19
Coil EC-19A
2
1
(
(Electro-Proportional, Normally Closed)
P=bar
Flow-Q(l/min)
Typical Pressure Drop
① ②
)
(② ①)
Typical Metering Preformance
Command Current, mA
FLOW CONTROL VALVE
Rev.200113
B.352.114
Ordering Code:
UNIT:mm
0-100 LPM
1000
FLOW
Z
NOMINAL CAPACITY
No Reverse Flow Energized
(5 drops/minute) max.at 260 bar
Coils must be ordered separately
bar
l/min
Nm
Installation torque: 60-70
Cavity-Tooling: 16W-2
Rated flow: 100
Max.Operating pressure: 260
OPERATION
Normally-Closed
19 mm tube
2D
X
STRUCTURE
Y
01
Weight:(with Coil) 0.67 kg
(without Coil) 0.43 kg
50
20
10
30
40
160
60
0
40 80 120 200
200
12001000800600
400200(12 V)
(24 V) 600500400
TECHNICAL DATA
300
P:35 bar
250
0
50
100
2 Ports22 Watt. Coil
150
100
P:14 bar
200
P:20 bar
P:50 bar
Flow-Q(l/min)
38.0 Hex.
Torque 3-5 Nm
1-5/16"-12UN-2A
Locating
Shoulder
2
1
The function of screw is
to set zero point.
Please don't adjust by
yourselves.
92 45
1.5
28.6
PEP-16W-X-Y-N-Z