DIRECTIONAL
CONTROLS
21
1.
2.
3.
Specifications
3
3
Specifications
Valve
Type
Max. Flow
L/min
(U.S.GPM)
Max.
Operating
Pressure
MPa(PSI)
Max. Pilot
Pressure
MPa(PSI)
Min
Required
Pilot Pres.
MPa(PSI)
Ext.Drain Int.Drain
Max. T-Line Back
Pressure
MPa(PSI)
AC DC R
Max. Change-
over Frequency
-1
min (Cycles/Min)
Approx.
Mass
kg(1bs.)
Model Numbers
DSHG-01-3C
-
-13/1380/1390
DSHG-01-2B
-
-13/1380/1390
DSHG-03-3C
-
-13/1390
DSHG-03-2N
-
-13/1390
DSHG-03-2B
-
-13/1390
(S-)DSHG-04-3C
-
-51/5190
(S-)DSHG-04-2N
-
-51/5190
(S-)DSHG-04-2B
-
-51/5190
(S-)DSHG-06-3C
-
-52/5290
(S-)DSHG-06-2N
-
-52/5290
(S-)DSHG-06-2B
-
-52/5290
(S-)DSHG-06-3H
-
-52/5290
(S-)DSHG-10-3C
-
-42/4290
(S-)DSHG-10-2N
-
-42/4290
(S-)DSHG-10-2B
-
-42/4290
(S-)DSHG-10-3H
-
-42/4290
40 (10.6)
160 (42.3)
300 (79.3)
500 (132)
1100 (291)
21 (3050)
25 (3630)
31.5 (4570)
31.5 (4570)
31.5 (4570)
21 (3050)
25 (3630)
25 (3630)
25 (3630)
21 (3050)
25 (3630)
21 (3050)
1.0 (150)
0.7 (100)
0.8 (120)
0.8 (120)
1.0 (150)
1.0 (150)
16 (2320)
16 (2320)
21 (3050)
21 (3050)
21 (3050)
16 (2320)
16 (2320)
16 (2320)
16 (2320)
16 (2320)
120
120
120
120
110
120
100
60
120
120
120
120
110
120
100
60
120
120
120
120
110
100
100
50
3.5 (7.7)
2.9 (6.4)
7.2(15.9)
7.2(15.9)
6.6(14.6)
8.8(19.4)
8.8(19.4)
8.2(18.1)
12.7 (28)
12.7 (28)
12.1 (27)
13.5 (30)
45.3(100)
45.3(100)
44.7 (99)
53.1(117)
Standard
Type
Shockless
Type
Model Numbers
Rated Flow
L/min (U.S.GPM)
Max. Pressure
MPa (PSI)
DSHF-10-

-
-27
DSHF-16-

-
-37
DSHF-24-

-
-28
DSHF-32-

-
-27
315 (83)
(132)
(317)
(634)
500
1200
2400
21 (3050)
No.4
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10
S-DSHG-04/06/10
Sub-plate Mounting
The maximum flow means the limited flow without inducing any
abnormality to the operation (changeover) of the valve. For details,
please refer to the "List of Standard Models and Maximum Flow" on
pages 9 to 13.
In case of internal drain type valve, the differential pressure between
pilot pressure and back pressure at tank port should be kept more than
the minimum pilot pressure.
The minimum pilot pressure for the valve with pilot piston is 1.8 MPa
(260 PSI).
Yuken can offer flanged connection valves described
below. Consult Yuken for the details.
DIRECTIONAL
CONTROLS
E
Solenoid Ratings / Sub-plates
Valve Type Electric source
Coil
Type
Frequency
(Hz)
Source Rating
Voltage (V)
Serviceable Range Inrush (A) Holding (A) Power (W)
Current & Power at Rated Voltage
100
100
110
120
200
200
220
240
12
24
48
100
200
50
60
50
60
50
60
50
60
50/60
A100
A120
A200
A240
D12
D24
D48
R100
R200
80 - 110
90 - 120
96 - 132
108 - 144
160 - 220
180 - 240
192 - 264
216 - 288
10.8 - 13.2
21.6 - 26.4
43.2 - 52.8
90 - 110
180 - 220
2.42
2.14
2.35
2.02
1.78
1.21
1.07
1.18
1.01
0.89
0.51
0.37
0.44
0.42
0.31
0.25
0.19
0.22
0.21
0.15
2.45
1.23
0.61
0.33
0.16
AC
DC (K Series)
AC DC Rectified (R)
Standard
Type
Shockless
Type
29
29
Valve
Model
Numbers
Japanese Standard "JIS"
Sub-plate
Model Numbers
Thread
Size
Approx.
Mass
kg (1bs.)
Sub-plate
Model Numbers
Thread
Size
Approx.
Mass
kg (1bs.)
European Design Standard
Sub-plate
Model Numbers
Thread
Size
Approx.
Mass
kg (1bs.)
N. American Design Standard
DSGM-01-30
DSGM-01X-30
DSGM-01Y-30
Rc 1/8
DSGM-03-40
DSGM-03X-40
DSGM-03Y-40
DHGM-03Y-10
DHGM-04-20
DHGM-04X-20
DHGM-06-50
DHGM-06X-50
DHGM-10-40
DHGM-10X-40
Rc 1/4
Rc 3/8
Rc 3/8
Rc 1/2
Rc 3/4
Rc 3/4
Rc 1/2
Rc 3/4
Rc 3/4
Rc 1
Rc 1-1/4
Rc 1-1/2
4.7
0.8
0.8
0.8
3.0
3.0
(10.4)
(1.8)
(1.8)
(1.8)
(6.6)
(6.6)
4.7 (10.4)
4.4 (9.7)
4.1 (9.0)
7.4 (16.3)
7.4 (16.3)
21.5 (47.4)
21.5 (47.4)
DSGM-01-3080
DSGM-01X-3080
DSGM-03-2180
DSGM-03X-2180
DSGM-03Y-2180
DHGM-03Y-1080
DHGM-04-2080
DHGM-04X-2080
DHGM-06-5080
DHGM-06X-5080
DHGM-10-4080
DHGM-10X-4080
1/8 BSP.F
1/4 BSP.F
3/8 BSP.F
1/2 BSP.F
3/4 BSP.F
3/4 BSP.F
1/2 BSP.F
3/4 BSP.F
3/4 BSP.F
1 BSP.F
1-1/4 BSP.F
1-1/2 BSP.F
0.8 (1.8)
0.8 (1.8)
3.0 (6.6)
3.0 (6.6)
4.7 (10.4)
4.4 (9.7)
4.1 (9.0)
8.5 (18.7)
8.5 (18.7)
4.7 (10.4)
21.5 (47.4)
21.5 (47.4)
DSGM-01-3090
DSGM-01X-3090
DSGM-01Y-3090
DSGM-03-2190
DSGM-03X-2190
DSGM-03Y-2190
DHGM-03Y-1090
DHGM-04-2090
DHGM-04X-2090
DHGM-06-5090
DHGM-06X-5090
DHGM-10-4090
DHGM-10X-4090
1/8 NPT
1/4 NPT
3/8 NPT
3/8 NPT
1/2 NPT
3/4 NPT
3/4 NPT
1/2 NPT
3/4 NPT
3/4 NPT
1 NPT
1-1/4 NPT
1-1/2 NPT
0.8 (1.8)
0.8 (1.8)
3.0 (6.6)
3.0 (6.6)
4.7 (10.4)
4.4 (9.7)
4.1 (9.0)
7.4 (16.3)
7.4 (16.3)
4.7 (10.4)
21.5 (47.4)
21.5 (47.4)
0.8 (1.8)
DSHG-01
DSHG-03
DSHG-04
DSHG-06
DSHG-10
o
No.5
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10
S-DSHG-04/06/10
Solenoid Ratings
Inrush current in the above table show rms values at maximum stroke.
The coil type numbers in the shaded column are handled as optional extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
Sub-plates
DSGM-03
is available only for Internal pilot-Internal drain type (Use DHGM-03Y for other valves).
Sub-plates are available. Specify the sub-plate model number from the table above.
When sub-plates are not used, the mounting surface should have a good machined finish.
CSA Approved Solenoid Valve
The "DSHG" series valve have been approved by the
CSA(Candian Standards Association). consult us for details.
DIRECTIONAL
CONTROLS
1
1
1
1
1
1
2
2
2
2
2
2
5
4
1.
2.
3.
4.
5.
Model Number Designation
3
F-
S- DSHG -06
-2 B 2
A
-C2
-E
T -R2 -A100
-C -H
-N
-52 -L
-
Design
Standard
Models with
Reverse Mtg.
of Solenoid
Design
Number
Type of Elec-
trical Conduit
Connection
Bult-in
Orifice for
Pilot Line
Manual
Override of
Pilot Valve
Coil
Type
Spool Control
Modification
(Omit if not required)
Special
Seals
Type
Drain
Connec-
tion
Pilot
Connec-
tion
Models with
Pilot Choke
Valve
Special Two
Position
Valve
Spool
Type
Spool-Spring
Arrangement
No. of
Valve
Position
Valve
Size
Series
Number
F:
For
Phos-
phate
Ester
Type
Fluids
None:
Stand-
ard
Type
S:
Shock-
less
Type
None:
Stand-
ard
Type
DSGH:
Solenoid
Controlled
Pilot
Operated
Direction-
al Valve,
Sub-plate
Mounting
01
03
04
06
10
3
2
3
2
3
2
3
2
C:
Spring
Centred
B:
Spring
Offset
N:
No-Spring
C:
Spring
Centred
B:
Spring
Offset
N:
No-Spring
C:
Spring
Centred
B:
Spring
Offset
N:
No-Spring
C:
Spring
Centred
B:
Spring
Offset
H:
Pressure
Centred
2, 3, 4
40, 5, 60
7, 9, 10
11, 12
2, 3, 4
40, 7
2, 3, 4
40, 5, 60
7, 9, 10
11, 12
2
3
4
40
7
None:
Internal
Pilot
E:
External
Pilot
None:
External
Drain
T:
Internal
Drain
L
(Omit if not required)
L
(Omit if not required)
L
(Omit if not required)
L
(Omit if not required)
None:
Japanese
Standard
"JIS"
90:
N.
American
Design
Standard
None:
Japanese
Standard
"JIS" &
European
Design
Standard
90:
N.
American
Design
Standard
80:
European
Design
Standard
(Applicable
only for
DSHG-01)
13
13
51
52
42
None:
Terminal
Box Type
N:
Plug-in
Connector
Type
N1:
Plug-in
Connector
with
Indicator
Light
H:
Refer to
None:
Manual
Override
Pin
C:
Push
Button &
Lock Nut
AC:
A100 , A200
A120 , A240
DC:
D12 , D24
D48
AC
o
DC
R100 , R200
AC:
A100 , A200
A120 , A240
DC:
D12 , D24
D48
AC
o
DC
R100 , R200
R2:
With Stroke
Adjustment,
Both Ends
RA:
With Stroke
Adjustment,
Port "A" End
RB:
With Stroke
Adjustment,
Port "B" End
R2:
With Stroke Adj.,
Both Ends
RA:
With Stroke Adj.,
Port "A" End
RB:
With Stroke Adj.,
Port "B" End
P2:
With Pilot Piston,
Both Ends
PA:
PB:
With Pilot Piston,
Port "A" End
With Pilot Piston,
Port "B" End
Omit if not
required
A B
(Omit if not required)
C1:
With C1
Choke
C2:
With C2
Choke
C1C2:
With C1 &
C2 Choke
Omit if not
required
A
(Omit if not required)
A B
(Omit if not required)
2, 4, 40
60, 10, 12
3, 5, 6
7, 9, 11
2, 4, 40
(3, 7)
2, 4, 40
(3, 7)
2, 4, 40
(3, 7)
2, 4, 40
(3, 7)
2, 4, 40
60, 10, 12
3, 5, 6
7, 9, 11
A
(Omit if not required)
Pilot Connection
Internal Pilot
External Pilot (E)
Drain Connection
External Drain
Internal Drain (T)
External Drain
Internal Drain (T)
Care in Application
Hold back pressure in the tank line so that the difference
between pilot pressure and drain pressure is always
more than minimum required pilot pressure.
Combination is not applicable
No restrictions in the combination on us
Solenoid Controlled Pilot Operated
Directional Valves
No.6
DSHG-01 / 03 / 04 / 06 / 10
S-DSHG-04 / 06 / 10
Model Number Designation
Shckless type (S-DSHG) are not available for spool type marked ( ).
In spool-spring arrangement "H" (Pressure centred models), the valves with stroke adjustment
(R
) and pilot-piston (P
) are not available.
N1 stands for Plug-in connector with solenoid indicator light. N1 is not available for R-type
solenoids.
In spool-spring arrangement "H" (Pressure centred models), in case the pilot pressure is more than
10 MPa (1450 PSI), please specify that the valve should have the built-in orifice to the pilot line.
Note : In spool type "3", "5", "6", "60", and "7", the combination applicable between pilot system and
drain system is as described in the table below.
As for the details of the valve using the neutral position and the side position (either SOL a or
SOL b side), please refer to page 14. Furthermore, the spool types other than "2", "4", "40" (3, 7)
are also available.
In the table above, the symbols and numbers highlighted with shade represent the optional extras.
The valves with model number having such optional extras are handles as options, therefore please
confirm the time of delivery with us before ordering.
DIRECTIONAL
CONTROLS
1.
3
1
2
1
2
2.
3.
E
Mounting Bolt
Model
Numbers
Name
Japanese Standard "JIS"
European Design Standard
N. American Design Standard Qty.
Tightening Torque
Nm (in. 1bs.)
Mouting Bolt
Mtg. Bolt Kit
Soc. Hd. Cap Screw
Soc. Hd. Cap Screw
Soc. Hd. Cap Screw
Soc. Hd. Cap Screw
DSHG-01
DSHG-03
(S-)DSHG-04
(S)-DSHG-06
(S)-DSHG-10
MBK-01-01-30
MBK-01-02-30
M6
u
35 Lg.
M6
u
45 Lg.
M10
u
50 Lg.
M12
u
60 Lg.
M20
u
75 Lg.
MBK-01-01-3090
MBK-01-02-3090
1/4-20 UNC
u
1-3/4 Lg.
1/4-20 UNC
u
1-3/4 Lg.
3/8-16 UNC
u
2 Lg.
1/2-13 UNC
u
2-1/2 Lg.
3/4-10 UNC
u
3 Lg.
1 set
4
2
4
6
6
5
12
12
58
100
473
-
-
-
-
-
-
6
15
15
72
123
585
(43
(104
(104
(504
(868
(4106
-
-
-
-
-
-
52)
130)
130)
625)
1068)
5078)
Model Numbers
MBK-01-01-30
MBK-01-02-30
MBK-01-01-3090
MBK-01-02-3090
(
(
(
(
94
134
94
134
)
)
)
)
3.70
5.28
3.70
5.28
A
mm (In.) "
B
" Thd.
M5
No.10-24 UNC
8.5
Dia.
(.33)
9
(.35)
A
9
(.35)
"
B
" Thd.
9
(.35)
15
(.59)
4
(.16)
"
B
" Thd.
Both Ends
No.7
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10
S-DSHG-04/06/10
For Internal Pilot-Internal Drain.
Mounting Bolt
For External Pilot or External Drain.
Mounting bolt kit is common to that of 01 series modular valves.
Refer to figure below for the dimensions of bolt kit.
Stud Bolt
Nut
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
Options
(.7)
(1.1)
(1.3)
(4.1)
C1, C2 C1C2 P2
PA
PB
P2
PA
PB
Model with Pilot
Choke Adj.
Models with
Pilot Piston
Models with
Stroke Adj.
Model
Numbers
DSHG-03
(S-)DSHG-04
(S-)DSHG-06
(S-)DSHG-10
0.65(1.4)
0.65(1.4)
0.65(1.4)
0.65(1.4)
1.3(2.9)
1.3(2.9)
1.3(2.9)
1.3(2.9)
1.0(2.2)
3.6(7.9)
0.5(1.1)
1.8(4.0)
0.6(1.3)
1.0(2.2)
1.2(2.6)
3.7(8.2)
0.3
0.5
06
1.85
kg (1bs.)
ba
P
Y
AB
T
b
a
P
Y
A
B
T
A
B
P
T
a
Y
b
V
W
A
B
P
T
a
Y
b
V
A
B
P
T
a
Y
b
W
Choke
C2
Choke
C1
Choke
C2
Choke
C1
AB
PT
Y
V
X
b
a
A
B
P
T
V
X
b
a
Y
A
B
P
T
b
a
Y
A
B
P
T
b
a
Y
A
B
P
T
b
a
Y
No.8
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04/06/10
S-DSHG-04/06/10
Models with Pilot Choke Adjustment
Options
When the adjustment screw is turned clockwise,
changeover speed of the main spool becomes slow. In
case of the spring centred valves in particular, making
slow of the returning speed of the main spool to the
neutral position is possible with a C2 choke valve.
These choke valves can be used in combination with the
valves of spring centred, no-spring, offset, pressure
centred and the valves with stroke adjustment.
Models with Pilot Piston(P2, PA, PB)
The valves with a pilot piston can be used when the high
speed changeover of the main spool is required.
However, please not that in case of spring centered
valves, there is no change in the returning speed of the
main spool to the neutral position even with the pilot
piston.
Graphic Symbols (Ex.: Spring Centred)
"PB" Models
Graphic Symbols (Ex.: Spring Centred)
DSHG-01,06,10
DSHG-03, 04
"PA" Models
"P2" Models
Pressure Centred Models (3H
)
The pressure centered type can be used when the
returning of the main spool to the neutral position is
required to be firmily.
Models with Stroke Adjustment (R2, RA, RB)
When the adjustment screw is screwed in , the main
spool stroke becomes short and flow rate reduces.
"RB" Models
"RA" Models
"R2" Models
Graphic Symbols (Ex.: Spring Centred)
Graphic Symbols (Ex.: External Pilot-External Drain)
(Only for 3H6, 3H60)
Additional Mass of Options
Add the mass described below to the mass of standard
models on page 4, if options are required.
Options on Pilot Valve
The same options to DSG-01 series valves are available.
Please refer to the Catalogue No. Pub. EC-0402 for the
details.
DIRECTIONAL
CONTROLS
E
List of Standard Models and Maximum Flow
b
AB
PT
Y
P
TY
a
b
A
B
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
DSHG-01-3C2
DSHG-01-3C3
DSHG-01-3C4
DSHG-01-3C40
DSHG-01-3C5
DSHG-01-3C60
DSHG-01-3C7
DSHG-01-3C9
DSHG-01-3C10
DSHG-01-3C11
DSHG-01-3C12
DSHG-01-2B2
DSHG-01-2B3
DSHG-01-2B4
DSHG-01-2B40
DSHG-01-2B7
"2"
"3"
"4"
"40"
"5"
"60"
"7"
"9"
"10"
"11"
"12"
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6)
40 (10.6) 40 (10.6) 40 (10.6)
7 MPa
(1020 PSI)
14 MPa
(2030 PSI)
21 MPa
(3050 PSI)
7 MPa
(1020 PSI)
14 MPa
(2030 PSI)
21 MPa
(3050 PSI)
Model Numbers Model Numbers
Graphic Symbol Graphic Symbol
Maximum Flow
L/min (U.S.GPM)
Maximum Flow
L/min (U.S.GPM)
Spring Centred Spring Centred
Three Positions Two Positions
Spool Type
No.9
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01
A
P
T
B
b
a
Notes ) Max. flow shows value at pilot pressure more than 1 MPa (150 PSI)1.
Max. flow in the table above represents the value in the flow condition of P
o
A
o
B
o
T (or P
o
B
o
A
o
T) as shown in the circuit diagram right.
In case the valve is used in the condition that either A or B port is blocked, the maximum flow differs
according to a hydraulic circuit, therefore, please consult us for details.
2.
DIRECTIONAL
CONTROLS
List of Standard Models and Maximum Flow
b
AB
PT
Y
b
A
B
P
T
Y
a
PT
Y
a
b
AB
DSHG-03-2N2
DSHG-03-2N3
DSHG-03-2N4
DSHG-03-2N40
DSHG-03-2N7
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
DSHG-03-2B2
DSHG-03-2B3
DSHG-03-2B4
DSHG-03-2B40
DSHG-03-2B7
"2"
"3"
"4"
"40"
"7"
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
7 MPa
(1020 PSI)
14 MPa
(2030 PSI)
25 MPa
(3630 PSI)
Model Numbers
Maximum Flow
L/min (U.S.GPM)
No-Spring
Spool Type
7 MPa
(1020 PSI)
14 MPa
(2030 PSI)
25 MPa
(3630 PSI)
Maximum Flow
L/min (U.S.GPM)
Model Numbers
Graphic Symbol Graphic Symbol
Spring Offset
DSHG-03-3C2
DSHG-03-3C3
DSHG-03-3C4
DSHG-03-3C40
DSHG-03-3C5
DSHG-03-3C60
DSHG-03-3C7
DSHG-03-3C9
DSHG-03-3C10
DSHG-03-3C11
DSHG-03-3C12
7 MPa
(1020 PSI)
14 MPa
(2030 PSI)
25 MPa
(3630 PSI)
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Spring Centred
Spool Type
Graphic Symbol
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
160 (42.3)
"2"
"3"
"4"
"40"
"5"
"60"
"7"
"9"
"10"
"11"
"12"
85
160
(22.5)
(42.3)
85
160
85
160
85
160
85
160
85
160
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
85
160
85
160
85
160
85
160
85
160
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
85
160
85
160
85
160
85
160
85
160
85
160
85
160
85
160
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
(22.5)
(42.3)
125
160
60
95
60
95
60
95
60
95
60
95
(33.0)
(42.3)
(15.9)
(25.1)
(15.9)
(25.1)
(15.9)
(25.1)
(15.9)
(25.1)
(15.9)
(25.1)
60
95
(15.9)
(25.1)
60
95
60
95
(15.9)
(25.1)
(15.9)
(25.1)
60
95
(15.9)
(25.1)
160 (42.3) 160 (42.3)
160 (42.3)
No.10
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-03
Three Positions
Two Positions
A
P
T
B
b
a
85 (22.5)
160 (42.3)
160 (42.3)
Notes: The relation between max. flow and pilot pressure in the table
above is as shown below.
1.
2.
(Example)
Maximum flow rate is constant regardless of pilot pressure.
Pilot Pressure more than 0.7 MPa (100 PSI).
Pilot Pressure at 0.7 MPa (100 PSI).
Pilot Pressure at 1 MPa (150 PSI).
Max. flow in the table above represents the value in the flow
condition of P
o
A
o
B
o
T (or P
o
B
o
A
o
T) as shown
in the circuit diagram right.
In case the valve is used in the condition that either A or B port
is blocked, the maximum flow differs according to a hydraulic
circuit, therefore, please consult us for details.
DIRECTIONAL
CONTROLS
E
List of Standard Models and Maximum Flow
b
A
B
P
T
Y
a
b
AB
PT
Y
PT
Y
a
b
AB
DSHG-04-2N2
DSHG-04-2N3
DSHG-04-2N4
DSHG-04-2N40
DSHG-04-2N7
DSHG-04-2B2
DSHG-04-2B3
DSHG-04-2B4
DSHG-04-2B40
DSHG-04-2B7
"2"
"3"
"4"
"40"
"7"
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
Maximum Flow
L/min (U.S.GPM)
No-Spring
Spool Type
Model Numbers
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)
Model Numbers
Graphic Symbol
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
Maximum Flow
L/min (U.S.GPM)
Spring Offset
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Spool Type
Graphic Symbol
Spring Centred
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
(S-)
DSHG-04-3C2
DSHG-04-3C2
(S-)
(S-)
DSHG-04-3C4
DSHG-04-3C4
DSHG-04-3C40
DSHG-04-3C40
DSHG-04-3C3
DSHG-04-3C5
DSHG-04-3C6
(S-)
DSHG-04-3C60
DSHG-04-3C60
DSHG-04-3C7
DSHG-04-3C9
(S-)
DSHG-04-3C10
DSHG-04-3C10
(S-)
DSHG-04-3C12
DSHG-04-3C12
DSHG-04-3C11
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
250 (66.1)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3)
300 (79.3) 300 (79.3) 300 (79.3)
250 (66.1)
300 (79.3)
300 (79.3)
300 (79.3)
250 (66.1)
250 (66.1)
140 (37.0)
200 (52.8)
120 (31.7)
165 (43.6)
110 (29.1)
145 (38.3)
110 (29.1)
260 (68.7)
245 (64.7) 245 (64.7)
245 (64.7)
300 (79.3) 300 (79.3)
235 (62.1)
200 (52.8) 145 (38.3)
250 (66.1)280 (74.0)
260 (68.7) 160 (42.3) 140 (37.0)
280 (74.0)
250 (66.1)
170 (44.9)
120 (31.7)
135 (35.7)
110 (29.1)
300 (79.3)
250 (66.1)
200 (52.8)
120 (31.7)
150 (39.6)
110 (29.1)
300 (79.3)
250 (66.1)
200 (52.8)
120 (31.7)
145 (38.3)
110 (29.1)
Graphic Symbol
No.11
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-04 / S-DSHG-04
Notes: Max flow described above shown value at pilot pressure more than 0.8 MPa (120 PSI).1.
A
P
T
B
b
a
Two Positions
Three Positions
Max. flow in the table above represents the value in the flow condition of P
o
A
o
B
o
T (or
P
o
B
o
A
o
T) as shown in the circuit diagram right.
In case the valve is used in the condition that either A or B port is blocked, the maximum flow
differs according to a hydraulic circuit, therefore, please consult us for details.
2.
DIRECTIONAL
CONTROLS
List of Standard Models and Maximum Flow
b
A
B
P
T
Y
a
b
AB
PT
Y
PT
Y
a
b
AB
P
T
Y
a
b
A
B
V
"2"
"3"
"4"
"40"
"7"
Maximum Flow
L/min (U.S.GPM)
No-Spring
Spool Type
Graphic Symbol
DSHG-06-2N2
DSHG-06-2N3
DSHG-06-2N4
DSHG-06-2N40
DSHG-06-2N7
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
(S-)
(S-)
(S-)
Model Numbers
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
DSHG-06-2B2
DSHG-06-2B3
DSHG-06-2B4
DSHG-06-2B40
DSHG-06-2B7
Model Numbers
(S-)
(S-)
(S-)
Maximum Flow
L/min (U.S.GPM)
Spring Offset
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
Graphic Symbol
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Spool Type
Graphic Symbol
Spring Centred
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
(S-)DSHG-06-3C2
DSHG-06-3C3
DSHG-06-3C4
DSHG-06-3C40
DSHG-06-3C5
DSHG-06-3C6
DSHG-06-3C60
DSHG-06-3C7
DSHG-06-3C9
DSHG-06-3C10
DSHG-06-3C11
DSHG-06-3C12
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Graphic Symbol
Pressure Centred
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)DSHG-06-3H2
DSHG-06-3H3
DSHG-06-3H4
DSHG-06-3H40
DSHG-06-3H5
DSHG-06-3H6
DSHG-06-3H60
DSHG-06-3H7
DSHG-06-3H9
DSHG-06-3H10
DSHG-06-3H11
DSHG-06-3H12
(S-)
(S-)
(S-)
(S-)
(S-)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
475 (125)
475 (125)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
390 (103)
420 (111)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
500 (132)
425 (112)
300 (79.3)
340 (89.8)
450 (119)
350 (92.5)
230 (60.8)
280 (74.0)
360 (95.1)
460 (122) 370 (97.8) 500 (132)
500 (132)
500 (132)
410 (108)
500 (132)
310 (81.9)
500 (132)
310 (81.9)
500 (132)
310 (81.9)
500 (132)
410 (108)
500 (132)
410 (108)
500 (132)
450 (119)
500 (132)
410 (108)
500 (132)
410 (108)
500 (132)
410 (108)
500 (132)
360 (95.1)
500 (132)
310 (81.9)
500 (132)
310 (81.9)
500 (132)
310 (81.9)
500 (132)
460 (122)
500 (132)
460 (122)
500 (132)
460 (122)
500 (132)
420 (111)
500 (132)
420 (111)
500 (132)
470 (124)
500 (132)
420 (111)
500 (132)
420 (111)
500 (132)
420 (111)
500 (132)
No.12
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-06 / S-DSHG-06
A
P
T
B
b
a
410 (108)
500 (132)
500 (132)
Notes: The relation between max. flow and pilot pressure in the table above is as shown
below.
1.
2.
(Example)
Maximum flow rate is constant regardless of pilot pressure.
Pilot Pressure more than 0.8 MPa (120 PSI).
In case pressure centred models, pilot pressure is more than
1 MPa (150 PSI).
Pilot Pressure at 0.8 MPa (120 PSI).
In case pressure centred models, pilot pressure
is more than 1 MPa (150 PSI)
Pilot Pressure at 1.5 MPa (220 PSI).
Two Positions
Three Positions
Max. flow in the table above represents the value in the flow condition of P
o
A
o
B
o
T (or P
o
B
o
A
o
T) as shown in the circuit diagram right.
In case the valve is used in the condition that either A or B port is blocked, the
maximum flow differs according to a hydraulic circuit, therefore, please consult us
for details.
DIRECTIONAL
CONTROLS
E
List of Standard Models and Maximum Flow
Two Positions
b
A
B
P
T
Y
a
b
AB
PT
Y
PT
Y
a
b
AB
P
T
Y
a
b
A
B
V
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Spool Type
Graphic Symbol
Spring Centred
10 MPa
(1450 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
Model Numbers
Maximum Flow
L/min (U.S.GPM)
Graphic Symbol
Pressure Centred
"2"
"3"
"4"
"40"
"5"
"6"
"60"
"7"
"9"
"10"
"11"
"12"
(S-)DSHG-10-3C2
DSHG-10-3C3
DSHG-10-3C4
DSHG-10-3C40
DSHG-10-3C5
DSHG-10-3C6
DSHG-10-3C60
DSHG-10-3C7
DSHG-10-3C9
DSHG-10-3C10
DSHG-10-3C11
DSHG-10-3C12
(S-)
(S-)
(S-)
(S-)
(S-)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1050 (277)
1050 (277)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
(S-)DSHG-10-3H2
DSHG-10-3H3
DSHG-10-3H4
DSHG-10-3H40
DSHG-10-3H5
DSHG-10-3H6
DSHG-10-3H60
DSHG-10-3H7
DSHG-10-3H9
DSHG-10-3H10
DSHG-10-3H11
DSHG-10-3H12
(S-)
(S-)
(S-)
(S-)
(S-)
950 (251)
1100 (291)
"2"
"3"
"4"
"40"
"7"
Maximum Flow
L/min (U.S.GPM)
No-Spring
Spool Type
Graphic Symbol
DSHG-10-2N2
DSHG-10-2N3
DSHG-10-2N4
DSHG-10-2N40
DSHG-10-2N7
(S-)
(S-)
(S-)
Model Numbers
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
DSHG-10-2B2
DSHG-10-2B3
DSHG-10-2B4
DSHG-10-2B40
DSHG-10-2B7
Model Numbers
(S-)
(S-)
(S-)
Maximum Flow
L/min (U.S.GPM)
Spring Offset
16 MPa
(2320 PSI)
25 MPa
(3630 PSI)
31.5 MPa
(4570 PSI)
Graphic Symbol
10 MPa
(1450 PSI)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
880 (232)
940 (248)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
750 (198)
1100 (291)
1060 (280) 895 (236)
950 (251)
1100 (291)
950 (251)
1100 (291)
750 (198)
1100 (291)
750 (198)
1100 (291)
980 (259)
700 (185)
785 (207)
850 (225)
570 (151)
680 (180)
1040 (275)
1100 (291)
870 (230)
1100 (291)
950 (251)
1100 (291)
950 (251)
1100 (291)
950 (251)
1100 (291)
1040 (275) 870 (230)
750 (198)
1100 (291)
750 (198)
1100 (291)
750 (198)
1100 (291)
1060 (280)
1100 (291)
1060 (280)
1100 (291)
1060 (280)
1100 (291)
1100 (291)
1100 (291)
970 (256)
1100 (291)
1050 (277)
1100 (291)
970 (256)
1100 (291)
970 (256)
1100 (291)
1000 (264)
1100 (291)
970 (256)
1100 (291)
970 (256)
1100 (291)
10 MPa
(1450 PSI)
10 MPa
(1450 PSI)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
1100 (291)
No.13
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-10 / S-DSHG-10
A
P
T
B
b
a
1040 (275)
1100 (291)
1100 (291)
Notes ) The relation between max. flow and pilot pressure in the table above
is as shown below.
1.
2.
(Example)
Maximum flow rate is constant regardless of pilot pressure.
Pilot Pressure more than 1 MPa (150 PSI).
Pilot Pressure at 1 MPa (150 PSI).
Pilot Pressure at 1.5 MPa (220 PSI).
Three Positions
Max. flow in the table above represents the value in the flow condition
of P
o
A
o
B
o
T (or P
o
B
o
A
o
T) as shown in the circuit
diagram right.
In case the valve is used in the condition that either A or B port is
blocked, the maximum flow differs according to a hydraulic circuit,
therefore, please consult us for details.
DIRECTIONAL
CONTROLS
Reverse Mtg. of Sol. / Special 2-Position Valve
A
B
T
P
Y
b
B
A
PT
Y
a
A
B
TP
Y
b
B
A
PT
Y
a
ab
Y
P
T
A
B
Standard
Mtg.
Reverse
Mtg. Type
Standard
Mtg.
Reverse
Mtg. Type
Standard
Mtg.
Graphic Symbols Graphic Symbols
Graphic
Symbols
Model Numbers Model Numbers Model Numbers
04
06
10
DSHG- -2B
A
04
06
10
DSHG- -2B
B
04
06
10
DSHG- -2N
A
DSHG-
-2B2A(S-)
DSHG-
-2B3A
DSHG-
-2B4A(S-)
DSHG-
-2B40A(S-)
DSHG-
-2B5A
DSHG-
-2B6A
DSHG-
-2B60A(S-)
DSHG-
-2B7A
DSHG-
-2B9A
DSHG-
-2B10A(S-)
DSHG-
-2B11A
DSHG-
-2B12A(S-)
DSHG-
-2B2B(S-)
DSHG-
-2B3B
DSHG-
-2B4B(S-)
DSHG-
-2B40B(S-)
DSHG-
-2B5B
DSHG-
-2B6B
DSHG-
-2B60B(S-)
DSHG-
-2B7B
DSHG-
-2B9B
DSHG-
-2B10B(S-)
DSHG-
-2B11B
DSHG-
-2B12B(S-)
DSHG-
-2N2A(S-)
DSHG-
-2N3A
DSHG-
-2N4A(S-)
DSHG-
-2N40A(S-)
DSHG-
-2N5A
DSHG-
-2N6A
DSHG-
-2N60A(S-)
DSHG-
-2N7A
DSHG-
-2N9A
DSHG-
-2N10A(S-)
DSHG-
-2N11A
DSHG-
-2N12A(S-)
Y
P
T
A
B
b
Y
T
P
B
A
a
SOL b
SOL a
Standard Mtg. of Solenoid Reverse Mtg. of Solenoid ("L")
No.14
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01 / 03 / 04 / 06 / 10
S-DSHG-04 / 06 / 10
A
B
PT
a
b
Y
A
B
P
Y
T
b
A
B
Y
PT
b
2B2A
2B2B
(Example) In case of Spool Type "2"
"A":
Use of Neutral and
SOL. a
Energised
Position
SOL. a
Energised
Position
SOL. b
Energised
Position
Neutral Position
"B":
Use of Neutral and
SOL. b
Energised
Position
Valves Using Neutral Position and Side Position. (Special Two position Valve)
Besides the use of the standard 2-position valves aforementioned in the "List of Standard Models and Maximum Flow",
the 3-position valves also can be used as the 2-position valves using the two of their three positions. In this case, there
are two kinds of the valve available. One is the valve using the neutral position and SOL a position (2B
A) and another
is the valve using the neutral position and SOL b position (2B
B).
Reverse Mounting of Solenoid.
In spring offset type, it is a standard configuration that the solenoid is mounted onto the valve in the SOL b
position (side). However, in this particular spool-spring arrangement, the mounting of the solenoid onto the valve in
the reverse position - SOL a side - is also available. The graphic symbol for this reverse mounting is as shown below.
As for the valve type 2B
A and 2B
B, please refer to the explanation under the heading of "Valves Using Neutral
Position and Side Position" given below.
DIRECTIONAL
CONTROLS
E
Preessure Drop
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
3
4
3
3
3
3
2
2
2
2
2
2
3
4
3
3
3
3
2
1
1
3
4
3
3
3
2
2
2
2
2
3
4
3
3
3
2
2
2
2
2
2
3
4
40
5
60
7
9
10
11
12
2
2
2
2
2
2
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
3
5
3
3
6
3
3
5
5
3
3
3
4
5
4
4
4
4
4
2
1
3
6
3
6
3
3
3
5
3
3
4
6
4
4
4
4
4
4
4
6
2
3
4
40
5
60
7
9
10
11
12
4
6
6
4
6
4
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
5
5
5
5
7
5
4
3
3
4
4
3
5
7
5
1
7
5
5
5
6
5
4
4
2
4
7
5
5
5
5
7
6
6
6
6
2
3
4
40
5
6
7
9
10
11
12
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
2
2
2
2
3
4
2
2
2
6
2
2
4
2
2
6
2
2
7
4
5
2
4
40
60
10
12
4
5
6
60
5
5
5
5
5
6
5
5
6
5
6 5 4 5 5
2
2
MPa
PSI
Pressure Drop P
L/min
U.S.GPM
Flow Rate
1
2
3
4
0
10
20
30
40
1.4
1.2
0.8
0.4
1.0
0.6
0.2
0
200
160
120
80
40
0
2468100
MPa
PSI
Pressure Drop P
L/min
U.S.GPM
Flow Rate
40
80
120
160
2.0
1.6
1.2
0.8
0.4
300
0
10 20 30 400
0
3
4
5
6
21
250
200
150
100
50
0
MPa
PSI
Pressure Drop P
L/min
U.S.GPM
Flow Rate
180
0
20 40 60 800
160
120
80
40
No.15
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01/03/04
S-DSHG-04
2
Pressure drop curves based on viscosity of 35 mm /s (164 SSU) and specific gravity of 0.850.
1
2
3
4
5
6
7
0
100
150
200
50
250
300
1.2
0.8
0.4
DSHG-01
DSHG-03
DSHG-04, S-DSHG-04
0
DSHG-01
DSHG-03
DSHG-04
S-DSHG-04
DIRECTIONAL
CONTROLS
Pressure Drop
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
8
6
8
8
8
5
5
4
5
5
4
3
8
6
8
8
5
5
4
1
1
6
6
6
8
8
5
4
5
5
4
6
6
6
8
5
7
2
3
4
40
5
6
7
9
10
11
12
7
60
8 5 8
1
7
7
7
7
4
7
7
7
7
7
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
6
6
8
1
2
5
6
6
8
6
8
8
2
5
5
6
8
8
3
2
4
40
10
12
2
60
1
2
7
7
7
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
9
7
9
9
9
5
6
6
6
6
6
3
9
7
9
9
8
5
5
1
2
8
7
7
9
9
5
6
6
5
6
8
7
7
9
8
5
2
3
4
40
5
6
7
9
10
11
12
8
60
9 7 9
3
7
6
8
6
2
7
8
8
7
6
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
Spool
Type
P A
o
B T
o
P B
o
A T
o
P T
o
Pressure Drop
Curve Numbers
8
8
9
3
5
6
8
8
9
8
9
9
4
5
7
8
9
9
4
2
4
40
10
12
4
60
2
6
8
8
6
Viscosity
SSU
Factor 0.81 0.87 0.96 1.03 1.09 1.14 1.19 1.23
77 98 141 186 232 278 324 371
2
mm /s 15 20 30 40 50 60 70 80
1.27
417
90
1.30
464
100
1
2
3
4
5
6
7
8
9
0
200 400
600
800
2.0
1.6
1.2
0.8
0.4
1
2
3
4
5
6
7
8
0
100
200
300
400
500
2.0
1.6
1.2
0.8
0.4
PSI
Pressure Drop P
L/min
U.S.GPM
Flow Rate
300
250
200
150
50
0
20 60 80 100 1200
0
14040
100
MPa
1000 1100
PSI
Pressure Drop P
L/min
U.S.GPM
Flow Rate
300
250
200
150
50
0
50 1500
300100
100
MPa
200 250
0
No.16
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-06, 10 / S-DSHG-06, 10
DSHG-06, S-DSHG-06
DSHG-10, S-DSHG-10
DSHG-06
S-DSHG-06
DSHG-10
S-DSHG-10
For any other viscosity, multiply the factors in the table below.
For any other specific gravity (G'), the pressure drop ( P') may be obtained
from the formula right.
P' = P(G'/0.850)
DIRECTIONAL
CONTROLS
E
Typical Changeover Time
Pilot Pressure
SOL"OFF"
SOL"ON"
3C
SOL"ON","OFF"
2B
2N
250
200
150
100
50
510
15 20
25
SOL"OFF"
SOL"ON"
3C
2N
SOL"ON"
2B
SOL"OFF"
150
100
50
510
15 20
25
SOL"OFF"
SOL"ON"
3C
2N
SOL"ON"
2B
SOL"OFF"
150
100
50
510
15 20
25
3000200010000
3600
MPa
PSI
ms
Changeover Time
0
0
Pilot Pressure
3000200010000
3600
MPa
PSI
ms
Changeover Time
0
0
Pilot Pressure
3000200010000
3600
MPa
PSI
Changeover Time
0
0
ms
No.17
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-04/06/10
Changeover time varies according to oil viscosity, spool type and hydraulic circuit.
DSHG-04
Test Conditions
Coil Type : D
(Models with DC solenoids)
Voltage : Rated Voltage
2
Oil Viscosity : 35 mm /s (164 SSU)
DSHG-10
DSHG-06
DIRECTIONAL
CONTROLS
Mounting surface: ISO 4401-AB-03-4-A
Installation Drawing
Sub-plate
Model Numbers
DSGM-01-30
DSGM-01-3080
DSGM-01-3090
DSGM-01X-30
DSGM-01X-3080
DSGM-01X-3090
DSGM-01Y-30
DSGM-01Y-3090
Piping Size
"
C
" Thd.
Rc 1/8
1/8 NPT
Rc 1/4
Rc 3/8
1/4 BSP.F
1/4 NPT
3/8 NPT
"
D
" Thd.
M5
No. 10-24 UNC
M5
No. 10-24 UNC
M5
No. 10-24 UNC
"
E
"
mm (IN.)
10 (.39)
12 (.47)
10 (.39)
12 (.47)
10 (.39)
12 (.47)
1/8 BSP.F
Model Numbers
DSHG-01-

-
-13
DSHG-01-

-
-1390
"C"
Thd.
G 1/2
1/2 NPT
Rc 1/4
1/4 NPT
"D"
Thd.
A
T
P
B
SOL b
SOL a
SOL b
SOL a
12.7(.50)
30.2
(1.19)
40.5
(1.59)
14.2
(.56)
0.75
(.03)
15.5
(.61)
8.5
(.33)
7.5
(.30)
7 (.28) Dia.
4 Places
"
D
" Thd. "
E
" Deep
4 Places
21.5
(.85)
5.2
(.20)
25.8
(1.02)
31
(1.22)
31.75
(1.25)
48
(1.89)
63
(2.48)
71
(2.80)
85
(3.35)
7
(.28)
7 (.28) Dia. Through
11 (.43) Dia. Spotface
2 Places
15
(.59)
16
(.63)
32
(1.26)
11
(.43)
24
(.94)
37
(1.46)
12.5
(.49)
35.5
(1.40)
58.5
(2.30)
"
C
" Thd.
4 Places
40.5
(1.59)
Space Needed to Remove
Solenoid-Each End
AC :
DC,R :
45.5 (1.79)
55 (2.17)
Cylinder Port
"B"
Pressure Port
"P"
Cylinder Port
"A"
AC :
DC,R :
191.4 (7.54)
210 (8.27)
AC :
DC,R :
74.2 (2.92)
83.5 (3.29)
Tank Port
"T"
Solenoid Indicator Light
31
(1.22)
32.5
(1.28)
130.3
(5.13)
Manual Actuator
6(.24)
Dia.
48
(1.89)
112
(4.41)
78
(3.07)
65
(2.56)
43.5
(1.71)
125
(4.92)
AC :
DC,R :
158.2 (6.23)
167.5 (6.59)
Electrical Conduit Connection
"C"
Thd. (Both Ends)
90
(3.54)
0.5
(.02)
0.75
(.03)
Double Solenoid
Models Only
Mounting Surface
(O-Rings Furnished)
Pilot Drain Port
"Y"
"D"
Thd.
Pilot Pressure Port
"X"
"D"
Thd.
60
(2.36)
105
(4.13)
118
(4.65)
152
(5.98)
170.3
(6.70)
No.18
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01
Sub- plates
Terminal Box type: DSHG-01-

-
-13/1390
Internal Pilot - Internal Drain
External Pilot - External Drain
External Pilot - Internal Drain
Internal Pilot - External Drain
For other dimensions, refer to "Internal Pilot Internal
Drain".
DIMENSIONS IN
MILLIMETRES (INCHES)
DSGM-01
-30/3080/3090
DIRECTIONAL
CONTROLS
E
Mounting surface: ISO 4401-AB-03-4-A
Installation Drawing
Model Numbers
DSHG-01-

-
-N
-13
DSHG-01-

-
-N
-1380
DSHG-01-

-
-N
-1390
"J"
Thd.
Rc 1/4
1/4 BSP.F
1/4 NPT
Model Numbers
Dimensions mm (Inches)
CDEFHJ L
130 (5.12)
141 (5.55)
144 (5.67)
53 (2.09)
64 (2.52)
57.2 (2.25)
27.5 (1.08)
27.5 (1.08)
34 (1.34)
39 (1.54)
39 (1.54)
53 (2.09)
170 (6.69)
181 (7.13)
184 (7.24)
74.2 (2.92)
83.5 (3.29)
191.4 (7.54) 158.2 (6.23)
210 (8.27) 167.5 (6.59)
DSHG-01-

-
-A
-N/N1
DSHG-01-

-
-D
-N/N1
DSHG-01-

-
-R
-N
K
SOL a
SOL b
SOL a
SOL b
Pilot Pressure Port
"X"
"J"
Thd.
Pilot Drain Port
"Y"
"J"
Thd.
60
(2.36)
118
(4.65)
L
D
105
(4.13)
D
65
(2.56)
C
48
(1.89)
E
H
F
27
(1.06)
(2.76)
70
78
(3.07)
43.5
(1.71)
125
(4.92)
K
J
Cable Departure
Cable Applicable:
Outside Dia.

8-10mm(.31-.39 IN.)
Conductor Area

Not Exceeding
2
1.5mm (.002 Sq. IN.)
The position of the Plug-in connector can be changed as
illustrated below by loosening the lock nut. After
completion of the change, be sure to tighten the lock nut
with the torque as specified below.
Lock Nut
Tightening Torque:
10.3
-
11.3
Nm (
91-100
IN.lbs.)
No.19
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01
External Pilot-External Drain
External Pilot-Internal Drain
Internal Pilot-External Drain
Plug-in Connector Type: DSHG-01-

-
- -13/1380/1390
Internal Pilot-Internal Drain
N
N1
For other dimensions, refer to "Terminal Box Type".
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
Mounting surface: ISO 4401-AC-05-4-A
(The pilot and drain ports in accordance
with the ISO original draft)
Installation Drawing
Model Numbers
DSHG-03-

-
-13
DSHG-03-

-
-1390
"C"
Thd.
G 1/2
1/2 NPT
Model Numbers
Dimensions mm (Inches)
CDEFHJ
53 (2.09)
64 (2.52)
57.2 (2.25)
175 (6.89)
186 (7.32)
189 (7.44)
27.5 (1.08)
27.5 (1.08)
34 (1.34)
179.7 (7.07)
189 (7.44)
191.4 (7.54) 47.2 (1.86)
210 (8.27) 56.5 (2.22)
DSHG-03-

-
-A
-N/N1
DSHG-03-

-
-D
-N/N1
DSHG-03-

-
-R
-N
K
39 (1.54)
39 (1.54)
53 (2.09)
SOL a
SOL b
SOL a
SOL b
Space Needed to Remove
Solenoid-Each End
Manual Actuator
6(.24)
Dia.
Electrical Conduit Connection
"C"
Thd. (Both Ends)
Mounting Surface
(O-Rings Furnished)
Double Solenoid
Models Only
70
(2.76)
58
(2.28)
170
(6.69)
90
(3.54)
0.5
(.02)
1
(.04) (1.73)
44
AC :
DC,R :
179.7 (7.07)
189 (7.44)
27
(1.06)
110
(4.33)
157
(6.18)
175.3
(6.90)
Tank Port
"T"
Solenoid
Indicator Light
Cylinder Port
"B"
Pressure Port
"P"
Cylinder Port
"A"
7(.28)
Dia. Through,
11(.43)
Dia. Spotface 4 Places
54
(2.13)
Pilot Drain Port
"Y"
(For External Drain Models Only)
Pilot Pressure Port
"X"
(For External Pilot Models Only)
AC :
DC,R :
67.7 (2.67)
77 (3.03)
AC :
DC,R :
45.5 (1.79)
55 (2.17)
AC :
DC,R :
191.4 (7.54)
210 (8.27)
70
(2.76)
F
E
D
27
(1.06)
110
(4.33)
58
(2.28)
170
(6.69)
H
J
K
C
97
(3.82)
Cable Departure
Cable Applicable:
Outside Dia.

8-10mm(.31-.39 IN.)
Conductor Area

Not Exceeding
2
1.5mm (.002 Sq. IN.)
46
(1.81)
No.20
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-03
Terminal Box Type: DSHG-03-

-
-13/1390
Position of cable departure can be changed. For
details, refer to DSHG-01 valve on page 19.
Of the two of tank port "T", the tank port
in the left side is normally used in our
standard sub-plate, though, either side of
the tank port "T" can be used without
problem.
For other dimensions, refer to "Terminal Box Type".
Plug-in Connector Type: DSHG-03-

-
- -13/1390
N
N1
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
E
Mounting surface:
ISO 4401-AD-07-4-A
Installation Drawing
Model Numbers "
C
" Thd.
(S-)DSHG-04-

-
-51
(S-)DSHG-04-

-
-5190
G 1/2
1/2 NPT
Model Numbers
(S-)DSHG-04-

-A
-N/N1
(S-)DSHG-04-

-D
-N/N1
(S-)DSHG-04-

-R
-N
Dimensions mm (Inches)
CD E F J KH
39
39
53
(1.54)
(1.54)
(2.09)
53
64
57.2
(2.09)
(2.52)
(2.25)
181
192
195
(7.13)
(7.56)
(7.68)
27.5
27.5
34
(1.08)
(1.08)
(1.34)
191.4 (7.54)
210 (8.27)
47.2 (1.86)
56.5 (2.22)
44.1 (1.74)
53.4 (2.10)
SOL a
SOL b
LL'
SOL a
SOL b
A P B
34
(1.34)
AC :
DC,R :
191.4
210
90
(3.54)
0.5
(.02)
(7.54)
(8.27)
AC :
DC,R :
50.7
60
(2.00)
(2.36)
AC :
DC,R :
45.5
55
(1.79)
(2.17)
AC :
DC,R :
44.1
53.4
(1.74)
(2.10)
101.6
(4.00)
50.4
(1.98)
204(8.03)
Tank Port "
T
"
11(.43)
Dia. Through
17.5(.69)
Dia. Spotface
4 Places
Pressure Port "
P
"
Pilot Pressure Port "
X
"
(For External Pilot Models Only)
50
(1.97)
34.9
(1.37)
69.8
(2.75)
1.5
(.06)
72.9
(2.87)
91
(3.58)
Pilot Drain Port "
Y
"
(For External Drain Models Only)
Cylinder Port "
B
"
Solenoid Indicator Light
Cylinder Port "
A
"
7(.28)
Dia. Through
11(.43)
Dia. Spotface
2 Places
116
(4.57)
163
(6.42)
181.3
(7.14)
Space Needed to Remove
Solenoid-Each End
Double Solenoid
Models Only
34
(1.34)
4
(.16)
35
(1.38)
Manual Actuator
6(.24)
Dia.
Nut
22(.87)
Hex.
3(.12)
Dia. Two Locating Pins
Electrical Conduit Connection
"
C
" Thd. (Both Ends)
48
(1.89)
Mounting Surface
(O-Rings Furnished)
Cable Departure
Cable Applicable:
Outside Dia. 8-10 mm(.31 - .39 IN.)
2
Conductor Area Not Exceeding 1.5 mm (.002 Sq. IN.)
......
...
H
0.5
(.02)
J
C
D
K
116
(4.57)
E
F
34
(1.34)
35
(1.38)
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-04 / S-DSHG-04
No.21
Terminal Box Type: (S-)DSHG-04-

-
-51/5190
Plug-in Connector Type: (S-)DSHG-04-

-
- -51/5190
N
N1
Position of cable
departure can be
changed. For details,
refer to DSHG-01
valve on page 19.
For other dimensions, refer to "Terminal Box Type".
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
Mounting surface:
ISO 4401-AE-08-4-A
Installation Drawing
Model Numbers "
C
" Thd.
(S-)DSHG-06-

-
-52
(S-)DSHG-06-

-
-5290
G 1/2
1/2 NPT
Model Numbers
(S-)DSHG-06-

-A
-N/N1
(S-)DSHG-06-

-D
-N/N1
(S-)DSHG-06-

-R
-N
Dimensions mm (Inches)
CD E F J KH
39
39
53
(1.54)
(1.54)
(2.09)
53
64
57.2
(2.09)
(2.52)
(2.25)
202
213
216
(7.95)
(8.39)
(8.50)
27.5
27.5
34
(1.08)
(1.08)
(1.34)
191.4 (7.54)
210 (8.27)
47.2 (1.86)
56.5 (2.22)
42.7 (1.68)
52 (2.05)
X
A
B
Y
P
T
SOL a
SOL b
APB
LL'
SOL a
SOL b
A P B
53.2
(2.09)
AC :
DC,R :
191.4
210
90
(3.54)
0.5
(.02)
(7.54)
(8.27)
AC :
DC,R :
50.7
60
(2.00)
(2.36)
AC :
DC,R :
45.5
55
(1.79)
(2.17)
AC :
DC,R :
45.5
55
(1.79)
(2.17)
130.2
(5.13)
255(10.04)
Tank Port "
T
"
13.5(.53)
Dia. Through
20(.79)
Dia. Spotface
6 Places
Pressure Port "
P
"
Pilot Pressure Port "
X
"
(For External Pilot Models Only)
77
(3.03)
46.1
(1.81)
92.1
(3.63)
13
(.51)
118
(4.65)
Pilot Drain Port "
Y
"
(For External Drain Models Only)
Cylinder Port "
B
"
Solenoid Indicator Light
Cylinder Port "
A
"
Space Needed to Remove
Solenoid-Each End
6
(.24)
Manual Actuator
6(.24)
Dia.
Nut
22(.87)
Hex.
6(.24)
Dia. Two Locating Pins
Electrical Conduit Connection
"
C
" Thd. (Both Ends)
48
(1.89)
Mounting Surface
(O-Rings Furnished)
Cable Departure
Cable Applicable:
Outside Dia. 8-10 mm(.31 - .39 IN.)
2
Conductor Area Not Exceeding 1.5 mm (.002 Sq. IN.)
......
...
H
97
(3.82)
J
C
D
K
137
(5.39)
E
F
41
(1.61)
50.5
(1.99)
156
(6.14)
137
(5.39)
184
(7.24)
202.3
(7.96)
41
(1.61)
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-06 / S-DSHG-06
Terminal Box Type: (S-)DSHG-06-

-
-52/5290
Plug-in Connector Type: (S-)DSHG-06-

-
- -52/5290
N
N1
For other dimensions, refer to "Terminal Box Type".
Position of cable departure can be changed. For details, refer to DSHG-01 valve on page 19.
DIMENSIONS IN
MILLIMETRES (INCHES)
No.22
DIRECTIONAL
CONTROLS
E
Mounting surface:
ISO 4401-AF-10-4-A
Installation Drawing
Model Numbers "
C
" Thd.
(S-)DSHG-10-

-
-42
(S-)DSHG-10-

-
-4290
G 1/2
1/2 NPT
Model Numbers
(S-)DSHG-10-

-A
-N/N1
(S-)DSHG-10-

-D
-N/N1
(S-)DSHG-10-

-R
-N
Dimensions mm (Inches)
CD E F J KH
39
39
53
(1.54)
(1.54)
(2.09)
53
64
57.2
(2.09)
(2.52)
(2.25)
265
276
279
(10.43)
(10.87)
(10.98)
27.5
27.5
34
(1.08)
(1.08)
(1.34)
191.4 (7.54)
210 (8.27)
47.2 (1.86)
56.5 (2.22)
19.7 (.78)
29 (1.14)
SOL a
SOL b
APB
L
L'
198
(7.80)
X
X
SOL a
SOL b
A P B
76.2
(3.00)
AC :
DC,R :
191.4
210
90
(3.54)
(7.54)
(8.27)
AC :
DC,R :
50.7
60
(2.00)
(2.36)
AC :
DC,R :
45.5
55
(1.79)
(2.17)
AC :
DC,R :
19.7
29
(.78)
(1.14)
190.5
(7.50)
384(15.12)
Tank Port "
T
"
Pressure Port "
P
"
Pilot Pressure Port "
X
"
(For External Pilot Models Only)
78
(3.07)
43(1.69)
158.8
(6.25)
19.6
(.77)
79.4
(3.13)
Cylinder Port "
B
"
Solenoid Indicator Light
Cylinder Port "
A
"
200
(7.87)
247
(9.72)
265.3
(10.44)
Space Needed to Remove
Solenoid-Each End
Two Eye Bolts M8
44.5
(1.75)
6
(.24)
46
(1.81)
Manual Actuator
6(.24)
Dia.
Nut
22(.87)
Hex.
6(.24)
Dia. Two Locating Pins
Electrical Conduit Connection
"
C
" Thd. (Both Ends)
48
(1.89)
Mounting Surface
(O-Rings Furnished)
Cable Departure
Cable Applicable:
Outside Dia. 8-10 mm(.31 - .39 IN.)
2
Conductor Area Not Exceeding 1.5 mm (.002 Sq. IN.)
......
...
H
97
(3.82)
J
C
D
K
200
(7.87)
F
77.5
(3.05)
21.5(.85)
Dia. Through
32(1.26)
Dia. Spotface
6 Places
Pilot Drain Port "
Y
"
(For External Drain Models Only)
114.3
(4.50)
21.8
(.86)
233.8(9.20)
0.5
(.02)
E
45
(1.77)
46
(1.81)
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-10 / S-DSHG-10
No.23
Terminal Box Type: (S-)DSHG-10-

-
-42/4290
Plug-in Connector Type: (S-)DSHG-10-

-
- -42/4290
N
N1
Position of cable
departure can be
changed. For details,
refer to DSHG-01
valve on page 19.
For other dimensions, refer to "Terminal Box Type".
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
1.
2.
3.
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
Options
Model Numbers
CDEFH
AC SOL DC SOL R SOL
J
Dimensions mm (Inches)
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)
(S-)
DSHG-03-

-C1
DSHG-03-

-C2
DSHG-03-

-C1C2
DSHG-04-

-C1
DSHG-04-

-C2
DSHG-04-

-C1C2
DSHG-06-

-C1
DSHG-06-

-C2
DSHG-06-

-C1C2
DSHG-10-

-C1
DSHG-10-

-C2
DSHG-10-

-C1C2
200.3 (7.89)
225.3 (8.87)
206.3 (8.12)
231.3 (9.11)
227.3 (8.95)
252.3 (9.93)
290.3 (11.43)
315.3 (12.41)
182 (7.17)
207 (8.15)
188 (7.40)
213 (8.39)
209 (8.23)
234 (9.21)
272 (10.71)
297 (11.69)
135 (5.31)
160 (6.30)
141 (5.55)
166 (6.54)
162 (6.38)
187 (7.36)
225 (8.86)
250 (9.84)
100 (3.94)
125 (4.92)
106 (4.17)
131 (5.16)
127 (5.00)
152 (5.98)
190 (7.48)
215 (8.46)
100 (3.94)
100 (3.94)
106 (4.17)
106 (4.17)
127 (5.00)
127 (5.00)
190 (7.48)
190 (7.48)
200 (7.87)
225 (8.86)
206 (8.11)
231 (9.09)
227 (8.94)
252 (9.92)
390 (15.35)
415 (16.34)
211 (8.31)
236 (9.29)
217 (8.54)
242 (9.53)
238 (9.37)
263 (10.35)
401 (15.79)
426 (16.77)
214 (8.43)
239 (9.41)
220 (8.66)
245 (9.65)
241 (9.49)
266 (10.47)
404 (15.91)
429 (16.89)
APB
SOL a
SOL b
SOL a SOL b
Fully Extended
59
(2.32)
Fully
Extended
59 (2.32)
37.5
(1.48)
H
F
E
D
C
SOL a
SOL b
SOL a
SOL b
E
D
H
F
C
E
D
F
H
C
Fully Extended
59 (2.32)
SOL a SOL b
E
J
H
F
Fully
Extended
59 (2.32)
37.5
(1.48)
E
J
H
F
Fully Extended
59
(2.32)
E
Fully Extended
59 (2.32)
F
H
J
SOL a SOL b
PAB
No.24
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-03, 04, 06, 10 / S-DSHG-04, 06, 10
Models with Pilot Choke Valve
Terminal Box Type
DSHG-03-

-C1/C2/C1C2
(S-)DSHG-04-

-C1/C2/C1C2
06
10
(S-)DSHG- -

-C1/C2/C1C2
Plug-in Connector Type
DSHG-03-

N
N1
-C1/C2/C1C2-
(S-)DSHG-04-

N
N1
-C1/C2/C1C2-
06
10
(S-)DSHG- -

N
N1
-C1/C2/C1C2-
"C1" Choke Adj. Screw 6 (.24) Hex.
"C2" Choke Adj. Screw 6 (.24) Hex.
Lock Nut 12 (.47) Hex.
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
E
Options
Model Numbers
(S-)DSHG-06-

-R2
(S-)DSHG-10-

-R2
CDE
376 (14.80)
558 (21.97)
111 (4.37)
164.5 (6.48)
40 (1.57)
65 (2.56)
Model Numbers
(S-)DSHG-06-3H
C
306.5 (12.07)
456 (17.95)
D
102 (4.02)
149.5 (5.89)
Model Numbers
C
323 (12.72)
479 (18.86)
D
84 (3.31)
125 (4.92)
(S-)DSHG-06-

-P2
(S-)DSHG-10-

-P2
SOL a
SOL b
SOL a
SOL b
SOL a
SOL b
A P B
SOL a
SOL b
A P B
SOL a
SOL b
A P B
Stroke Adj. Screw (Port
"B"
End)
17 (.67)
Hex.
E
D
Fully Extended
C
Fully Extended
Fully Extended
93 (3.66)
Stroke Adj. Screw (Port
"A"
End)
17 (.67)
Hex.
Lock Nut
24(.94)
Hex.
Fully Extended
289 (11.38)
33
(1.30)
Stroke Adj. Screw (Port
"A"
End)
13 (.51)
Hex.
Stroke Adj. Screw (Port
"B"
End)
13 (.51)
Hex.
Lock Nut
17(.67)
Hex.
Fully Extended
99 (3.90)
Stroke Adj. Screw (Port
"A"
End)
13 (.51)
Hex.
Stroke Adj. Screw (Port
"B"
End)
13 (.51)
Hex.
35
(1.38)
Lock Nut
17(.67)
Hex.
Fully Extended
252 (9.92)
D
C
C
D
No.25
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-03, 04, 06, 10 / S-DSHG-04, 06, 10
Models with Stroke Adjustment
DSHG-03-

-R
(S-)DSHG-04-

-R
06
10
(S-)DSHG- -

-R
Pressure Centred Models Models with Pilot Piston
06
10
(S-)DSHG- -3H
06
10
(S-)DSHG- -

-P
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
Installation Drawing
Sub-plate
Model Numbers
DHGM-03Y-10
DHGM-03Y-1080
DHGM-03Y-1090
"
C
" Thd. "
D
" Thd.
Rc 3/4
3/4 BSP.F
3/4 NPT
"
E
" Thd.
13(.51)
15(.59)
Rc 1/4
1/4 BSP.F
1/4 NPT
M6
1/4-20 UNC
F
mm (in.)
Sub-plate
Model Numbers
DHGM-04-20
DHGM-04X-20
"
C
" Thd.
Rc 1/2
Rc 3/4
"
E
" Thd.
M10
3/8-16 UNC
1/2 BSP.F
3/4 BSP.F
1/2 NPT
3/4 NPT
"
D
" Thd.
Rc 1/4
1/4 BSP.F
1/4 NPT
"
F
" Thd.
M6
1/4-20 UNC
DHGM-04-2080
DHGM-04X-2080
DHGM-04-2090
DHGM-04X-2090
Valve Types
Spring Centred
No-spring
Solenoid Controlled Pilot
Operated Directional Valves
Pilot Operated
Directional
Valves
Manually Operated Directional Valves
Spring Offset
Pilot Pressure Port "
X
"Port "
Y
"
Used only on external pilot type
valves.
To be plugged on internal pilot
type valves.
Used
Not used (plug is not required)
Used as drain port only on external
drain type valves.
To be plugged on internal drain
type valves.
Used as drain port
Used as pilot drain port
Used as pilot pressure port
120
(4.72)
90
(3.54)
15
(.59)
110
(4.33)
22(.87)
"
D
" Thd.
Used only on external
pilot type valves.
To be plugged on internal
pilot type valves.
"
E
" Thd. "
F
" Deep
4 Places
25
(.98)
19
(.75)
90
(3.54)
46
(1.81)
10
(.39)
32.5(1.28)
21.5(.85)
6.4(.25)
6.2(.24)
Dia.
6.2(.24)
Dia.
19
(.75)
92
(3.62)
11
(.43)
12
(.47)
70
(2.76)
11(.43)
Dia.
4 Places
18
(.71)
62
(2.44)
54
(2.13)
37.3(1.47)
27(1.06)
16.7(.66)
8(.31)
3.2
(.13)
"
C
" Thd.
4 Places
P
T
A
B
19
(.75)
25(.98)
42(1.65)
43(1.69)
50
(1.97)
10
(.39)
45
(1.77)
80
(3.15)
16(.63)
47
(1.85)
76
(2.99)
P
T
A
B
X
Y
190
(7.48)
166
(6.54)
101.6
(4.00)
76.7
(3.02)
12(.47)
32.2(1.27)
50
(1.97)
34(1.34)
18.3(.72)
11(.43)
Dia. Through
17.5(.69)
Dia. Spotface
4 Places
3.6(.14)
Dia.
5(.20)
Deep
2 Places
14.2
(.56)
65.8
(2.59)
88.1
(3.47)
130
(5.12)
"
E
" Thd.
17(.67)
Deep
4 Places
6(.24)
Dia. 2 Places
17.5(.69)
Dia.
4 Places
"
F
" Thd.
12(.47)
Deep
2 Places
120
(4.72)
96
(3.78)
71.4
(2.81)
12
(.47)
13.1
(.52)
69.8
(2.75)
55.6
(2.19)
14.2
(.56)
1.6(.06)
16
(.63)
10.1
(.40)
57.1
(2.25)
90
(3.54)
36
(1.42)
20
(.79)
19
(.75)
P
T
A
B
X
Y
"
D
" Thd.
2 Places
125
(4.92)
90
(3.54)
46
(1.81)
65
(2.56)
29
(1.14)
58
(2.28)
102
(4.02)
137.5
(5.41)
76
(2.99)
21.5(.85)
33(1.30)
"
C
" Thd.
4 Places
"
D
" Thd.
Used only on external
drain type valves.
To be plugged on internal
drain type valves.
No.26
DHGM-03Y-10/1080/1090
DHGM- -20/2080/2090
04
04X
Sub-plate for
Solenoid Controlled Pilot Operated
Directional Valves
DIMENSIONS IN
MILLIMETRES (INCHES)
E
DIRECTIONAL
CONTROLS
Installation Drawing
F
mm (in.)
Sub-plate
Model Numbers
"
C
" Thd. "
E
" Thd.
M12
1/2-13 UNC
Rc 3/4
Rc 1
3/4 NPT
1 NPT
"
D
" Thd.
Rc 1/4
1/4 NPT
24 (.94)
26 (1.02)
DHGM-06-50
DHGM-06X-50
DHGM-06-5090
DHGM-06X-5090
Sub-plate
Model Numbers
"
C
" Thd.
3/4 BSP.F
1 BSP.F
DHGM-06-5080
DHGM-06X-5080
Dimensions mm (Inches)
DEFHJKLN
151.2 (5.95)
155.2 (6.11)
137.7 (5.42)
148 (5.83)
102 (4.02)
106 (4.17)
54.4 (2.14)
50 (1.97)
30.6 (1.20)
25 (.98)
125.8 (4.95)
130 (5.12)
78.2 (3.08)
74 (2.91)
42.5 (1.67)
32 (1.26)
204
(8.03)
12
(.47)
"
E
" Thd. "
F
" Deep
6 Places
116
(4.57)
17.5(.69)
53.2
(2.09)
29.4(1.16)
PT
A
B
Y
X
V
7(.28)
Dia.
8(.31)
Deep
2 Places
11(.43)
Dia. Through
17.5(.69)
Dia. Spotface
4 Places
23(.91)
Dia.
"
C
" Thd. (From Rear)
4 Places
11(.43)
Dia.
"
D
" Thd. (From Rear)
4 Places
180
(7.09)
25
(.98)
130.2
(5.13)
112.7
(4.44)
94.5
(3.72)
77
(3.03)
5.6(.22)
19.1(.75)
92.1
(3.63)
74.6
(2.94)
12
(.47)
46.1
(1.81)
73.1
(2.88)
96.9
(3.81)
17.5
(.69)
29.5
(1.16)
100.8
(3.97)
126.2
(4.97)
12.5
(.49)
156
(6.14)
50
(1.97)
34(1.34)
35(1.38)
P
T
AB
Y
X
V
W
204
(8.03)
180
(7.09)
12
(.47)
25
(.98)
130.2
(5.13)
M12
Thd.
24(.94)
Deep
6 Places
11(.43)
Dia.
4 Places
24.5(.96)
Dia.
4 Places
12.5
(.49)
156
(6.14)
92.1
(3.63)
110
(4.33)
134
(5.28)
8.9
(.35)
12
(.47)
11.9
(.47)
116
(4.57)
50
(1.97)
35
(1.38)
P
T
AB
Y
W
D
E
F
H
J
N
L
K
73.1
(2.88)
17.5
(.69)
19.1
(.75)
74.6
(2.94)
46.1
(1.81)
1/4 BSP.F Thd.
4 Places
"
C
" Thd.
4 Places
X
V
DHGM- -50/5090
06
06X
No.27
DHGM- -5080
06
06X
For other dimensions, refer to "DHGM-06
-50/5090" above.
Sub-plate for
Solenoid Controlled Pilot Operated
Directional Valves
For Uses of Port "X", "Y", "V", "W", refer to DHGM-10
on the following page.
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
Installation Drawing
Sub-plate
Model Numbers
"C"
Thd.
"D"
Thd.
"E"
Thd.
FH J K
Dimensions mm (Inches)
DHGM-10-40
DHGM-10-4080
DHGM-10-4090
Rc 1-1/4
1-1/4 BSP.F
1-1/4 NPT
Rc 3/8
3/8 BSP.F
3/8 NPT
M20
M20
3/4-10 UNC
152 (5.98) 79 (3.11) 185.5 (7.30) 120.5 (4.74)
DHGM-10X-40
DHGM-10X-4080
DHGM-10X-4090
Rc 1-1/2
1-1/2 BSP.F
1-1/2 NPT
Rc 3/8
3/8 BSP.F
3/8 NPT
M20
M20
3/4-10 UNC
156 (6.14) 74 (2.91) 194.5 (7.66) 112.5 (4.43)
Spring Centred, No-spring,
Spring Offset
Pressure Centred
With Pilot Piston, Both Ends
With Pilot Piston,
Port "A" End
With Pilot Piston,
Port "B" End
Solenoid
Controlled
Pilot
Operated
Directional
Valves
Used only on
external pilot type
valves.
To be plugged on
internal pilot type
valves.
Used as drain port only
on external drain type
valves.
To be plugged on
internal drain type
valves.
Not used (plug is not required)
Used Not used
Used Used
Used
Not used
(plug is required)
Not used
(plug is required)
Used
Spring Centred, No-spring
Spring Offset
Pressure Centred
With Pilot Piston, Both Ends
With Pilot Piston,
Port "B" End
With Pilot
Piston
Port "A"
End
Spring Centred
No-spring
Spring Offset
Manually Operated Directional Valves
Pilot
Operated
Directional
Valves
Used
Used as pilot pres. port
Used as pilot drain port
Used as pilot pres. port
Used as pilot pres. port
Used as pilot drain port
Not used
(plug is not required)
Not used
(plug is not required)
Not used (plug is not required)
Used
Used
Not used
(pllug is required)
Not used
Used
Used
Not used
(plug is required)
Not used (plug is
not required)
Used
Used
Valve Types Pilot Pres. Port "
X
"Port "
Y
" Drain Port "
V
" Drain Port "
W
"
Note: Uses of port "X", "Y", "V", and "W"
F
H
K
J
W
Y
P
T
V
A
B
X
Y
B
A
PT
V
X
W
41.3(1.63)
76.2(3.00)
114.3
(4.50)
147.6
(5.81)
168.3
(6.63)
190.5
(7.50)
266.5
(10.49)
38(1.50)
20(.79)
306.5
(12.07)
28.6
(1.13)
79.4
(3.13)
123.8
(4.87)
158.8
(6.25)
199
(7.83)
20.1
(.79)
82.5
(3.25)
21.8
(.86)
234
(9.21)
35
(1.38)
114.3
(4.50)
7 (.28) Dia. 8 (.31) Deep
2 Places
"E"
Thd. 34 (1.34) Deep
6 Places
11 (.43) Dia.
4 Places
17.5 (.69) Dia. Through
26 (1.02) Dia. Spotface
4 Places
36 (1.42) Dia.
4 Places
60
(2.36)
43(1.69)
44(1.73)
55
(2.17)
213
(8.39)
"C"
Thd.
4 Places
"D"
Thd.
4 Places
No.28
Sub-plate for
Solenoid Controlled Pilot Operated
Directional Valves
10
10X
DHGM- -40/4080/4090
As the thread is provided on the body, plug either port on the sub-plate or port on the body.
DIMENSIONS IN
MILLIMETRES (INCHES)
E
DIRECTIONAL
CONTROLS
Spare Parts List
Item Name
Part Numbers Qty.
DSHG-01
Part Numbers Qty.
DSHG-03
7
8
9
10
O-Ring
O-Ring
O-Ring
O-Ring
JASO-1018-1A
SO-NB-P9
SO-NB-P5
2
8(4)
2
SO-NB-P28
SO-NB-A104
SO-NB-P9
2
5
6
SO-NB-P9 2
SOL b SOL a
12
161714
15
12
2 5 4 10 11 8 3 1 7 6 13
13
18
8
Pipe Plug
Removed for External Drain Models
Pipe Plug
Removed for Internal Pilot Models
Pipe Plug
Removed for Internal Drain Models
Pipe Plug
Removed for External
Pilot Models
SOL a
SOL b
X
Y
XY
14 17 16
15
13
13
2 5 4 9 1 3 8 10 7 6
12
Pipe Plug
Removed for Internal
Pilot Models
Pipe Plug
Removed for Internal
Drain Models
No.29
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01, 03
DSHG-01-

-
-13/1380/1390
Note: Piece parts marked are not available
for internal pilot-internal drain type
DSHG-03-

-
-13/1390
Section Y-Y
Section X-X
List of Seals Pilot Valves
See page 31 for the pilot valve model numbers to be
used.
Quantities in the ( ) are applicable to internal pilot-internal drain.
Note: When ordering the o-rings, please specify the seal kit number listed
in page 31. In addition to the above o-rings, o-rings for pilot valve
is included in the seal kit.
For the detail of the pilot valve o-rings, see the catalogue No. Pub.
EC-0402.
CAUTION
When making replacement of seals or pilot valves,
please do it carefully after reading through the relevant
instructions in the Operator's Manual.
DIRECTIONAL
CONTROLS
Spare Parts List
Item Name
(S-)DSHG-04
SO-NB-P9
SO-NB-P22
SO-NB-P34
SO-NB-P9
(S-)DSHG-06
SO-NB-P14
SO-NB-P30
SO-NB-P40
SO-NB-P10
(S-)DSHG-10
SO-NB-P20
SO-NB-P42
SO-NB-P65
SO-NB-P14
Qty.
Part Numbers
2
4
2
2
O-Ring
8
9
10
18
14
15
16 17
SOL a
SOL b
X
Y
X
Y
18
10
5
4 1 3 9
13
8 2 7
12
11
11
Pipe Plug
Removed for Internal
Drain Models
Pipe Plug
Removed for Internal
Pilot Models
SOL a SOL b
X
Y
X
Y
16 14 17
15
21 21
18 2 10 5 3 1 9 13 8 4 7
11
11
12
12
Pipe Plug
Removed for Internal
Pilot Models
Pipe Plug
Removed for Internal
Drain Models
11
Pipe Plug
Removed for External
Drain Models
21
No.30
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-04,06,10 / S-DSHG-04,06,10
(S-)DSHG-04-

-
-51/5190
Section Y-Y Section X-X
(S-)DSHG-06-

-
-52/5290
(S-)DSHG-10-

-
-42/4290
Section Y-Y
Section X-X
List of Seals Pilot Valves
See page 31 for the pilot valve model numbers to be
used.
Note: When ordering the o-rings, please specify the seal kit number listed in page
31. In addition to the above o-rings, o-rings for pilot valve is included in the
seal kit.
For the detail of the pilot valve o-rings, see the catalogue No. Pub. EC-0402.
Note: Item orifice marked is applicable to pressure centred models
(3H
) with pilot pressure more than 10 MPa (1450 PSI).
CAUTION
When making replacement of seals or pilot valves,
please do it carefully after reading through the relevant
instructions in the Operator's Manual.
E
DIRECTIONAL
CONTROLS
List of Pilot Valves & Seal Kits
Valve Model Numbers Pilot Valve Model Numbers Seal Kit Numbers
DSHG-03-3C
- - -13
DSHG-03-3C
- - -1390
DSHG-01-3C
- - -13
DSHG-01-3C
- -N-1380
DSHG-01-3C
- - -1390
DSHG-01-2B
- - -13
DSHG-01-2B
- -N-1380
DSHG-01-2B
- - -1390
DSHG-03-2B
- - -13
DSHG-03-2B
- - -1390
DSHG-03-2N
- - -13
DSHG-03-2N
- - -1390
(S-)DSHG-04-3C
- - -51
(S-)DSHG-04-3C
- - -5190
(S-)DSHG-04-2B
- - -51
(S-)DSHG-04-2B
- - -5190
(S-)DSHG-04-2N
- - -51
(S-)DSHG-04-2N
- - -5190
(S-)DSHG-06-3C
- - -52
(S-)DSHG-06-3C
- - -5290
(S-)DSHG-06-2B
- - -52
(S-)DSHG-06-2B
- - -5290
(S-)DSHG-06-2N
- - -52
(S-)DSHG-06-2N
- - -5290
(S-)DSHG-10-3C
- - -42
(S-)DSHG-10-3C
- - -4290
(S-)DSHG-10-2B
- - -42
(S-)DSHG-10-2B
- - -4290
(S-)DSHG-10-2N
- - -42
(S-)DSHG-10-2N
- - -4290
DSG-01-3C4- - -60
DSG-01-3C4- -N-60
DSG-01-3C4- - -6090
DSG-01-2B2- - -60-L
DSG-01-2B2- -N-60-L
DSG-01-2B2- - -6090-L
DSG-01-3C4- - -60
DSG-01-3C4- - -6090
DSG-01-2B2- - -60
DSG-01-2B2- - -6090
DSG-01-2D2- - -60
DSG-01-2D2- - -6090
DSG-01-3C4- - -60
DSG-01-3C4- - -6090
DSG-01-2B2- - -60
DSG-01-2B2- - -6090
DSG-01-2D2- - -60
DSG-01-2D2- - -6090
DSG-01-3C4- - -60
DSG-01-3C4- - -6090
DSG-01-2B2- - -60-L
DSG-01-2B2- - -6090-L
DSG-01-2D2- - -60
DSG-01-2D2- - -6090
DSG-01-3C4- - -60
DSG-01-3C4- - -6090
DSG-01-2B2- - -60-L
DSG-01-2B2- - -6090-L
DSG-01-2D2- - -60
DSG-01-2D2- - -6090
KS-DSHG-01- -13
(For Internal Pilot-Internal Drain)
KS-DSHG-01-ET- -13
(Except for Internal Pilot-Internal Drain)
KS-DSHG-03- -13
KS-DSHG-04- -51
KS-DSHG-06- -52
KS-DSHG-10- -42
Notes)1:
2:
Fill coil type (a symbol representing current/voltage) in section marked . Likewise, in section marked , fill a symbol
representing the type of electrical conduit connection (None: Terminal Box Type, N: Plug-in Connector Type).
For the details of the pilot valves, see the catalogue No. Pub.EC-0402.
No.31
Solenoid Controlled Pilot Operated
Directional Valves
DSHG / S-DSHG
DIRECTIONAL
CONTROLS
Interchangeability between Curent and New Design
No changes
Yes
DSG-01-

-
-50
DSG-01-

-
-60
For details, refer to the Catalogue No. Pub. EC-0402
Pilot Valve
Specifications
Interchangeability in Mtg.
Current
DSHG-01-

-
-12
DSHG-01-

-
-12
New
DSHG-01-

-
-13
DSHG-01-

-
-13
Descriptions
Model No.
130.3 (5.13)
170.3 (6.70)
C
Model No.
DSHG-01-T
DSHG-01-E/ET/None
HCBA
AC
DC
R
AC
DC
R
DSHG-01-T
E
ET
None
DSHG-01-
Model No.
191.4 (7.54)
191.4 (7.54)
210
(8.27)
210
(8.27)
50.7 (2.00)
50.7 (2.00)
60
(2.36)
60
(2.36)
76.7 (3.02)
76.7 (3.02)
86
(3.39)
86
(3.39)
130.3
(5.13)
170.3
(6.70)
HBA
AC
DC
R
DSHG-03
Model No.
191.4 (7.54)
210
(8.27)
50.7 (2.00)
60
(2.36)
67.7 (2.67)
77
(3.03)
SOL a
SOL b
SOL b
SOL a
SOL a
SOL b
SOL a
SOL b
210
(8.27)
60
(2.36)
90
(3.54)
0.5
(.02)
86
(3.29)
90
(3.54)
0.5
(.02)
210
(8.27)
60
(2.36)
90
(3.54)
0.5
(.02)
77
(3.03)
0.5
(.02)
90
(3.54)
C
C
B
A
H
B
A
H
175.3
(6.90)
175.3
(6.90)
No.32
Solenoid Controlled Pilot Operated
Directional Valves
DSHG-01 / 03
DSHG-01
In accordance with the improvement of the pilot valve (DSG-01), DSHG-01 and -03 have been model-changed (from
12-design to 13-design).
DSHG-01, 03
DSHG-03
Current New
DIMENSIONS IN
MILLIMETRES (INCHES)
DIRECTIONAL
CONTROLS
E
Interchangeability between Current and New Design
No changes
Yes
DSG-01-

-
-50
DSG-01-

-
-60
For details, refer to the Catalogue No. Pub. EC-0402.
Pilot Valve
Specifications
Interchangeability in Mtg.
Current
(S-)DSHG-04-

-
-50
Descriptions
Model No.
New
(S-)DSHG-04-

-
-51
No changes
Yes
DSG-01-

-
-50
DSG-01-

-
-60
For details, refer to the Catalogue No. Pub. EC-0402
Pilot Valve
Specifications
Interchangeability in Mtg.
Current
(S-)DSHG-06-

-
-51
(S-)DSHG-10-

-
-41
New
(S-)DSHG-06-

-
-52
(S-)DSHG-10-

-
-42
Descriptions
Model No.
202.3 (7.96)
265.3 (10.44)
C
Model No.
(S-)DSHG-06
(S-)DSHG-10
HCBA
AC
DC
R
AC
DC
R
(S-)DSHG-06
Model No.
191.4 (7.54)
191.4 (7.54)
210
(8.27)
210
(8.27)
50.7 (2.00)
50.7 (2.00)
60
(2.36)
60
(2.36)
42.7 (1.68)
19.7 (.78)
52 (2.05)
29
(1.14)
202.3
(7.96)
265.3
(10.44)
51.3 (2.02)
28.5 (1.12)
H
(S-)DSHG-10
SOL bSOL a
SOL a
SOL b
SOL a
SOL b
APB
APB
SOL a SOL b
53.4
(2.10)
210
(8.27)
(2.36)
90
(3.54)
0.5
(.02)
60
0.5
(.02)
181.3
(7.14)
181.3
(7.14)
AC :
DC,R :
191.4 (7.54)
210 (8.27)
AC :
DC,R :
50.7 (2.00)
60 (2.36)
AC :
DC,R :
44.1 (1.74)
53.4 (2.10)
210
(8.27)
(2.36)
90
(3.54)
0.5
(.02)
60
C
H
H
C
90
(3.54)
0.5
(.02)
A
B
90
(3.54)
No.33
Solenoid Controlled Pilot Operated
Directional Valves
(S)-DSHG-04 / 06 / 10
(S-) DSHG-04 has been model changed in accordance with the improvement of the pilot valve (DSG-01).
For details, see the following.
(S-)DSHG-04
(S-) DSHG-06 and -10 have been model changed in accordance with the improvement of the pilot valve (DSG-01).
For details, see below.
(S-)DSHG-06,10
Current New
Current New
DIMENSIONS IN
MILLIMETRES (INCHES)