80
D.110.108
Z
OPTIONS
TECHNICAL DATA
STRUCTURE
X
Max.Operating pressure: 350
Rated flow: 150
Cavity-Tooling: 12W-2
Installation torque: 54-66
Weight: 0.23
2A
2 Ports20 Watt. Coil
Rev.120810
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be ordered separately
Mounting Position:
unrestricted
0.15cc/minute
Non-adjustable
Manual Override
P
De-energized ,Nose-in,Side-out Operation
Y
OPERATION
(3 drops/minute) max.at 350 bar
N
10
1601208040
200
150
100
50
0
Time (ms)
Flow-Q(l/min)
Flow-Q(l/min)
Pressure- P(bar)
0 40 80 120 160
2
4
6
8
10
12
Opening
Closing
90 % of nominal
Normally-Open,No Reverse Flow
t
o
T
Push and Twist Style
Manual Override
Push Style
(Poppet 2-Way Normally-Open Cartridge Style)
SOLENOID OPERATED VALVES
Torque 3-4 Nm
1-1/16"-12UN-2A
2
1
2
61
45
68
22.22
Hex.32
2
1
EP-12W-X-Y-Z-05
Coil EC-04W