16
240
300
D.151.502
Flow-Q(l/min)
Pressure- P(bar)
0
5 10 15
6
12
18
24
180
120
t
o
30
20
Pressure Drop
Limits of Application
420
Flow-Q(l/min)
Pressure- P(bar)
0 4 8 12 16 20
60
t
o
360
Manual Override
P
TECHNICAL DATA
STRUCTURE
X
OPERATION
Y
Max.Operating pressure: 350
Rated flow: 20
Cavity-Tooling: 08W-2
Max.Installation torque: 25-35
Weight: 0.18
2C
Rev.160623
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
51
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be order
ed separately
Mounting Position:
unrestricted
0.15cc/minute
(3 drops/minute) max.at 210 bar
-Closed Double-Lock
OPTIONS
Z
Non-adjustable
16 mm tube
90 % of nominal
N
2 Ports26 Watt. Coil
Direct-Acting Normally
Port to
Port to
Push Style
SOLENOID OPERATED VALVE
(Direct-Acting Normally-Closed Double-Lock Cartridge Style, Fast-acting)
Torque 5-7 Nm
Torque 25-35 Nm
Hex.24
3/4"-16UNF-2A
2
1
28
12.7
2
84
2
1
EP-08W-X-Y-Z-04
Coil EC-16B