2
3
1
CB-17A-X-Y-Z
Valve
2
from locating shoulder.
to reduce setting and
(L Control shown)
(1 1/4 inch)
1
Load
release load.
Turn screw clockwise
Control Option:
Maximum extension
31.7 Hex.
M36x2
Locating
Shoulder
7046
3
Pilot
TECHNICAL DATA
COUNTERBALANCE VALVE
Rev.160225
B.121.103
Ordering Code:
UNIT:mm
Setting should be 1.3 times maximum
t
o
Pressure Drop
30
25
20
15
10
5
240
180
120
60
0
Pressure- P(bar)
Flow-Q(l/min)
PILOT RATIO
X
3C
3A 1.5 : 1 (with sealed pilot)
3 : 1 (with sealed pilot)
E
16 to 55 bar (25 bar Standard Setting)
25 to 105 bar (70 bar Standard Setting)
SPECIAL PURPOSES(0.3 bar Cracking Pressure)
B
A
70 to 280 bar (210 bar Standard Setting)
25 to 105 bar (70 bar Standard Setting)
ADJUSTMENT RANGES(2 bar Cracking Pressure)
70 to 280 bar (210 bar Standard Setting)
I
H
Y
SPRINGS
Stainless Steel
Cover.
C
Free Flow or Piloted Open
Tamper Resistant
socket screw.
Z
OPTIONS
L
Leakproof hex.
load induced pressure.
Pressure Setting:
Weight: 0.6 kg
Installation torque: 200-215 Nm
Cavity-Tooling: 17A-3
Rated flow: 240 l/min
Max. Setting: 280 bar
Max. Operating pressure: 350 bar
to
30