Coil EC-04W
EP-19E-X-Y-Z-05
Hex.24
3/4"-16UNF-2A
Torque 3-4 Nm
2
1
66
70
1.4
15.87
28
D.101.200
No Reverse Flow Energized
TECHNICAL DATA
STRUCTURE
X
OPTIONS
Max.Operating pressure: 350
Rated flow: 40
Cavity-Tooling: 19E-2
Installation torque: 39-51
Weight: 0.13
Z
2A
2 Ports20 Watt. Coil
Non-adjustable
N
Rev.120707
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
Fluids-Temperatures: -40~120
Internal Leakage:
Filtration: 25 μm nominal or better
Minimun Voltage Required:
Coils must be ordered separately
Mounting Position:
unrestricted
0.15cc/minute
(3 drops/minute) max.at 350 ba
r
90 % of nominal
M
Screw-out Knob Style
01
Opening
Closing
12
10
8
6
4
2
50403020100
Pressure- P(bar)
Flow-Q(l/min)
Flow-Q(l/min)
Time (ms)
0
50
100
150
200
10 20 30 40 50
Y
OPERATION
Normally-Closed
t
o
(Poppet 2-Way Normally-Closed Cartridge Style)
SOLENOID OPERATED VALVES
2
1