Pressure- P(bar)
16
Torque 5 - 7 Nm
7/8"-14UNF-2A
22.22 Hex.
(7/8 inch)
Locating
Shoulder
(P)
2
1
(T)
100 31.5
15.8
(Pilot Operated Standard Balanced, Low Pressure with No Command)
Pressure Differential vs. Flow
Flow-Q(l/min)
60 100
0 20 40
5
10
15
20
25
30
Pressure adjustment characteristics
at Q=10 LPM (static)
If pressure control beyond the range is required, please
PROPORTIONAL RELIEF VALVE
Rev.240429
B.740.102.E
Ordering Code:
UNIT:mm
P
Y
5 - 210 bar
A
OPTIONS
Z
Coils must be ordered separately
(RECOMMEND PRESSURE RANGE)
(Recommended dither frequency 140 - 300 Hz)
Linearity with dither < 2%
Hysteresis with DC input < 8%
Hysteresis with dither < 4%
Dither should be adjustable between 80 - 300 Hz
Reseat exceeds 85% of cracking pressure
CONTROL PRESSURE RANGES
16 mm tube
2C
(Without Coil)
Installation torque: 35 - 45 Nm
Cavity-Tooling: 10W-2
Rated flow: 95 l/min
Max.Operating pressure: 350 bar
X
OPERATION
TECHNICAL DATA
Weight: 0.240 kg
Manual Override
3 - 70 bar
D
2 - 40 bar
E
Push Style
2 Ports26 Watt. Coil
(30 cc/min./70 bar)
Maximum Leakage Approximately
1400
700
Reduced Pressure (bar)
100 200 300 400 500 600
12001000800600400200(12 V)
(24 V)
1500
750
Command Current, mA
420
300
240
180
120
60
0
Y=A
360
Y=A
Data subject to change.
for reference only.
Illustrations / detail are
contact the Winner sales department.
PRP-10W-X-Y-Z-B
Coil EC-16B
(T)
12
(P)