65
ES-08W-X-Y-Z-04-F
1.6
6
E.410.122.E
0.8 2.4
With Filter)
SOLENOID OPERATED VALVE
(Direct-Acting)
3
viscosity, cleanliness, temperature and so on are different, the curve or data will be different.
The performance curve or data is only for reference, as customers' using condition, pressure, flow, hydraulic fluid
Data subject to change.
9
0.8 3.2
12
1.6
l/min0 156
4.0 US gpm2.4
3
Illustrations / detail are
(Spool, 4-Way, 2-Position, Port
15
psi/bar
for reference only.
②
to
③
3 129
73/5
145/10
218/15
290/20
Pressure Drop
Pressure-∆P
Flow-Q
Operating Limits
Pressure
Flow-Q
0
6092/420
1015/70
2030/140
3046/210
4061/280
5076/350
l/min
US gpm4.03.2
①to④
④to①
psi/bar
TECHNICAL DATA
Rated pressure: 210
Rated flow: 5
Cavity-Tooling: 08W-4
Installation torque: 39 - 51
=N)
Rev.240905
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Z
Minimum Voltage Required:
Coils must be ordered separately
Mounting Position: unrestricted
90 % of nominal
Screw-out Knob StyleM
N Non-adjustable
Z OPTIONS
OPERATION
Y
10A Spool 4-Way, 2-Position
Weight: 0.121 (
12.7 mm tube
4A
X STRUCTURE
(Refer To Performance Chart)
TRANSITION:
(Refer To Performance Chart)
4 Ports、20 Watt. Coil
pressure and flow
ON
OFF 20 - 40 ms
30 - 60 ms
depending on
Response time
( T.101.103.E HYDRAULIC FLUID (C)TEMPERATURE )
( T.101.102.E HYDRAULIC FLUID (B)CLEANLINESS )
Hydraulic Fluid Viscosity、Cleanliness、Temperature Level:
Please refer WINNER technical information.
( T.101.101.E HYDRAULIC FLUID (A)VISCOSITY )
M12x1.25
Inlet (With Filter)
3/4"-16UNF-2A
(7/8 inch)
22.22 Hex.
Torque 2 - 3 Nm
Locating
Shoulder
14.27
1
2
4
3
15.87
54
12.7
2
61
Coil EC-04W
3
4
1
2
3
4
1
2