TECHNICAL DATA
OPERATION
X
SPRINGS
OPTION
Y
Max. pressure: 240 bar
Rated flow: 80 l/min
Cavity-Tooling: 12W-4
Installation torque: 45-55 Nm
Weight: 0.25 kg
LOGIC ELEMENTS
Z
Non-adjustable
N
Cracking pressure
Rev.161019
B.704.303
Ordering Code:
70
7.0 bar
UNIT:mm
40
0
20
40 60
80
2
4
6
8
10
Output Flow vs. Orifice Dia.
with 7 bar
Orifice Diameter (mm)
Flow (l/min)
100
Standard Type
(Bypass/Restrictive, Priority Modulating Element)
LR-12W-X-Y-Z
2
1
3
4
P
2696
Hex.32
Torque 45-55 Nm
1-1/16"-12UN-2A
4
3
2
1
P