(Pilot-to-closed, Normally open, balanced poppet, logic element)
and flow.
TECHNICAL DATA
OPERATION
X
Max. Operating pressure: 350 bar
Rated flow: 240 l/min
Cavity-Tooling: 17A-3
Installation torque: 200-215 Nm
Weight: 0.60 kg
Rev.220414
B.706.313.E
Ordering Code:
20.0 bar
UNIT:mm
3S
Flow-Q(l/min)
P=bar
Non-adjustable
OPTIONSZ
N
20
Y
SPRINGS
)
Pressure Differential vs. Flow
Fully Open
All ports will accept 350 bar.
Maximum Leakage Approximately (0.7 cc/min.)
200120400
4
8
12
16
160 24080
20
Recommendation of Minimum Pilot
(7/16"-20UNF-2B)
S04
External SAE-4 Port
every 4000 cycles.
from the pilot area to the vented spring chamber
Approximately 1 drop (0.07 cc) of fluid will pass
Pilot-to-open
3Pressure Required to Shift Valve (Port
We suggest that using above 20 bar pilot pressure at Port 3
when Port 1 and Port 2 are 350 bar.
In order to ensure shifting quickly for every kinds of pressure
LOGIC ELEMENT VALVE
Valve
Pilot
M36x2.0
(1-1/4 inch)
31.7 Hex.
(9/16 inch)
Shoulder
Locating
Z=N OPTION
14.27 Hex.
Z=S04 OPTION
SAE-4 VENT PORT
Valve
3
1
2
30
71
62.8
46.22 (Ref.)
LN-17A-X-Y-Z
2
1
3EXT