FD-16W-X-Y-Z-2080
B.602.124
50-165 LPM Ratio 20:80
TECHNICAL DATA
OPERATION
OPTION
Pressure min-max: 10-350
Rated Input Flow: 165
Cavity-Tooling: 16W-4
Installation torque: 60-70
Weight: 0.38
Z
Non-adjustable
N
Rev.150112
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
30
20
10
200
120
80
40
0
Pressure Drop- P (bar)
Flow-Q (l/min)
Fluids-Temperatures: -40~120
Flow Accuracy: 10% from 40-100%
Filtration: 25 μm nominal or better
Mounting Position:
unrestricted
of Max.Input flow
40
160
90
28 bar pressure drop at max.flow
4 Ports;Flow Divider
41
165
= 20:80 (Flow Ratio)
Port
90
= 20:80 (Flow Ratio)
(2)Should either or become blocked in flow division mode.
(3)NOTE:Flow combining is not permitted.
4
2
4
Y
NOMINAL CAPACITY
Other ratio options available;consult factory
30-90 LPM Ratio 20:80
2
Port
②:
X
(1)The FD16W-41 will divide input flow from to and ,
based on the ratio specified,regardless of operating
pressure.
3
Port
②:
Port
165
FLOW DIVIDER VALVES
3
2
4
Port
not used
25.42
27.00
1-5/16"-12UN-2A
28.60
Hex.38
Torque 60-70 Nm
3
Port not used
1
2
4
12.6100.5