(Poppet 2-Way Double Lock Normally-Closed Cartridge Style)
SOLENOID OPERATED VALVES
D.131.108
Opening
TECHNICAL DATA
STRUCTURE
X
Max.Operating pressure: 350
Rated flow: 150
Cavity-Tooling: 12W-2
Installation torque: 54-66
Weight: 0.23
2A
2 Ports20 Watt. Coil
Rev.120814
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be ordered separately
Mounting Position:
unrestricted
0.15cc/minute
(3
drops/minute) max.at 350 bar
90 % of nominal
Normally-Closed Double Lock
Screw-out Knob Style
M
N
Non-adjustable
Z
OPTIONS
18
15
Y
OPERATION
31
t
o
1601208040
200
150
100
50
0
Time (ms)
Flow-Q(l/min)
Flow-Q(l/min)
Pressure- P(bar)
0 40 80 120 160
3
6
9
12
to
Closing
2
1
Coil EC-04W
EP-12W-X-Y-Z-05
1-1/16"-12UN-2A
Hex.32
Torque 3-4 Nm
2
1
45 65
2
22.22
61