Pressure- P(bar)
Pressure- P(bar)
16
111
Flow-Q(l/min)
D.354.301.E
10
③Port
)
0
t
o②
(Poppet 3-Way 2-Position Cartridge Style,
Fast acting
SOLENOID OPERATED VALVE
③
to
②
De-energized
②
to
①
Energized
①
De-energized
②
Energized
②
to
20 30 40
10
20
30
40
50
Limits of Application
to
③
Pressure Drop
Flow-Q(l/min)
420
0 10 20 30 40
60
120
180
240
300
360
60
Port
①
to
②
Port②to①
Port
③
to
②
( T.101.102.E HYDRAULIC FLUID (B)CLEANLINESS )
TECHNICAL DATA
STRUCTURE
X
OPERATION
Y
Rated flow: 25
Cavity-Tooling: 11A-3
Performance Chart
=N)
Installation torque: 39-51
2
Z
16 mm tube
Rev.220413
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
54
Fluids-Temperatures: -40 to 120
Internal Leakage Approximately:
Minimum Voltage Required:
Coils must be ordered separately
Mounting Position:
℃
unrestricted
0.15 cc/minute
(3 drops/minute) max. at 350 bar
Weight: 0.235 (
M Screw-out Knob Style
.
90 % of nominal
, 2
3C
3 Ports、26 Watt. Coil
(Direct-Acting)
Response Time
( 1 Closing 30-50 ms
N Non-adjustable
Z
OPTIONS
(Refer To Performance Chart)
→
(Refer To Performance Chart)
2
Direct-Acting Poppet 3-Way
Opening 20-40 ms
)→
2-Position Cartridge Style, Fast acting
3
When de-energized, port
1 is closed and bidirectional flow
between port
2 and port 3 .
When energized, port 3 is closed and bidirectional flow
between port 1 and port
Hydraulic Fluid Cleanliness Level:
Please refer WINNER technical information.
Max.Operating pressure: 350
EP-11A-X-Y-Z-04
2
13
Torque 5-7 Nm
24.0 Hex.
M20x1.5
M16x1.5
Locating
Shoulder
1
3
2
(Ref.)
35.05
17.45
101
Coil EC-16B