G 1"
Torque 3-4 Nm
2
1
65
30
61
48
2
Hex.38
D.101.812
OPERATION
Y
TECHNICAL DATA
STRUCTURE
X
OPTIONS
Max.Operating pressure: 350
Rated flow: 150
Cavity-Tooling: 21E-2
Installation torque: 80-100
Weight: 0.35
Z
2A
2 Ports20 Watt. Coil
Non-adjustable
N
Rev.120913
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be ordered separately
Mounting Position:
unrestricted
0.15cc/minute
(3 drops/minute) max.at 350 bar
90 % of
nominal
Screw-out Knob Style
M
This design allows faster response times with very
small flow or even virtually zero flow.
Closing
Opening
24
20
16
12
8
4
16012080400
Pressure- P(bar)
Flow-Q(l/min)
Flow-Q(l/min)
Time (ms)
0
50
100
150
200
40 80
When de-energized, the valve acts as a check vlave,
to
120
.
When energized,the cartridge's poppet lifts to open
flow path. In this mode,flow
No Reverse Flow Energized
is severely restricted. if this path is
160
Normally-Closed
to
from
allowing flow fromto,while blocking flow fromto
01
(Poppet 2-Way Normally-Closed Cartridge Style With Extra Spring)
SOLENOID OPERATED VALVES
2
1
EP-21E-X-Y-Z-85
Coil EC-04W