EP-08W-X-Y-Z-85
D.101.802
18
Closing
Opening
TECHNICAL DATA
STRUCTURE
X
Max.Operating pressure: 350
Rated flow: 40
Cavity-Tooling: 08W-2
Installation torque: 39-51
Weight: 0.13
2A
2 Ports20 Watt. Coil
Rev.120913
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be ordered separately
Mounting Position:
unrestricted
0.15cc/minute
(3 drops/minute) max.at 350 bar
90 % of nominal
This design allows faster response times with very
small flow or even virtually zero flow.
Screw-out Knob Style
M
N
Non-adjustable
15
to
Z
12
9
6
No Reverse Flow Energized
is severely restricted. if this path is
OPTIONS
Normally-Closed
to
from
3
504030
flow path. In this mode,flow
When energized,the cartridge's poppet lifts to open
.
When de-energized, the valve acts as a check vlave,
OPERATION
Y
5040302010
200
150
100
50
0
Time (ms)
Flow-Q(l/min)
Flow-Q(l/min)
Pressure- P(bar)
0 10 20
allowing flow fromto,while blocking flow fromto
01
(Poppet 2-Way Normally-Closed Cartridge Style With Extra Spring)
SOLENOID OPERATED VALVES
Hex.24
3/4"-16UNF-2A
Torque 3-4 Nm
1
2
28
4
70
12.7
66
2
1
Coil EC-04W