19
Coil EC-19A
ES-11A-X-Y-Z-04
M20x1.5
(7/8 inch)
22.22 Hex.
Torque 3 - 5 Nm
Locating
Shoulder
2
3
1
35.05 (Ref.)
17.45
108.7
0
Pressure
Operating Limits
6092/420
E.314.301.E
1015/70
③
③
2030/140
3046/210
②
SOLENOID OPERATED VALVE
②to
(Spool 3-Way)
②
D
ata subject to change.
psi/bar
to②
5.3
(Direct-Acting)
The performance curve or data is only for reference,
as customers' using condition, pressure, flow, hydraulic fluid
for reference only.
①to
viscosity, cleanliness, temperature and so on are different, the curve or data will be different.
7.9 10.62.6 13.2
0 10
145/10
290/20
435/30
580/40
20 l/min
US gpm
Flow-Q
Pressure-∆P
Pressure Drop
psi/bar
5.3
20
2.6 7.9
5010 40
Illustrations / detail are
to①
30
①to②
50
10.6 13.2 US gpm
l/min
5076/350
②to③
4061/280
40
②to①
30
②to③
Flow-Q
( T.101.102.E HYDRAULIC FLUID (B)CLEANLINESS )
T
ECHNICAL DATA
STRUCTURE
X
( T.101.103.E HYDRAULIC FLUID (C)TEMPERATURE )
P
Max.Operating pressure: 350
Z
19 mm tube
Rev.240507
Ordering Code:
UNIT:mm
Rated flow: 45
Cavity-Tooling: 11A-3
Installation torque: 40 - 50
Weight: 0.280 (
kg
Nm
l/min
bar
unrestricted
90 % of nominal
Spool 3-Way, 2-Position14
Y
OPERATION
OPTIONS
Z
Non-adjustable
Response time
=P)
3D
3 Ports、22 Watt. Coil
pressure and flow
ON
OFF 20 - 40 ms
Minimum Voltage Required:
Coils must be ordered separately
30 - 60 ms
(Refer To Performance Chart)
Mounting Position:
(Refer To Performance Chart)
TRANSITION:
depending on
N
Hydraulic Fluid Viscosity、Cleanliness、Temperature Level:
Please refer WINNER technical information.
( T.101.101.E HYDRAULIC FLUID (A)VISCOSITY )
Push Style
Manual Override
2
13
3 1
2