FLOW
CONTROLS
D
Petroleum base oils
Synthetic fluids
Water containing fluids
Use fluids equivalent to ISO VG 32 or VG 46.
Use phosphate ester or polyol ester fluid. When phosphate ester fluid is used, prefix "F-" to the
model number because the special seals (fluororubber) are required to be used.
Use water-glycol fluid.
FHG
FHCG
T
P
A
O
M
B
A
O
M
B
T
P
FG
FCG
Up to 21 MPa (3050 PSI), 500 L/min (132 U.S.GPM)
No.1
FLOW CONTROL (AND CHECK) VALVES
Pub. EC-0301
-01/02/03/06/10 (1/8,1/4,3/8,3/4,1-1/4)
FG
FCG
PILOT OPERATED
FLOW CONTROL (AND CHECK) VALVES
-02/03/06/10 (1/4,3/8,3/4,1-1/4)
FHG
FHCG
Sub-plate Mounting
Flow Control and Check Valves ...... Page 2
These valves are pressure and temperature compen-
sating type valves and maintain a constant flow rate
independent of change in system pressure (load) and
temperature (viscosity of the fluid). They control flow
rate of the hydraulic circuit and eventually control
speed of the actuator precisely.
Valves with an integral check valve allow a controlled
flow and reverse free flow. Repeated resetting can be
made easily with a digital readout.
Pilot Operated Flow Control
and Check Valves ......................... Page 14
Flow control of these valves is continuously made by
a hydraulically operated pilot piston mechanism
which controls opening area of the orifice of
the valve. With the use of these valves, shockless
operation either in acceleration or deceleration can be
obtained. With the compensator for the pressure and
temperature, stable flow control can be obtained
regardless of the changes in the pressure (load) and
temperature (oil viscosity).
Hydraulic Fluids
Recommended Viscosity and Oil Temperatures
2
Viscosity ranging between 15 - 400 mm /s (77 - 1800 SSU).
Oil temperatures between -15/+70°C (5 - 158°F).
Use hydraulic fluids which satisfy the recommended viscosity and oil temperatures given above.
Control of Contamination
Due caution must be paid to maintaining control over contamination of the hydraulic fluids which may otherwise
lead to breakdowns and shorten the life of the valves. Please maintain the degree of contamination within NAS 1638-
Grade 12. Use 25
μ
m or finer line filter.
Fluid Types
Any type of hydraulic fluids listed in the table below can be used.
Note: For use with hydraulic fluids other than those listed above, please consult your Yuken representatives in advance.
FLOW
CONTROLS
Specifications / Model Number Designation / Others
Special Seals
for Phosphate
Ester Type
Fluids
(Omit if not
required)
F:
F:
Flow Control
Valves
-11
Design
Number
Design
Standards
Refer to
F- FC -01 -8
Max. Metred Flow Capacity
L/min (U.S.GPM)
Valve
Size
01
Special Seals Series Number
Model Number Designation
4
8
:
:
4 (1.06)
8 (2.1)
0.02 (.005)
{0.04 (.011)}
14 (2030)
21 (3050)
FC:
Flow Control and
Check Valves
G
Type of
Mounting
G:
Sub-plate
Mounting
02
03
06
10
30 :
30 (7.9)
125 :
125 (33)
250 :
250 (66)
500 :
500 (132)
11
30
30
30
30
-N
Pres. Compensator
Stroke Adjustment
N:
Applicable only for
Pres. Compensator
Stroke Adjustment
(Option - Omit if
not required)
FG/FCG-01
FG/FCG-02
FG/FCG-03
FG/FCG-06
FG/FCG-10
Model Numbers
MPa (PSI)
8 (2.1)
30 (7.9)
125 (33)
250 (66)
500 (132)
The figures in the brace are for pressures above 7 MPa (1020 PSI).
4
8
-01- -
-11
FG
FCG
-02-30-
-30
FG
FCG
-03-125-
-30
FG
FCG
-06-250-
-30
FG
FCG
-10-500-
-30
FG
FCG
Max.
Operating Pressure
L/min (U.S.GPM)
Max. Metred
Flow Capacity
L/min (U.S.GPM)
Min. Metred
Flow Capacity
kg (lbs.)
Approx. Mass
0.05 (.013)
0.2 (.053)
2 (.53)
4 (1.06)
1.3 (2.9)
3.8 (8.4)
7.9 (17.4)
23 (50.7)
52 (115)
M5 55 Lg.
M8 50 Lg.
M10 75 Lg.
M16 130 Lg.
M20 160 Lg.
×
×
×
×
×
4
4
4
4
4
No.10-24 UNC 2-1/4 Lg.
5/16-18 UNC 2 Lg.
3/8-16 UNC 3 Lg.
5/8-11 UNC 5 Lg.
3/4-10 UNC 6-1/2 Lg.
×
×
×
×
×
Valve Model
Numbers
Socket Head Cap Screw
Japanese Std. "JIS" &
European Design Std.
N. American Design Std.
Qty.
Graphic Symbols
FG
FCG
No.2
Flow Control (and Check) Valves
Specifications
Design Standards: None
90
Japanese Standard "JIS" and European Design Standard
N. American Design Standard
...........
...............
-01/02/03/06/10
FG
FCG
Sub-plate Mounting
Attachment
Option
Can reduce jumping at the start of the actuator.
Mounting Bolts
Pres. compensator stroke adjustment
FLOW
CONTROLS
Sub-plate / Instructions
D
2.3 (5.1)
2.3 (5.1)
3.1 (6.8)
3.9 (8.6)
3.9 (8.6)
5.7 (12.6)
5.7 (12.6)
12.5 (27.6)
16 (35.3)
16 (35.3)
Valve
Model
Numbers
-01
FG
FCG
-02
FG
FCG
-03
FG
FCG
-06
FG
FCG
-10
FG
FCG
Japanese Standard "JIS"
Sub-plate
Model No.
Thread
Size
European Design Std.
Sub-plate
Model No.
Sub-plate
Model No.
N. American Design Std.
Approx.
Mass
kg (lbs.)
FGM-01X-10
FGM-02-20
FGM-02X-20
FGM-02Y-20
FGM-03-20
FGM-03X-20
FGM-03Y-20
FGM-03Z-20
FGM-06X-20
FGM-06Y-20
FGM-06Z-20
FGM-10Y-20
Rc 1/4
Rc 1/4
Rc 3/8
Rc 1/2
Rc 3/8
Rc 1/2
Rc 3/4
Rc 1
Rc 1
Rc 1-1/4
Rc 1-1/2
1-1/2, 2
FGM-01X-1080
FGM-02-2080
FGM-02X-2080
FGM-02Y-2080
FGM-03-2080
FGM-03X-2080
FGM-03Y-2080
FGM-03Z-2080
FGM-06X-2080
FGM-06Y-2080
FGM-06Z-2080
FGM-10Y-20
1/4 BSP.F
1/4 BSP.F
3/8 BSP.F
1/2 BSP.F
3/8 BSP.F
1/2 BSP.F
3/4 BSP.F
1 BSP.F
1 BSP.F
1-1/4 BSP.F
1-1/2 BSP.F
1-1/2, 2
FGM-01X-1090
FGM-02-2090
FGM-02X-2090
FGM-02Y-2090
FGM-03-2090
FGM-03X-2090
FGM-03Y-2090
FGM-03Z-2090
FGM-06X-2090
FGM-06Y-2090
FGM-06Z-2090
FGM-10Y-2090
1/4 NPT
1/4 NPT
3/8 NPT
1/2 NPT
3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 NPT
1-1/4 NPT
1-1/2 NPT
1-1/2, 2
0.8 (1.8)
37 (81.6)
Thread
Size
Thread
Size
Sub-plate
Sub-plates are available. Specify the sub-plate model number from
the table above. When sub-plates are not used, the mounting surface
should have a good machined finish.
FGM-10Y is special type sub-plate to be used with pipe flange. When
ordering FGM-10Y, specify pipe flange kit in addition to FGM-10Y
referring to F3 pipe flange kits Catalogue (No. Pub. EC-3001).
Instructions
The minimum differential pressure between inlet and outlet port is required to obtain the optimum pressure com-
pensation. It varies according to the flow rate to be set. For details, please refer to the performance curves.
Min. required pressure difference
Check valve pressure drops vary with flow rates. If models with check valves are used, see free flow pressure drop
characteristics.
Free flow
Loosen the locking screw and turn the flow adjustment dial clockwise for increase, and anti-clockwise for decrease.
The dial makes about 4 revolutions from zero to full flow and the valve opening is indicated on the revolution indicator.
(Refer to characteristics of "Metred Flow vs. Dial Position").
After flow adjustments, tighten the locking screw.
Flow adjustment
[F
G-01]
Loosen the locking screw and turn the flow adjustment handle clockwise for increase, and anti-clockwise for decrease.
Open condition is indicated in digital-scale in built-in revolution indicator (Refer to the characteristics of "Metred
Flow vs. Dial Position").
After flow adjustments, tighten the locking screw.
[F
G-02, 03, 06, 10]
To carry out flow adjustments by as small degree as 2 L/min (.53 U.S.GPM) or less, be sure to use a line filter of
10
μ
m or finer and install it near the valve inlet.
Line filter
Flow Control (and Check) Valves
-01/02/03/06/10
FG
FCG
No.3
Mounting surface:
F
G-02: ISO 6263-AB-06-4-B
F
G-03: ISO 6263-AK-07-2-A
FLOW
CONTROLS
Installation Drawings
FG
FCG
-02
FG
FCG
-03
116
(4.57)
145
(5.71)
Model
No.
C
Dimensions mm (Inches)
96
(3.78)
125
(4.92)
D
76.2
(3.00)
101.6
(4.00)
E
38.1
(1.50)
50.8
(2.00)
F
9.9
(.39)
11.7
(.46)
H
104.5
(4.11)
125
(4.92)
J
82.6
(3.25)
101.6
(4.00)
K
44.3
(1.74)
61.8
(2.43)
L
24
(.94)
29.8
(1.17)
N
9.9
(.39)
11.7
(.46)
P
123
(4.84)
152
(5.98)
Q
69
(2.72)
98
(3.86)
S
40
(1.57)
64
(2.52)
T
23
(.91)
41
(1.61)
U
8.8
(.35)
11
(.43)
V
39
(1.54)
63
(2.48)
X
14
(.55)
17.5
(.69)
W
1
2
Y
2
1
0
9
8
2
4
3
8
7
6
1
5.5(.22)
Dia. Through
9(.35)
Dia. Spotface
4 Places
324
INC.
Fully Extended
46
(1.81)
Mounting Surface
(O-Rings Furnished)
N
X
Locking Screw
2(.08)
Hex. Soc.
Dia.
D
"
V
" Dia. Through
"
W
" Dia. Spotface
4 Places
Controlled Flow Inlet or
Reversed Free Flow Outlet Port
Flow Adjustment Handle
Controlled Flow Outlet or
Reversed Free Flow Inlet Port
L
K
J
U
T
S
Q
Locking Screw
2.5(.10)
Hex. Soc.
Tightening Torque:
0.25 - 0.3 Nm
(2.2 - 2.7 IN. lbs.)
Revolution Indicator
81.5(3.21)
66
(2.60)
51
(2.01)
25.5
(1.00)
7.5
(.30)
INC.
Flow Adjustment Dial
Controlled Flow Inlet or
Reversed Free Flow Outlet Port
Pressure Compensator
Stroke Adjustment
(Only for
FG
FCG
-01-
-N
)
13(.51)
Dia.
16.5
(.65)
31
(1.22)
7.5
(.30)
43
(1.69)
58
(2.28)
3(.12)
Mounting Surface
(O-Rings Furnished)
Locating Pin
4(.16)
Dia.
5
(.20)
17
(.67)
44
(1.73)
45
(1.77)
53.5
(2.11)
Fully Extended
84(3.31)
Controlled Flow
Outlet or
Reversed Free Flow
Inlet Port
Locating Pin
6(.24)
Dia.
"
Y
" Places
C
Fully Extended
E
F
H
Pressure Compensator
Stroke Adjustment
(Only for
FG
FCG
-
-
-N
)
Revolution Indicator
14(.55)
Dia.
P
6
(.24)
22.5
(.89)
Dia.
FG/FCG-01-
-
-11/1190
Flow Control (and Check) Valves
-01/02/03
FG
FCG
No.4
FG/FCG-02-30-
-30/3090, FG/FCG-03-125-
-30/3090
DIMENSIONS IN
MILLIMETRES (INCHES)
Mounting surface:
F
G-06: ISO 6263-AP-08-2-A
FLOW
CONTROLS
D
Installation Drawings
FG
FCG
-06
FG
FCG
-10
198
(7.80)
267
(10.51)
Model
No.
C
Dimensions mm (Inches)
180
(7.09)
244
(9.61)
D
17
(.67)
23.5
(.93)
H
146.1
(5.75)
196.9
(7.75)
E
73
(2.87)
98.5
(3.88)
F
174
(6.85)
228
(8.98)
J
133.4
(5.25)
177.8
(7.00)
K
99
(3.90)
144.5
(5.69)
L
44
(1.73)
61
(2.40)
N
20.3
(.80)
25
(.98)
P
184
(7.24)
Q
130
(5.12)
160
(6.30)
S
65
(2.56)
85
(3.35)
U
16
(.63)
18
(.71)
V
7
(.28)
10
(.39)
W
17.5
(.69)
21.5
(.85)
X
26
(1.02)
32
(1.26)
Y
9
(.35)
7.5
(.30)
Z
103
(4.06)
135
(5.31)
a
214
(8.43)
105
(4.13)
137
(5.39)
T
21
1
INC.
Fully Extended "
C
"
46
(1.81)
Mounting Surface
(O-Rings Furnished)
N
a
Locating Pin
"
V
" Dia.
2 Places
Locking Screw
2(.08)
Hex. Soc.
Dia.
D
H
F
E
"
X
" Dia. through
"
Y
" Dia. Spotface
4 Places
Pressure Compensator
Stroke Adjustment
(Only for
FG
FCG
-
-
-N
)
Controlled Flow Inlet or
Reversed Free Flow Outlet Port
Only for Flow Control and Check Valves
Z
(
FCG-
-
-N
)
Flow Adjustment Handle
Controlled Flow Outlet or
Reversed Free Flow Inlet Port
Revolution
Indicator
W
P
L
K
J
U
T
S
Q
FG/FCG-06-250-
-30/3090
FG/FCG-10-500-
-30/3090
No.5
Flow Control (and Check) Valves
-06/10
FG
FCG
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
Installation Drawings
"
A
" Thd.
Sub-plate
Model Numbers
"
B
" Thd.
CD
"
A
" Thd.
Sub-plate
Model Numbers
"
B
" Thd.
CD
FGM-02-20
FGM-02-2080
FGM-02-2090
FGM-02X-20
FGM-02X-2080
FGM-02X-2090
FGM-02Y-20
FGM-02Y-2080
FGM-02Y-2090
Rc 1/4
1/4 BSP.F
1/4 NPT
Rc 3/8
3/8 BSP.F
3/8 NPT
Rc 1/2
1/2 BSP.F
1/2 NPT
5/16-18 UNC
11.0 (.43)
11.7 (.46)
11.0 (.43)
14.0 (.55)
15.2 (.60)
14.0 (.55)
14.0 (.55)
15.0 (.59)
14.0 (.55)
FGM-01X-10
FGM-01X-1080
FGM-01X-1090
Rc 1/4
1/4 BSP.F
1/4 NPT
M5
M5
No.10-24 UNC
14 (.55)
14 (.55)
15 (.59)
34.5 (1.36)
30.0 (1.18)
34.5 (1.36)
M8
5/16-18 UNC
M8
5/16-18 UNC
M8
18 (.71)
14 (.55)
18 (.71)
14 (.55)
18 (.71)
14 (.55)
EFH
54
(2.13)
51
(2.01)
11.1
(.44)
14
(.55)
25
(.98)
35
(1.38)
D
H
F
E
9
(.35)
18.5
(.73)
36
(1.42)
51
(2.01)
6
(.24)
5(.20)
Dia.
8(.31)
Deep
43
(1.69)
55
(2.17)
"
B
" Thd. "
C
" Deep
4 Places
6(.24)
Dia.
2 Places
"
A
" Thd. (From Rear)
2 Places
16.5
(.65)
14
(.55)
34.5
(1.36)
5.5(.22)
Dia. Through
9(.35)
Dia. Spotface
4 Places
63
(2.48)
76
(2.99)
88
(3.46)
12.5
(.49)
6
(.24)
22
(.87)
17
(.67)
14
(.55)
7(.28)
Dia.
10(.39)
Deep
"
B
" Thd. "
C
" Deep
4 Places
"
D
" Dia. 2 Places
78
(3.07)
106
(4.17)
9.5
(.37)
31.9
(1.26)
54
(2.13)
76.2
(3.00)
79.4
(3.13)
8.8(.35)
Dia. Through
14(.55)
Dia. Spotface
4 Places
"
A
" Thd. (From Rear)
2 Places
16
(.63)
96
(3.78)
120
(4.72)
140
(5.51)
22
(.87)
10
(.39)
23.8
(.94)
11.1
(.44)
11.5
(.45)
52.4
(2.06)
82.6
(3.25)
FGM-01X-10/1080/1090
Sub-plate for
Flow Control (and Check) Valves
No.6
FGM- -20/2080/2090
02
02X
02Y
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
D
Installation Drawings
"
A
" Thd.Sub-plate Model Numbers "
B
" Thd.
CD
FGM-03-20
FGM-03-2080
FGM-03-2090
FGM-03X-20
FGM-03X-2080
FGM-03X-2090
FGM-03Y-20
FGM-03Y-2080
FGM-03Y-2090
FGM-03Z-20
FGM-03Z-2080
FGM-03Z-2090
Rc 3/8
3/8 BSP.F
3/8 NPT
Rc 1/2
1/2 BSP.F
1/2 NPT
Rc 3/4
3/4 BSP.F
3/4 NPT
Rc 1
1 BSP.F
1 NPT
3/8-16 UNC
M10
EFH
75
(2.95)
20.6
(.81)
11.1
(.44)
3/8-16 UNC
M10
3/8-16 UNC
M10
3/8-16 UNC
M10
21 (.83)
18 (.71)
21 (.83)
18 (.71)
J
86.5
(3.41)
K
25
(.98)
14.0 (.55)
15.0 (.59)
14.0 (.55)
17.5 (.69)
19.0 (.75)
17.5 (.69)
70
(2.76)
25.6
(1.01)
16.1
(.63)
81.5
(3.21)
40
(1.57)
23.0 (.91)
"
A
" Thd.Sub-plate Model Numbers "
B
" Thd.
CD
FGM-06X-20
FGM-06X-2080
FGM-06X-2090
FGM-06Y-20
FGM-06Y-2080
FGM-06Y-2090
FGM-06Z-20
FGM-06Z-2080
FGM-06Z-2090
Rc 1
1 BSP.F
1 NPT
Rc 1-1/4
1-1/4 BSP.F
1-1/4 NPT
Rc 1-1/2
1-1/2 BSP.F
1-1/2 NPT
5/8-11 UNC
M16
EFH
35 (1.38)
30 (1.18)
JK
34
(1.34)
99
(3.90)
23
(.91)
60
(2.36)
40
(1.57)
99
(3.90)
22.2
(.87)
104.8
(4.13)
18
(.71)
45
(1.77)
35
(1.38)
104.8
(4.13)
5/8-11 UNC
M16
5/8-11 UNC
M16
35 (1.38)
30 (1.18)
35 (1.38)
30 (1.18)
21 (.83)
18 (.71)
21 (.83)
18 (.71)
14.2
(.56)
20(.79)
Dia.
15(.59)
Deep 2 Places
"
B
" Thd. "
C
" Deep
4 Places
"
A
" Thd. (From Rear)
2 Places
11(.43)
Dia. Through
17.5(.69)
Dia. Spotface
4 Places
17(.67)
Dia.
10(.39)
Deep
2 Places
"
B
" Thd. "
C
" Deep
4 Places
17.5(.69)
Dia. Through
26(1.02)
Dia. Spotface
4 Places
"
A
" Thd. (From Rear)
2 Places
102.4(4.03)
101.6(4.00)
75(2.95)
E
F
20.6
(.81)
0.8
(.03)
"
D
" Dia. 2 Places
101.6
(4.00)
130
(5.12)
20
(.79)
K
11.1
(.44)
H
28.6
(1.13)
J
86.5
(3.41)
125(4.92)
146(5.75)
168(6.61)
21.5(.85)
11(.43)
146.1(5.75)
144.4(5.69)
D
104.8
(4.13)
E
22.2
(.87)
1.6
(.06)
52
(2.05)
29(1.14)
Dia.
2 Places
24
(.94)
126
(4.96)
174
(6.85)
H
F
20.3
(.80)
12.7
(.50)
41.3
(1.63)
104.8
(4.13)
133.4
(5.25)
180(7.09)
212(8.35)
250(9.84)
35(1.38)
19(.75)
K
J
33.2
(1.31)
03
03X
03Y
03Z
FGM- -20/2080/2090
Sub-plate for
Flow Control (and Check) Valves
No.7
06X
06Y
06Z
FGM- -20/2080/2090
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
Installation Drawings
FGM-10Y-20
FGM-10Y-2090
M20
3/4-10 UNC
M16
5/8-11 UNC
32 (1.26)
32 (1.26)
32 (1.26)
34 (1.34)
"
A
" Thd.
Sub-plate
Model Numbers
"
B
" Thd.
CD
34.9
(1.37)
73
(2.87)
1.6
(.06)
140
(5.51)
68.5
(2.70)
144.5
(5.69)
196.9
(7.75)
198.4
(7.81)
73
(2.87)
73
(2.87)
17.3
(.68)
"
A
" Thd. "
C
" Deep
4 Places
36
(1.42)
29
(1.14)
55.5
(2.19)
144.5
(5.69)
177.8
(7.00)
11
(.43)
20(.79)
Dia.
15(.59)
Deep
2 Places
228
(8.98)
250
(9.84)
"
B
" Thd. "
D
" Deep
8 Places (From Rear)
43.5(1.71)
Dia.
2 Places
73
(2.87)
48(1.89)
Dia.
2 Places
244
(9.61)
284
(11.18)
334
(13.15)
45
(1.77)
25
(.98)
21.5(.85)
Dia. Through
32(1.26)
Dia. Spotface
4 Places
Pipe Flange
100
(3.94)
SQ.
80
(3.15)
50
(1.97)
FGM-10Y-20/2090
Sub-plate for
Flow Control (and Check) Valves
No.8
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
D
Performance Characteristics
L/min
8.2
U.S.GPM
8.0
7.8
4.2
4.0
3.8
0.022
0.020
0.018
.0050
.0055
1.00
1.05
1.10
2.05
2.10
2.15
0
4
2
6 8 10 12 14 MPa
0
500 1000 1500 2000 PSI
Flow Rate
Differential Pressure
0
5
10 15 20 21 MPa
0
1000 2000 PSI
Differential Pressure
3000
.0050
.0060
2.0
2.1
2.2
1.00
1.05
1.10
.0055
0.018
0.022
7.6
8.0
8.4
3.8
4.0
4.2
0.020
L/min
U.S.GPM
Flow Rate
0
40
20
60 80 100 120 140
2
mm /s
0
100 300 500 SSU
Viscosity
160
700
0
40
20
60 80 100 120 140
2
mm /s
100 300 500 SSU
Viscosity
160
700
0
0
40
20
60 80 100 120 140
2
mm /s
100 300 500 SSU
Viscosity
160
700
0
0
40
20
60 80 100 120 140
2
mm /s
100 300 500 SSU
Viscosity
160
700
0
0
40
20
60 80 100 120 140
2
mm /s
100 300 500
SSU
Viscosity
160
700
0
.0140
8.00
0.047
0.053
28.5
30.0
31.5
7.6
8.0
8.4
0.050
L/min
U.S.GPM
Flow Rate
7.50
2.2
2.1
2.0
.0135
.0130
.0125
.90
32
33
34
12.5
13.0
13.5
.95
3.3
3.7
119
125
131
47.5
50.0
52.5
3.5
L/minU.S.GPM
Flow Rate
2.6
64
66
68
38
40
42
2.8
9
11
240
250
260
140
150
160
10
L/minU.S.GPM
Flow Rate
2.4
13.0
130
132
134
52
53
54
13.5
48
52
490
500
510
195
200
205
50
U.S.GPM
Flow Rate
L/min
0
5
10 15 20
21
MPa
0
1000 2000 PSI
Differential Pressure
3000
0
5
10 15 20
21
MPa
0
1000 2000 PSI
Differential Pressure
3000
0
5
10 15 20
21
MPa
0
1000 2000 PSI
Differential Pressure
3000
L/min
32
U.S.GPM
30
28
8.2
8.0
7.8
0.52
0.50
0.48
.130
.135
2.05
2.10
2.15
7.5
8.0
Flow Rate
8.5
L/min
130
U.S.GPM
125
120
55
50
45
3.5
3.0
2.5
.8
.9
12
13
14
31
33
Flow Rate
.7
250
U.S.GPM
245
240
155
150
145
11
10
9
38
40
64
66
Flow Rate
2.75
2.50
65
L/min
500
U.S.GPM
510
490
255
250
245
52
50
48
65
66
128
Flow Rate
13.5
13.0
132
L/min
67
No.9
Flow Control (and Check)Valves
-01/02/03/06/10
FG
FCG
Metred Flow vs. Differential Pressure Metred Flow vs. Viscosity
-01
FG
FCG
-01
FG
FCG
-02
FG
FCG
-02
FG
FCG
-03
FG
FCG
-03
FG
FCG
-06
FG
FCG
-06
FG
FCG
-10
FG
FCG
-10
FG
FCG
FLOW
CONTROLS
Performance Characteristics
0
1
Dial Position
234
0
100
Handle Position
200 300 400 500
0
100
Handle Position
200 300 400 500
0
100
Handle Position
200 300 400 500 600
0
100
Handle Position
200 300 400 500 600
8
U.S.GPM
6
4
2
0
0
Flow Rate
0.5
1.0
1.5
2.0
2.25
L/min
120
100
0
80
60
40
20
30
0
20
10
35
U.S.GPM
L/min
140
L/min
Flow Rate
6
0
4
2
8
U.S.GPM
25
0
10
30
5
20
15
Flow Rate
400
0
300
200
100
120
100
0
80
60
40
20
140
U.S.GPM
500
L/min
Flow Rate
200
0
150
100
50
60
50
0
40
30
20
10
70
U.S.GPM
250
L/min
-01-4
FG
FCG
-01-8
FG
FCG
Flow Rate
0
Flow Rate
Differential Pressure
0.7
0
0.6
0.4
0.2
100
PSI MPa
12345678
0 0.5 1.0 1.5 2.0 2.5
U.S.GPM
80
60
40
20
0
L/min
0
Flow Rate
51015202530
012 5 78
U.S.GPM
L/min
34 6
Differential Pressure
0
0.6
0.4
0.2
PSI MPa
80
60
40
20
0
Differential Pressure
0
1.5
1.2
0.9
PSI
200
150
100
50
0
0.6
0.3
MPa
0
Flow Rate
25 50 75 100 125
0 5 10 20 30 35
U.S.GPM
L/min
15 25
0
Flow Rate
50 100 150 200 250
01020406070
U.S.GPM
L/min
30 50
0
Flow Rate
100 200 300 400 500
0 20 40 80 120 140
U.S.GPM
L/min
60 100
Differential Pressure
1.0
0
0.6
0.4
0.2
125
PSI
MPa
100
75
50
25
0
0.8
150
Differential Pressure
1.4
0
0.8
0.4
PSI
MPa
100
50
0
1.2
200
150
-01
FG
FCG
-02
FG
FCG
-03
FG
FCG
-06
FG
FCG
-10
FG
FCG
-01
FG
FCG
-02
FG
FCG
-03
FG
FCG
-06
FG
FCG
-10
FG
FCG
Flow Control (and Check) Valves
-01/02/03/06/10
FG
FCG
No.10
Metred Flow vs. Dial Position
Min. Required Pressure Difference
FLOW
CONTROLS
D
Performance Characteristics
0
46
2
8101214L/min
Free Flow
0
1.0 1.50.5 2.0 2.5 3.0 3.5 U.S.GPM4.0
0
10 20 30 40 50 L/min
Free Flow
0
42 6 8 10 U.S.GPM1412
0
100 200 300 400 L/min
Free Flow
0
4020 60 80 U.S.GPM100
0
50 100
150
200 L /min
Free Flow
0
2010 30 40 U.S.GPM50
0
200 400 600 800 L/min
Free Flow
0
10050 150 U.S.GPM200
0.5
0
0.1
0.2
0.3
0.4
PSI
0
20
40
60
80
MPa
0.5
0
0.1
0.2
0.3
0.4
PSI
0
20
40
60
80
MPa
1.0
0
0.2
0.4
0.6
0.8
PSI
0
25
75
100
125
50
150
MPa
0
0.2
0.4
0.6
PSI
0
25
75
100
50
MPa
1.0
0
0.2
0.4
0.6
0.8
PSI
0
25
75
100
125
50
150
MPa
Pressure Drop P
Pressure Drop P
Pressure Drop P
Pressure Drop P
Pressure Drop P
Throttle Fully Open
Throttle Closed
Throttle Fully Open
Throttle Closed
Throttle Fully Open
Throttle Closed
Throttle Fully Open
Throttle Closed
Throttle Fully Open
Throttle Closed
Throttle Fully Open
(FCG-01-8)
(FCG-01-4)
Viscosity
2
mm /s
SSU
Factor
20
98
0.87
40
186
1.03
60
278
1.14
80
371
1.23
100
464
1.30
No.11
Flow Control and Check Valves
FCG-01/02/03/06/10
Pressure Drop for Reversed Free Flow
Hydraulic Fluid: Viscosity
2
35 mm /s (164 SSU)
, Specific Gravity
0.850
For any other viscosity, multiply the factors
in the table below.
For any other specific gravity (G'), the pressure
drop ( P') may be obtained from the formula
below.
P'= P (G'/0.850)
FCG-01 FCG-02
FCG-03 FCG-06
FCG-10
FLOW
CONTROLS
Spare Parts List
Item
SO-NA-P4
SO-BB-P4
SO-NB-P5
SO-NB-P10A
SO-NB-P12
SO-NB-P14
SO-NB-P18
SO-NB-G25
Name of Parts Qty.
O-Ring
Back Up Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
1
1
1
1
1
1
2
1
28
29
30
31
32
33
34
35
Model Numbers Seal Kit Numbers
FG-02
FCG-02
FG-03
FCG-03
Part Numbers
FG
FCG
-02
KS-FG-02-30
KS-FCG-02-30
KS-FG-03-30
KS-FCG-03-30
FG
FCG
-03
Item
SO-NA-P4
SO-NB-P9
SO-NB-P10
SO-NB-P16
SO-NB-P14
SO-NA-P5
SO-NB-P7
Name of Parts Qty.
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
1
2
1
1
1
1
1
23
24
25
26
27
32
38
Part Numbers
Model Numbers Seal Kit Numbers
FG-01
FCG-01
KS-FG-01-11
KS-FCG-01-11
SO-NA-P4
SO-BB-P4
SO-NB-P5
SO-NB-P16
SO-NB-P18
SO-NB-P14
SO-NB-P28
SO-NB-G35
Section X-X
(FG-01 Type)
Section Y-Y
(FCG-01 Type)
Section X-X
(FG/FCG-01-
-N Type)
Section X-X
(FG-
Type)
(FCG-
Type)
Section X-X
(FG/FCG-
-
-N Type)
20
10
27
2
22
6
1
26
8
9
15
211812
14 19 13
11
16
23 3
4
5
25
7
24
17
Y
X
Y
X
35
38
36
37
33
34
29
27
32
20 28 30
31
8
23 35
6
7
2
24
34
1
33 12 25
11
27
26
10 29 28
4 5
32
3
9
22
X
X
17
19
31
20
21
14
30
13
16
15
33
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.
CAUTION
List of Seals
Note:When ordering the seals, please specify the seal kit number from the table right.
List of Seal Kits
FG
FCG
-01-
-
-11/1190
Flow Control (and Check) Valves
-01/02/03
FG
FCG
No.12
List of Seals
Note: When ordering the seals, please specify the
seal kit number from the table below.
List of Seal Kits
FG/FCG-02-30-
-30/3090
FG/FCG-03-125-
-30/3090
FLOW
CONTROLS
Spare Parts List
D
Item
SO-NA-P4
SO-BB-P4
SO-NB-P21
SO-NB-P32
SO-NB-P34
SO-NB-P50
SO-NB-P24
Name of Parts Qty.
O-Ring
Back Up Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
1
1
1
2
1
3
1
34
35
36
37
39
40
47
Model Numbers Seal Kit Numbers
FG-06
FCG-06
FG-10
FCG-10
Part Numbers
SO-NA-P4
SO-BB-P4
SO-NB-P34
SO-NB-P48
SO-NB-P50
SO-NB-G75
SO-NB-P32
FG
FCG
-06
KS-FG-06-30
KS-FCG-06-30
KS-FG-10-30
KS-FCG-10-30
FG
FCG
-10
Section X-X
(FG-
Type)
Section X-X
(FCG-
Type)
X
X
8 40
6
4
2
40
9
36
10
42 41
1
43 45
47
46
26
1
14
30
15
37
27
11 35
34
5
17
7
39
3 23
No.13
When making replacement of seals, please do it
carefully after reading through the relevant
instructions in the Operator's Manual.
CAUTION
List of Seals
Note) When ordering the seals, please specify the seal kit number
from the table right.
List of Seal Kits
FG/FCG-06-250-
-30/3090
FG/FCG-10-500-
-30/3090
Flow Control (and Check) Valves
-06/10
FG
FCG
FLOW
CONTROLS
Specifications / Model Number Designation
Model Number Designation
Model Numbers
30 (7.9)
125 (33)
250 (66)
500 (132)
kg (lbs.)
Approx. Mass
MPa (PSI)
Min. Pilot
Pressure
L/min (U.S.GPM)
Max. Metred
Flow Capacity
L/min (U.S.GPM)
Min. Metred
Flow Capacity
MPa (PSI)
Max.
Operating Pressure
0.05 (.013)
0.2 (.053)
2 (.53)
4 (1.06)
13 (28.7)
17 (37.5)
32 (70.6)
61 (135)
21
(3050)
1.5
(220)
FHG/FHCG-02-30-
-12
FHG/FHCG-03-125-
-12
FHG/FHCG-06-250-
-12
FHG/FHCG-10-500-
-12
-12
Design
Number
Design Standards
12
-N
Pressure
Compensator
Stroke Adj.
N:
Applicable
only for Pres.
Compensator
Stroke
Adjustment
(Option -
Omit if not
required)
-02 -30
Max.
Metred Flow
Valve
Size
02
03
06
10
30 :
30 (7.9)
125 :
125 (33)
500 :
500 (132)
Special
Seals
for
Phos-
phate
Ester
Type
Fluids
(Omit
if not
re-
quired)
F:
FH:
Pilot
Operated
Flow
Control
Valves
F- FHC
Special
Seals
Series
Number
FHC:
Pilot
Operated
Flow
Cont. &
Check
Valves
G
Type of
Mounting
G:
Sub-plate
Mounting
L/min
(U.S.GPM)
250 :
250 (66)
12
12
12
None:
Japanese Std.
"JIS"
90:
N.American
Design Std.
80:
European
Design Std.
-O
With
No
Pilot
Valve
-A100
Coil
Type
-N
Type of
Electrical
Connections
O:
Without
Pilot
Valve
AC:
A100
A120
A200
A240
DC:
D12
D24
D48
AC
DC:
R100
R200
None:
Terminal Box
Type
N:
With Plug-in
Connector (Din)
N:
With Plug-in
Connector (Din)
Graphic Symbols
FHG
FHCG
T
P
A
O
M
B
A
O
M
B
TP
No.14
Pilot Operated Flow Control (and Check) Valves
Specifications
Sub-plate Mounting
-02/03/06/10
FHG
FHCG
Either solenoid operated directional valve (DSG-01) or modular valve (MSW-01) can be used as a pilot valve.
If no pilot valve is required, there is no needs to specify the coil type and the electrical connection type of solenoid operated directional valve.
FLOW
CONTROLS
Solenoid Ratings / Attachment / Option / Sub-plate
D
2.3 (5.1)
2.3 (5.1)
3.1 (6.8)
3.9 (8.6)
3.9 (8.6)
5.7 (12.6)
5.7 (12.6)
12.5 (27.6)
16 (35.3)
16 (35.3)
Valve
Model
Numbers
-02
FHG
FHCG
-03
FHG
FHCG
-06
FHG
FHCG
-10
FHG
FHCG
Japanese Standard "JIS"
Sub-plate
Model No.
Thread Size
European Design Std.
Sub-plate
Model No.
Thread Size
Sub-plate
Model No.
Thread Size
N. American Design Std.
Approx.
Mass
kg (lbs.)
FGM-02-20
FGM-02X-20
FGM-02Y-20
FGM-03-20
FGM-03X-20
FGM-03Y-20
FGM-03Z-20
FGM-06X-20
FGM-06Y-20
FGM-06Z-20
FGM-10Y-20
Rc 1/4
Rc 3/8
Rc 1/2
Rc 3/8
Rc 1/2
Rc 3/4
Rc 1
Rc 1
Rc 1-1/4
Rc 1-1/2
1-1/2, 2
FGM-02-2080
FGM-02X-2080
FGM-02Y-2080
FGM-03-2080
FGM-03X-2080
FGM-03Y-2080
FGM-03Z-2080
FGM-06X-2080
FGM-06Y-2080
FGM-06Z-2080
FGM-10Y-20
1/4 BSP.F
3/8 BSP.F
1/2 BSP.F
3/8 BSP.F
1/2 BSP.F
3/4 BSP.F
1 BSP.F
1 BSP.F
1-1/4 BSP.F
1-1/2 BSP.F
1-1/2, 2
FGM-02-2090
FGM-02X-2090
FGM-02Y-2090
FGM-03-2090
FGM-03X-2090
FGM-03Y-2090
FGM-03Z-2090
FGM-06X-2090
FGM-06Y-2090
FGM-06Z-2090
FGM-10Y-2090
1/4 NPT
3/8 NPT
1/2 NPT
3/8 NPT
1/2 NPT
3/4 NPT
1 NPT
1 NPT
1-1/4 NPT
1-1/2 NPT
1-1/2, 2 37 (81.6)
100
100
110
240
200
200
220
12
24
48
100
200
50
60
50
60
50
60
50
60
A100
A120
A200
A240
D12
D24
D48
R100
R200
50/60
29
29
2.42
2.14
2.35
2.02
1.78
1.21
1.07
1.18
1.01
0.89
0.51
0.37
0.44
0.42
0.31
0.25
0.19
0.22
0.21
0.15
2.45
1.23
0.61
0.33
0.16
120
Electric Source
AC
DC
(K Series)
AC DC Rectified
Coil Type
Frequency
(Hz)
Source
Rating
Serviceable
Range
Inrush (A) Holding (A) Power (W)
Voltage (V) Current & Power at Rated Voltage
80 - 110
90 - 120
96 - 132
108 - 144
160 - 220
180 - 240
192 - 264
216 - 288
10.8 - 13.2
21.6 - 26.4
43.2 - 52.8
90 - 110
180 - 220
Valve Model Numbers
Socket Head Cap Screw
Japanese Std. "JIS" & European Design Std. N. American Design Std.
Qty.
FHG/FHCG-02
FHG/FHCG-03
FHG/FHCG-06
FHG/FHCG-10
M8 50 Lg.
M10 75 Lg.
M16 130 Lg.
M20 160 Lg.
×
4
4
4
4
5/16-18 UNC 2 Lg.
3/8-16 UNC 3 Lg.
5/8-11 UNC 5 Lg.
3/4-10 UNC 6-1/2 Lg.
×
×
×
×
×
×
×
No.15
Sub-plate
Sub-plates are available. Specify the sub-plate model number from
the table above. When sub-plates are not used, the mounting surface
should have a good machined finish.
FGM-10Y is special type sub-plates to be used with pipe flange. When
ordering FGM-10Y, specify the pipe flange kit in addition to FGM-10Y
referring to F3 pipe flange kits Catalogue (No. Pub. EC-3001).
Pilot Operated Flow Control (and Check) Valves
-02/03/06/10
FHG
FHCG
Solenoid Ratings
Inrush current in the above table shows rms values at maximum stroke.
Attachment
Option
Can reduce jumping at the start of the actuator.
Mounting Bolts
Pres. compensator stroke adjustment
Sub-plates are common with flow control valves. For dimensions, see
pages 6 to 8.
The coil type numbers in the shaded column are handled as optinal extras.
In case these coils are required to be chosen, please confirm the time of
delivery with us before ordering.
FLOW
CONTROLS
1
3
2
44
2
4
1
3
Instructions
Time
Flow Rate
On
Off Off
Solenoid
Signal
No.16
Pilot Operated Flow Control (and Check) Valves
-02/03/06/10
FHG
FHCG
Instructions
While the solenoid operated directional valve on ( shown below), the flow rate is at the level set by the maximum
flow adjustment screw and the actuator operates at the maximum speed setting. Turning the adjustment screw clock-
wise causes the flow rate to decrease.
While the solenoid operated directional valve off ( shown below), the flow rate is set by the minimum flow adjust-
ment screw and the actuator operates at the minimum speed setting. Turning the adjustment screw clockwise causes
the flow rate to increase.
When the solenoid operated directional valve is turned on ( shown below), the flow rate is shifted from minimum
to maximum and the actuator speed is also shifted likewise. The switching time can be set by the pilot flow adjustment
dial (for acceleration). Turning the adjustment dial clockwise causes the pilot flow rate to decrease.
When the solenoid operated directional valve is turned off ( shown below), the flow rate is shifted from maximum
to minimum and the actuator speed is also shifted likewise. The switching time can be set by the pilot flow adjustment
dial (for deceleration). Turning the adjustment dial clockwise causes the pilot flow rate to decrease.
Control patterns and flow rate adjustment
The minimum differential pressure between inlet and outlet port is required to obtain the optimum pressure com-
pensation. It varies according to the flow rate to be set. For details, please refer to the performance curves.
Min. required pressure difference
Check valve pressure drops vary with flow rates. If models with check valves are used, see free flow pressure drop
characteristics.
Free flow
To carry out flow adjustments by as small degree as 2 L/min (.53 U.S.GPM) or less, be sure to use a line filter of
10
μ
m or finer and install it near the valve inlet.
Line filter
To adjust flow rates, slacken the lock nut or the dial setting screw. After adjustments, tighten the lock nut or the dial.
Tightening of flow adjustment screws and dials
FLOW
CONTROLS
D
Performance Characteristics
0
10 15
5
20 25 30 35 40 45
0
1.0 1.75
mm
0.5 1.5
IN.
Flow Rate
L/min
35
U.S.GPM
7
6
5
2
0
1
0
10
15
20
25
30
5
3
4
8
9
Cylinders Stroke
Min. Metred
Flow Range
Max. Metred
Flow Range
Min. Metred
Flow Range
Max. Metred
Flow Range
Min. Metred
Flow Range
Max. Metred
Flow Range
Min. Metred
Flow Range
Max. Metred
Flow Range
L/min
U.S.GPM
140
40
60
80
100
120
20
0
Flow Rate
30
20
0
35
10
0
10 15
5
20 25 30 35 40 45 mm
0
1.0 1.750.5 1.5
IN.
Cylinders Stroke
0
10 15
5
20 25 30 35 40 45
0
1.0 1.75
mm
0.5 1.5
IN.
Flow Rate
300
U.S.GPM
60
50
40
0
10
0
50
100
150
200
250
20
30
70
80
Cylinders Stroke
L/min
0
10 15
5
20 25 30 35 40 45
0
1.0 1.75
mm
0.5 1.5
IN.
Flow Rate
600
U.S.GPM
100
75
50
0
25
0
100
200
300
400
500
125
150
Cylinders Stroke
L/min
Valve Model No.
-02
FHG
FHCG
-03
FHG
FHCG
-06
FHG
FHCG
-10
FHG
FHCG
-02
FG
FCG
-03
FG
FCG
-06
FG
FCG
-10
FG
FCG
Model No.
No.17
Metred Flow vs. Cylinders Stroke
Other Characteristics
See pages 9 to 11. For reference, the
corresponding model No. of the flow control
valves are shown below.
The following characteristics are the same as for flow
control valves;
Metred Flow vs. Differential Pressure
Metred Flow vs. Viscosity
Min. Required Pressure Difference
Pressure Drop for Reversed Free Flow (only for
models with check valves)
FHG
FHCG
Pilot Operated Flow Control (and Check) Valves
-02/03/06/10
FHG
FHCG
-02
FHG
FHCG
-03
FHG
FHCG
-06
FHG
FHCG
-10
FLOW
CONTROLS
Mounting surface:
FH
G-02: ISO 6263-AK-06-2-A
FH
G-03: ISO 6263-AM-07-2-A
Installation Drawings
-02
Model
Numbers
127.4
(5.02)
114.7
(4.52)
C
Dimensions mm (Inches)
96
(3.78)
125
(4.92)
D
76.2
(3.00)
101.6
(4.00)
E
9.9
(.39)
11.7
(.46)
F
100.6
(3.96)
125
(4.92)
H
82.6
(3.25)
101.6
(4.00)
J
44.3
(1.74)
61.8
(2.43)
K
9
(.35)
11.7
(.46)
L
40
(1.57)
64
(2.52)
N
23
(.91)
41
(1.61)
Q
274.3
(10.80)
303.3
(11.94)
S
69
(2.72)
98
(3.86)
U
209
(8.23)
238
(9.37)
X
162
(6.38)
191
(7.52)
Y
129
(5.08)
158
(6.22)
Z
256
(10.08)
285
(11.22)
V
Model
Numbers
104
(4.09)
133
(5.24)
a
Dimensions mm (Inches)
38.1
(1.50)
50.8
(2.00)
d
8.8
(.35)
11
(.43)
e
14
(.55)
17.5
(.69)
f
39
(1.54)
63
(2.48)
h
1
2
j
FHG/FHCG-02-30-
-
-12
FHG/FHCG-02-30-
-
-1290
FHG/FHCG-03-125-
-
-12
FHG/FHCG-03-125-
-
-1290
Model Numbers
Rc 1/4
1/4 NPT
Rc 1/4
1/4 NPT
n
G 1/2
1/2 NPT
G 1/2
1/2 NPT
t
FHG
FHCG
-03
FHG
FHCG
-02
FHG
FHCG
-03
FHG
FHCG
SOL b
Fully Extended
331(13.03)
Fully Extended
d
C
Controlled Flow Inlet or
Reversed Free Flow
Outlet Port
"
e
" Dia. Through
"
f
" Dia. Spotface
4 Places
Controlled Flow Outlet or
Reversed Free Flow Inlet Port
E
F
D
60
(2.36)
L
H
K
J
45
(1.77)
45.5
(1.79)
DC/R:105(4.13)
AC :95.7(3.77)
DC/R:55(2.17)
AC :45.5(1.79)
Space Needed to Remove
Solenoid-Each End
Electrical Conduit Connection
"
t
" Thd. (Both End)
Manual Actuator
6(.24)
Dia.
Pilot Line
Tank Port "T" "
n
" Thd.
(Rear) Pilot Line
Pressure Port "P"
"
n
" Thd.
INC.
Pilot Flow Adj. Dial
(For Deceleration)
90.3
(3.56)
32
(1.26)
Dia.
40
(1.57)
75
(2.95)
Min. Flow
Adjustment Screw
19(.75)
Hex.
U
INC.
(
S
)
N
h
6
(.24)
Mounting Surface
(O-Rings Furnished)
Locating Pin
6(.24)
Dia.
"
j
" Places
Pressure Compensator
Stroke Adjustment
(Only for
FH
G-
-
-N
)
Q
Fully Extended
20(.79)
a
Z
Y
X
V
Lock Nut
19(.75)
Hex.
INC.
Pilot Flow Adj. Dial
(For Acceleration)
Max. Flow
Adjustment Screw
19(.75)
Hex.
INC.
No.18
Pilot Operated Flow Control (and Check) Valves
-02/03
FHG
FHCG
Terminal Box Type
Note: For dimensions of the valve mounting surface, see the
installation drawing (P. 6 and 7) of the sub-plate used
together.
FHG/FHCG-02-30-
-
-12/1290
FHG/FHCG-03-125-
-
-12/1290
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
D
Installation Drawings
FHG/FHCG-02-30-
-A
-N
FHG/FHCG-03-125-
-A
-N
FHG/FHCG-02-30-
-D
-N
FHG/FHCG-03-125-
-D
-N
FHG/FHCG-02-30-
-R
-N
FHG/FHCG-03-125-
-R
-N
Model Numbers
SS VV XX q
Remarks
Dimensions mm (Inches)
274
(10.79)
262
(10.31)
209
(8.23)
303
(11.93)
291
(11.46)
238
(9.37)
285
(11.22)
273
(10.75)
209
(8.23)
314
(12.36)
302
(11.89)
238
(9.37)
288
(11.34)
266.2
(10.48)
209
(8.23)
317
(12.48)
295.2
(11.62)
238
(9.37)
39
(1.54)
39
(1.54)
53
(2.09)
with AC Solenoid
with DC Solenoid
with AC DC
Solenoid
Model Numbers
FHG/FHCG-02-30-
-
-N
FHG/FHCG-03-125-
-
-N
Thread Size
Japanese Std. "JIS"
Design 12
"
n
" Thd.
Rc 1/4
European Design Std.
Design 1280
"
n
" Thd.
1/4 BSP.F
N.American Design Std.
Design 1290
"
n
" Thd.
1/4 NPT
No.19
SOL b
48.5
(1.91)
DC/R:105(4.13)
AC :95.7(3.77)
Cable Departure
Pilot Line
Tank Port "T"
"
m
" Thd.
(Rear) Pilot Line
Pressure Port "P"
"
m
" Thd.
Three positions of cable departure are
available by loosening "Lock Nut" as shown.
After location, tighten "Lock Nut" with torque
in the range 10.3 to 11.3 Nm (91 - 100 IN.lbs.).
XX
VV
(
SS
)
Cable Applicable:
Outside Dia.
......
8-10 mm (.31 - .39 IN.)
Conductor Area
...... Not Exceeding
2
1.5 mm
(.002 SQ. IN.)
DC/R:152(5.98)
AC :142.7(5.62)
q
Pilot Operated Flow Control (and Check) Valves
-02/03
FHG
FHCG
Models with Plug-in Connector
FHG/FHCG-02-30-
-
-N-12/1280/1290
FHG/FHCG-03-125-
-
-N-12/1280/1290
For other dimensions, refer to "Terminal Box Type".
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
Mounting surface:
FH
G-06: ISO 6263-AP-08-2-A
Installation Drawings
Model
Numbers
66.5
(2.62)
21
(.83)
C
Dimensions mm (Inches)
180
(7.09)
244
(9.61)
D
146.1
(5.75)
196.9
(7.75)
E
17
(.67)
23.5
(.93)
F
174
(6.85)
228
(8.98)
H
133.4
(5.25)
177.8
(7.00)
J
73.1
(2.88)
98.5
(3.88)
K
20.3
(.80)
25.1
(.99)
L
105
(4.13)
137
(5.39)
N
65
(2.56)
85
(3.35)
Q
18
(.71)
23
(.91)
S
335.3
(13.20)
365.3
(14.38)
U
317
(12.48)
347
(13.66)
XY
223
(8.78)
253
(9.96)
ZV
Model
Numbers
190
(7.48)
220
(8.66)
a
Dimensions mm (Inches)
165
(6.50)
195
(7.68)
d
7
(.28)
10
(.39)
e
16
(.63)
18
(.71)
f
17.5
(.69)
21.5
(.85)
hm
FHG/FHCG-06-250-
-
-12
FHG/FHCG-06-250-
-
-1290
FHG/FHCG-10-500-
-
-12
FHG/FHCG-10-500-
-
-1290
Model Numbers
Rc 1/4
1/4 NPT
Rc 1/4
1/4 NPT
q
G 1/2
1/2 NPT
G 1/2
1/2 NPT
r
130
(5.12)
160
(6.30)
270
(10.63)
300
(11.81)
44
(1.73)
61
(2.40)
n
26
(1.02)
32
(1.26)
103
(4.06)
135
(5.31)
t
99
(3.90)
144.5
(5.69)
aa
-06
FHG
FHCG
-10
FHG
FHCG
-06
FHG
FHCG
-10
FHG
FHCG
SOL b
Fully Extended
331(13.03)
Fully
Extended
C
Controlled Flow Inlet or
Reversed Free Flow
Outlet Port
"
h
" Dia. Through
"
m
" Dia. Spotface
4 Places
n
J
60
(2.36)
S
K
E
45
(1.77)
45.5
(1.79)
DC/R:105(4.13)
AC :95.7(3.77)
DC/R:55(2.17)
AC :45.5(1.79)
Space Needed to Remove
Solenoid-Each End
Electrical Conduit Connection
"
r
" Thd. (Both End)
Manual Actuator
6(.24)
Dia.
Pilot Line
Tank Port "T"
"
q
" Thd.
(Rear) Pilot Line
Pressure Port "P"
"
q
" Thd.
INC.
Pilot Flow Adj. Dial
(For Deceleration)
90.3
(3.56)
32
(1.26)
Dia.
40
(1.57)
75
(2.95)
Min. Flow
Adjustment Screw
19(.75)
Hex.
V
INC.
(
U
)
Mounting Surface
(O-Rings Furnished)
Locating Pin
"
f
" Dia.
2 Places
Pressure Compensator
Stroke Adjustment
(Only for
FH
G-
-
-N
)
Q
t
Z
Y
X
N
Lock Nut
19(.75)
Hex.
INC.
Pilot Flow Adj. Dial
(For Acceleration)
Max. Flow
Adjustment Screw
19(.75)
Hex.
INC.
Controlled Flow Outlet or
Reversed Free Flow Inlet Port
D
F
L
H
e
aa
d
a
No.20
Pilot Operated Flow Control (and Check) Valves
-06/10
FHG
FHCG
Terminal Box Type
Note: For dimensions of the valve mounting surface, see the
installation drawing (P. 7 and 8) of the sub-plate used
together.
FHG/FHCG-06-250-
-
-12/1290
FHG/FHCG-10-500-
-
-12/1290
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
D
Installation Drawings
FHG/FHCG-06-250-
-A
-N
FHG/FHCG-10-500-
-A
-N
FHG/FHCG-06-250-
-D
-N
FHG/FHCG-10-500-
-D
-N
FHG/FHCG-06-250-
-R
-N
FHG/FHCG-10-500-
-R
-N
Model Numbers
UU XX YY m
Remarks
Dimensions mm (Inches)
335
(13.19)
323
(12.72)
270
(10.63)
365
(14.37)
353
(13.90)
300
(11.81)
346
(13.62)
334
(13.15)
270
(10.63)
376
(14.80)
364
(14.33)
300
(11.81)
349
(13.74)
327.2
(12.88)
270
(10.63)
379
(14.92)
357.2
(14.06)
300
(11.81)
39
(1.54)
39
(1.54)
53
(2.09)
with AC Solenoid
with DC Solenoid
with AC DC
Solenoid
Model Numbers
Thread Size
FHG/FHCG-06-250-
-
-N
FHG/FHCG-10-500-
-
-N
Japanese Std. "JIS"
Design 12
"
q
" Thd.
Rc 1/4
European Design Std.
Design 1280
"
q
" Thd.
1/4 BSP.F
N.American Design Std.
Design 1290
"
q
" Thd.
1/4 NPT
No.21
SOL b
48.5
(1.91)
DC/R:105(4.13)
AC :95.7(3.77)
Cable Departure
Pilot Line
Tank Port "T"
"
q
" Thd.
(Rear) Pilot Line
Pressure Port "P"
"
q
" Thd.
Three positions of cable departure are
available by loosening "Lock Nut" as shown.
After location, tighten "Lock Nut" with torque
in the range 10.3 to 11.3 Nm (91 - 100 IN.lbs.).
YY
XX
(
UU
)
Cable Applicable:
Outside Dia.
......
8-10 mm (.31 - .39 IN.)
Conductor Area
...... Not Exceeding
2
1.5 mm
(.002 SQ. IN.)
DC/R:152(5.98)
AC :142.7(5.62)
m
Pilot Operated Flow Control (and Check) Valves
-06/10
FHG
FHCG
Models with Plug-in Connector
FHG/FHCG-06-250-
-
-N-12/1280/1290
FHG/FHCG-10-500-
-
-N-12/1280/1290
For other dimensions, refer to "Terminal Box Type".
DIMENSIONS IN
MILLIMETRES (INCHES)
FLOW
CONTROLS
Lead Wire Connection
Terminal Box Type Plug-in Connector Type
Type of
Electrical Conduit
Connection
Electric Source
Terminal
Box Type
Plug-in
Connector
Type
AC DC AC DC Rectified
1
1
3
2
2
3
SOL.
SOL. SOL.
SOL.
SOL.
SOL.
Ground
2-Power Supply
1-Power Supply
Indicator Light Indicator Light
Voltage-Surge
Suppressor
Indicator Light
Voltage-Surge
Suppressor
Rectifier
Circuit
Power
Supply
Common
Ground
Power
Supply
Common
Ground
Power
Supply
Common
Ground
Indicator Light
(Integrated in "N1"
model only)
1-Power
Supply
Ground
2-Power
Supply
1-Power
Supply
Ground
2-Power
Supply
Indicator Light
(Integrated in "N1"
model only)
Voltage-Surge
Suppressor
(Circuit composed
in coil)
1-Power
Supply
Ground
2-Power
Supply
Voltage-Surge
Suppressor
Rectifier
Circuit
Indicator Light
Ground
Power Supply
SOL. b
Details of Receptacle
With DC solenoids, polarity is no question.
Electrical Circuit
No.22
Pilot Operated Flow Control (and Check) Valves
-02/03/06/10
FHG
FHCG
Do not perform wiring while the power is on.
Doing so may result in electric shock, burns or death.
Make the wiring properly. Improper wiring will cause an
irregular movement of the machine, resulting in a grave
accident.
DANGER
FLOW
CONTROLS
Spare Parts List
D
Item
SO-NB-P20
SO-NB-P5
SO-NB-P10A
SO-NB-P12
SO-NB-P14
SO-NB-P18
SO-NB-G25
SO-NB-P9
SO-NB-P10A
SO-NA-P26
SO-BB-P26
SO-NB-P38
Name of Parts Qty.
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Back Up Ring
O-Ring
1
1
1
1
1
2
1
2
2
2
4
2
29
30
31
32
33
34
35
57
58
59
60
61
Model Numbers Seal Kit Numbers
FHG-02
FHCG-02
FHG-03
FHCG-03
Part Numbers
FHG
FHCG
-02
KS-FHG-02-12
KS-FHCG-02-12
KS-FHG-03-12
KS-FHCG-03-12
FHG
FHCG
-03
SO-NB-P20
SO-NB-P5
SO-NB-P16
SO-NB-P18
SO-NB-P14
SO-NB-P28
SO-NB-G35
SO-NB-P9
SO-NB-P10A
SO-NA-P26
SO-BB-P26
SO-NB-P38
Pilot Operated Flow Control (and Check) Valves
-02/03
FHG
FHCG
SOL b
SOL b
63
62
50
52
58
54
53
51
59
60
55
57
49
61
56
11
29
10
4
5
3
32
9
22
X
X
34
23 35
7
8
6 2
24
33
25
12
1
1 17
19
31 21
20
14
33
30 13 16
15
63
(FHG-
Type)
Section X-X
(FHCG-
Type) -
-
-N Type
FHG
FHCG
No.23
When making replacement of seals, please do it carefully after reading
through the relevant instructions in the Operator's Manual.
CAUTION
List of Seals
Note) When ordering the seals, please specify the seal kit number from the
table right. In addition to the above seals, seals for pilot valves are
included in the seal kit.
List of Seal Kits
FHG/FHCG-02-30-
-
-12/1290
FHG/FHCG-03-125-
-
-12/1290
Terminal Box Type Models with Plug-in Connector
FHG/FHCG-02-30-
-
-N-12/1280/1290
FHG/FHCG-03-125-
-
-N-12/1280/1290
Pilot Valves
See page 25 for the pilot valve model numbers to be
used.
FLOW
CONTROLS
Spare Parts List
Item
SO-NB-P20
SO-NB-P21
SO-NB-P32
SO-NB-P34
SO-NB-P50
SO-NB-P24
SO-NB-P9
SO-NB-P10A
SO-NA-P26
SO-BB-P26
SO-NB-P38
Name of Parts Qty.
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
O-Ring
Back Up Ring
O-Ring
1
1
2
1
3
1
2
2
2
4
2
35
36
37
39
40
47
57
58
59
60
61
Model Numbers Seal Kit Numbers
FHG-06
FHCG-06
FHG-10
FHCG-10
Part Numbers
FHG
FHCG
-06
KS-FHG-06-12
KS-FHCG-06-12
KS-FHG-10-12
KS-FHCG-10-12
FHG
FHCG
-10
SO-NB-P20
SO-NB-P34
SO-NB-P48
SO-NB-P50
SO-NB-G75
SO-NB-P32
SO-NB-P9
SO-NB-P10A
SO-NA-P26
SO-BB-P26
SO-NB-P38
SOL b
SOL b
(FHG-
Type)
Section X-X
(FHCG-
Type)
63
50
52
58
54
53
62
49
57
55
61
51
59
60
56
35
7
39
23
14
11
3
5
17
37
27
X
X
26
1
40
8
6
4
2
40
36
9
10
42
41
46
47
43
45
1
63
Section X-X
When making replacement of seals, please do it carefully after reading
through the relevant instructions in the Operator's Manual.
CAUTION
List of Seals
Note) When ordering the seals, please specify the seal kit number from the
table right. In addition to the above seals, seals for pilot valves are
included in the seal kit.
List of Seal Kits
FHG/FHCG-06-250-
-
-12/1290
FHG/FHCG-10-500-
-
-12/1290
Terminal Box Type Models with Plug-in Connector
FHG/FHCG-06-250-
-
-N-12/1280/1290
FHG/FHCG-10-500-
-
-N-12/1280/1290
Pilot Valves
See page 25 for the pilot valve model numbers to be
used.
Pilot Operated Flow Control (and Check) Valves
-06/10
FHG
FHCG