∆P=14 bar
(Bypass/Pressure compensated)
P=bar
when
higher than bypass
Priority pressure
higher than priority
Priority Flow-Q(l/min)
Bypass pressure
Regulated Flow vs. Load at 105 LPM Inlet
3-Ported
to
p
r
e
s
s
u
r
e
d
r
o
p
Flow-Q(l/min)Flow-Q(l/min)
t
o
p
r
e
s
s
u
r
e
d
r
o
p
t
o
= 10 LPM
to
when = 95 LPM
P=bar
P=bar
100
15
10
5
6040200
20
80
25
100
15
10
5
6040200
20
80
25
140 28021070
210 70
100
80
0
280 140
60
40
20
Port to Port
PRIORITY FLOW CONTROL VALVE
TECHNICAL DATA
Max. Operating pressure: 240 bar
Cavity-Tooling: 16W-3
Installation torque: 60 - 70 Nm
Weight: 0.422 kg
39
Rev.221201
B.321.114.E
Ordering Code:
UNIT:mm
105 LPM nominal
Note:
(Priority Flow 1 - 95 LPM fully adjustable )
) is blocked.
Standard, ∆P=14 bar
SPRING RANGE
N
Y
X
PRIORITY FLOW RANGE
2
Handknob Kit.
T
Z
L
OPTIONS
Three-winged
socket screw.
Leakproof hex.
the bypass port (port
(Order Code: 6ZAK001)
K
Lock Knob.
aluminum locknut.
B
157 LPM max.
Handknob and
3-ported regulated flow 95 LPM
Flow Rate :
Handknob with
:Inlet flow at port
It can be used as a priority-type flow regulator
or a restrictive-type 2-way flow regulator when
Illustrations / detail are
for reference only.
Data subject to change.
FR-16W-X-Y-Z
is blocked.Port 2
3-Ported.
3
2
3
1
2
1
3
1
2
Bypass
Inlet
Torque 9 - 10 Nm
Apply CH (5JAA097)
Plastic tamper
1-5/16"-12UN-2A
Shoulder
Locating
(Z=L Control shown)
4.0 Hex.
3/8"-24UNF-2A
from locating shoulder.
Maximum extension
Control Option:
Flow
resistant cover
32.0 Hex.
Flow
Priority
14.27 Hex. (9/16 inch)
Turn adjustment clockwise
to decrease flow
3
2
30
1
74.4
43