2
3
1
4
(Pilot )
(Pilot )
(Pilot )
(Pilot )
(2-Way, Pilot Shifted, Normally Closed, Proportional Throttle)
(Pilot )
Compensated
PILOT PRESSURE
10 bar
Ports 1 and 4 should be limited to 35 bar
TECHNICAL DATA
OPERATION
X
Max. pressure: 350 bar
Rated flow: 240 l/min
Cavity-Tooling: 24A-4
Installation torque: 465-500 Nm
1
(L Control)
Adjustable pilot
with LP-19A-30-140-N
Normally Closed
Rev.160318
B.610.141
Ordering Code:
UNIT:mm
Weight: 1.51 kg
2 3
350 bar
3
35
FLOW CONTROL VALVE
4C
4 Port,
socket screw.
to Operate 10 bar)
240 LPM
MAX. FLOW
B
Y
600
400
200
3020100
0 10 20
30
100
200
003003
200
100
3020100
35
600
400
200
3020100
0
100 200 300
200
400
35
(The adjustment range is 1.4~13 bar)
(Minimum Pilot Pressure
600
210 bar
(7 bar Standard Setting)
350
700
N
Self-compensated
Flow v.s Pilot Pressure
LPM
Non-adjustable
at Varying Pressures
Self-compensated
BAR
Self-compensated
Flow v.s Press. Differential
Flow v.s Pilot Pressure
Compensated
with LP-19A-30-140-N
Flow v.s Pilot Pressure
Z
17 bar Fully Open
70 bar
2
Flow to
L
350 bar
Flow to
2
3
Flow to 3
2
Leakproof hex.
LPM
BAR
BAR
LPM
35
Flow to
BAR
70 bar
16 bar
LPM
210 bar
LPM
14 bar
BAR
12 bar
10 bar
Pressure Range
Adjustable pilot
Pressure Range
(L Control)
1
1
1
Pressure Differential
1
3Flow to 2
OPTIONS
Flow v.s Pilot Pressure
MIN.
FP-24A-X-Y-Z
N Control
L Control
N=80.3
L=124
40
63.5
Pilot
Locating
Shoulder
Drain
Valve
M48x2
Valve
41.2 Hex.
(1 5/8 inch)
3
2
4
1