Locating
Shoulder
Inlet
1
(3/4 inch)
2
Outlet
19.05 Hex.
M16x1.5
Control Option:
Maximum extension
from locating shoulder.
(L Control shown)
L=55
K=71
31
1
2
RP-162A-X-Y-Z
(Pilot Operated Balanced Piston)
suitable for use in cross port relief circuits.
Cover.
TECHNICAL DATA
OPERATION
X
SPRINGS
OPTIONS
Y
Max.Operating pressure: 350 bar
Rated flow: 45 l/min
Cavity-Tooling: 162A-2
Installation torque: 27-33 Nm
Weight: 0.10 kg
RELIEF VALVE
Handknob with
Response Time-Typical (10 ms)
socket screw.
L
ADJUSTMENT RANGES
Rev.160225
B.101.100
Ordering Code:
5 to 210 bar (70 bar Standard Setting)
A
B
UNIT:mm
5 to 28 bar (14 bar Standard Setting)
Q
5 to 105 bar (70 bar Standard Setting)
C
N
W
5 to 420 bar (70 bar Standard Setting)
5 to 55 bar (28 bar Standard Setting)
5 to 315 bar (70 bar Standard Setting)
K
1 to 2 (P to T)
Z
Leakproof hex.
Lock Knob.
20
spool leakage.
350
C
Typical Pressure Rise
If used in cross port relief circuits, consider
Maximum Leakage (30 cc/min./70 bar)
Flow-Q(l/min)
Pressure- P(bar)
0
25
50 75
100
100
200
300
50
150
250
Will accept maximum pressure at port 2;
Stainless Steel
Tamper Resistant
16.6