .39 in.)
Conductor Area
....
Not Exceeding 1.5 mm
2
(.0023 Sq. in.)
The position of the Plug-in connector can be changed as
illustrated below by loosening the lock nut. After
completion of the change, be sure to tighten the lock nut
with the torque as specified below.
Model Numbers
DSG-01- -A -N
(S-)DSG-01- -D -N
(S-)DSG-01- -R -N
For other dimensions, refer to "Terminal Box type" (Page 356).
Models with Push Button & Lock Nut
(S-)DSG-01- - -C
AC: 132.2(5.20)
DC/R: 136.2(5.36)
Lock Nut
Press the "Push Button" then turn "Lock Nut"
clockwise. The position of the "Push Button" is held.
Be sure to loosen "Lock Nut" fully before solenoid
is energised.
Push Button
Interchangeability in Installation Current and New Design
In ouder to achieve higher pressure, higher flow, lower pressure drop DSG-01 valves has been upgraded from the 60
design series to the 70 design series.
The figures in the table below are the comparison between the current and the new design valves.
Design Number
Flow Rate: 60 L/min (15.9 U.S.GPM), Viscosity: 30 mm
2
/s (141 SSU), Spool type "2" (Closed centre)
Max. Operating
Pressure
MPa (PSI)
Max. T-Line
Back Pres.
MPa (PSI)
Pressure Drop
MPa (PSI)
{PA}
Mass kg (lbs.)
Max. Flow
L/min
(U.S.GPM)
Max. Changeover
Frequency
Cycle/min (min
–1
)
3C /2D
2B
1.85(4.08)
2.2(4.85)
0.9(130)
1.0(145)
21(3050)
16(2320)
35(5080)
31.5(4570)
100(26.4)
63(16.6)
300
(R Type sol. Only 120)
1.4(3.09)
1.6(3.53)
New Design: 70
Current Design:
60
Specifications
Interchangeability in Installation
Interchangeability in installation in maintained though there are minor differences in demension as in the following table.
196.4
(7.73)
142.2
(5.60)
46
(1.81)
88.8
(3.50)
95
(3.74)
50.7
(2.00)
26
(1.02)
70
(2.76)
13.5
(.53)
70.5
(2.78)
191.4
(7.54)
142.7
(5.62)
48
(1.89)
90.3
(3.56)
90
(3.54)
50.7
(2.00)
23.5
(.93)
65
(2.56)
11
(.43)
72
(2.83)
204.4
(8.05)
146.2
(5.76)
46
(1.81)
88.8
(3.50)
95
(3.74)
54.7
(2.15)
26
(1.02)
70
(2.76)
13.5
(.53)
70.5
(2.78)
210
(8.27)
152
(5.98)
48
(1.89)
90.3
(3.56)
90
(3.54)
60
(2.36)
23.5
(.93)
65
(2.56)
11
(.43)
72
(2.83)
Coil Type
Design
Number
New Design
: 70
Current Design
: 60
New Design
: 70
Current Design
: 60
AC
DC
R
(1.06)
(1.50)
DSG-01 Series Solenoid Operated Directional Valves
358
3
3
1.
2.
3.
Type of
Electrical Conduit
Connection
Double Solenoid Type Single Solenoid Type
Terminal
Box Type
Plug-in
Connector
Type
Type of
Electrical Conduit
Connection
Electric Source
Terminal
Box Type
Plug-in
Connector
Type
AC DC AC
DC Rectified
1
1
3
2
2
3
SOL.
SOL
. SOL.
SOL.
SOL
.
SOL.
1
Ground
3
Power Supply
(For SOL.a
)
Indicator Light
SOL. bSOL.
a
3
Power Supply
(For SOL.b)
Indicator Light
1
Ground
2
Common Plate
Commo
n
Indicator Light
Ground
3
Power Suppl y
SOL. b
Ground
3
2-Power Suppl y
1-Power Suppl
y
Indicator Light
Indicator Light
Voltage-Surge
Suppressor
Indicator Light
Voltage-Surge
Suppressor
Rectifier
Circui
t
Power
Supply
Common
Ground
Power
Supply
Common
Ground
Power
Supply
Common
Ground
Indicator Light
(Integrated in "N1"
model only
)
1-Power
Supply
Ground
2-Power
Supply
1-Power
Supply
Ground
2-Power
Supply
Indicator Light
(Integrated in "N1"
model only
)
Voltage-Surge
Suppressor
(Circuit composed
in coil
)
1-Power
Supply
Ground
2-Power
Supply
Voltage-Surge
Suppressor
Rectifier
Circuit
Details of Receptacle
There are two grounding terminals. You can use either one.
If you do not need the common plate, remove it.
With DC solenoids, polarity is no question.
Electrical Circuit
Do not perform wiring while the power is on.
Doing so may result in electric shock, burns or death.
Make the wiring properly. Improper wiring will cause an
irregular movement of the machine, resulting in a grave
accident.
DANGER
359
DIRECTIONAL CONTROLS
DSG-01 Series Solenoid
Operated Directional Valves
E
DSG-01 Series Solenoid Operated Directional Valves
8
9
18
19
24
25
26
27
30
AS 568-026 (NBR, Hs70)
4
1
2
2
2
2
4
4
1
2
2
2
2
4
4
1
1
2
1
1
1
2
2
SOL a
SOL b
16 12
18
14
19
17
13
15
5
431 8 2 27 25 21 23 20 26 22
30
9
7
6
8
28
11
29 10
Valve Model Numbers
-DSG-01- - -70/7090
-DSG-01- - -N-70/7090
Seal Kit No.
KS-DSG-01-70
KS-DSG-01-N-70
O-Ring Details for Seal Kit
(4 Pcs.), & (2 Pcs., see above), (4 Pcs.)
8 9 25 27
(4 Pcs.), & (2 Pcs., see above)
8 9 25
When ordering the O-Rings, please specify the seal kit number from the table below.
List of Seals
-DSG-01- - -70/7090
Item
Name of Parts Part Numbers
Qty.
3C 2D
2B
Remarks
Included in Solenoid Ass'y (Item 11)
SO-NB-P18
SO-NA-P20
SO-NA-P4
1790S-VK418329-9
O-Ring
O-Ring
Packing
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Plug
SO-NB-A-012 (NBR, Hs90)
SO-NB-P18
1790S-VK421290-8
S6
Spring Offset type
24
Solenoid Ass'y, Coil, Receptacle and Connector Refer to page 360 for the details of these parts.
SOL a
SOL b
18
11 19
16
15 14
-DSG-01- - -N/N1-70/7090
List of Seals
DSG-01 Series Solenoid Operated Directional Valves
360
Valve Model Numbers
DSG-01- -A100-70
DSG-01- -A120-70
DSG-01- -A200-70
DSG-01- -A240-70
DSG-01- -D12-70
DSG-01- -D24-70
DSG-01- -D48-70
DSG-01- -R100-70
DSG-01- -R200-70
S-DSG-01- -D12-70
S-DSG-01- -D24-70
S-DSG-01- -D48-70
S-DSG-01- -R100-70
S-DSG-01- -R200-70
DSG-01- -A100-N-70
DSG-01- -A120-N-70
DSG-01- -A200-N-70
DSG-01- -A240-N-70
DSG-01- -D12-N-70
DSG-01- -D24-N-70
DSG-01- -D48-N-70
DSG-01- -R100-N-70
DSG-01- -R200-N-70
S-DSG-01- -D12-N-70
S-DSG-01- -D24-N-70
S-DSG-01- -D48-N-70
S-DSG-01- -R100-N-70
S-DSG-01- -R200-N-70
DSG-01- -A100-N1-70
DSG-01- -A120-N1-70
DSG-01- -A200-N1-70
DSG-01- -A240-N1-70
DSG-01- -D12-N1-70
DSG-01- -D24-N1-70
DSG-01- -D48-N1-70
S-DSG-01- -D12-N1-70
S-DSG-01- -D24-N1-70
S-DSG-01- -D48-N1-70
11
Solenoid Ass'y No.
20
Coil No.
13
Receptacle
Part No.
18
Connector Ass'y
Part No.
19
Connector Ass'y
Part No.
Remarks
SA1-100-70
SA1-120-70
SA1-200-70
SA1-240-70
SD1-12-70
SD1-24-70
SD1-48-70
SR1-100-70
SR1-200-70
SD1-12-S-70
SD1-24-S-70
SD1-48-S-70
SR1-100-S-70
SR1-200-S-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SR1-100-N-70
SR1-200-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70
SR1-100-S-N-70
SR1-200-S-N-70
SA1-100-N-70
SA1-120-N-70
SA1-200-N-70
SA1-240-N-70
SD1-12-N-70
SD1-24-N-70
SD1-48-N-70
SD1-12-S-N-70
SD1-24-S-N-70
SD1-48-S-N-70
C-SA1-100-70
C-SA1-120-70
C-SA1-200-70
C-SA1-240-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SD1-12-70
C-SD1-24-70
C-SD1-48-70
C-SR1-100-70
C-SR1-200-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SR1-100-N-70
C-SR1-200-N-70
C-SA1-100-N-70
C-SA1-120-N-70
C-SA1-200-N-70
C-SA1-240-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
C-SD1-12-N-70
C-SD1-24-N-70
C-SD1-48-N-70
R1-70
KR1-A-70
KR1-B-70
RR1-70
KR1-A-70
KR1-B-70
RR1-70
Terminal
Box
Type
Plug-in
Connector
Type
Plug-in
Connector
with
Indicator
Light
GDM-211-A-11
GDME-211-R-A-10
GDM-211-A-11
GDME-211-R-A-10
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDM-211-B-11
GDME-211-R-B-10
GDM-211-B-11
GDME-211-R-B-10
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
GDML-211-2-11
GDML-211-3-11
GDML-211-1-11
Note: T
he connector assembly is not included in the solenoid assembly.
Solenoid Ass'y, Coil, Receptacle and Connector Ass'y No.