FR-23A-X-Y-Z
with 80 LPM inlet
with 160 LPM inlet
pressure compensated
(Vented, Fixed Orifice, Bypass/Restrictive, Pressure Compensated)
PRIORITY FLOW CONTROL VALVE
Valve Set
at 50 L/min.
40
80
100
0
0
350350 210 70 70 210
bypass/restrictive,
at 8 L/min.
2
0
Factory Set Point
60
Valve Set
Typical Performance
higher than bypass
Priority pressure
Vented, Fixed orifice,
higher than priority
B
ypass pressure
with 16 LPM inlet
with 240 LPM inlet
Priority Flow
pressure at priority port.
TECHNICAL DATA
OPERATION
X
Y
Max. Operating pressure: 350 bar
Maximum Inlet Flow: 240 l/min
control setting, the priority port shut off and all flows will go
=L) kg
4F
R
ev.221215
B.341.203.E
Ordering Code:
0080
Example: 8.0 LPM
UNIT:mm
P
riority Flow Ranges: 0.8 - 95 l/min
L
Z
Cavity-Tooling: 23A-4
When pressure at bypass port exceeds the pressure
I
f a momentary impact pressure is needed in the
25%)
O
PTIONS
Approx.
Installation torque: 200 - 215 Nm
A
pprox.
application, please consult our sales department.
W
eight : 0.681 (
).
B
oth priority and bypass flow are usable up to the system
3
K
are satisfied.
operating pressure.
Bypass flow is not available until priority flow requirements
at the priority port (port
Blocking priority flow will also block bypass flow.
N
10% of the requested settingFactory set flow ratings are within
(Adjustment Ranges
0070
0
040
to the bypass port.
2 ) may exceed pressure
Z
Non-adjustable
specified flow)
Leakproof hex.
(Factory set at customer
C
ustomer must specify a flow rating
socket screw.
(Order Code: 6ZAK001)
(
customer must specity flow)
25%)
)
If you need specific flow accuracy, please contact WINNER's
Priority Flow (Port
sales department
Data subject to change.
f
or reference only.
0.75 l/min
Nominal Vent Flow Approximately:
Illustrations / detail are
(Adjustment Ranges
Q=L/min
P=bar
Example: 4.0 LPM
E
xample: 7.0 LPM
Example: 14.0 LPM
Example: 25.0 LPM
Example: 65.0 LPM
Example: 75.0 LPM
Example: 95.0 LPM
0950
0
750
0650
0250
0140
Pressure at the bypass port(port
Handknob with
Lock Konb.
If use pressure at vented port, then it can control the
Before priority port are satisfied by flow, the bypass
shut off. Unless the vented port connects to tank.
When the vented port connects to tank, all flows will go
to the bypass port if inlet pressure over 10.5 bar.
Vent
31.7 Hex.
L=100
Flow Inlet
K=107
1
2
Bypass Flow
increase
(
Z=L Control shown)
Turn adjustment clockwise
4
(1-1/4 inch)
Torque 9 - 10 Nm
Apply CH (5JAA097)
Plastic tamper
flow
resistant cover
3P
riority Flow
to
M
36x2.0
3/8"-24UNF-2A
14.27 Hex. (9/16 inch)
Control Option:
Maximum extension
from locating shoulder.
4.0 Hex.
Locating
Shoulder
30
N=63.4
46.22 (Ref.)