FLOW DIVIDER/COMBINER VALVES
3
2
4
Port not used
B.601.112
TECHNICAL DATA
OPERATION
NOMINAL CAPACITY
OPTION
Y
Pressure min-max: 10-350
Rated Input Flow: 54
Cavity-Tooling: 10W-4
Installation torque: 35-45
Weight: 0.11
Z
Non-adjustable
N
Rev.140926
Ordering Code:
UNIT:mm
kg
Nm
l/min
bar
30
20
10
50
30
20
10
0
Pressure Drop- P (bar)
Flow-Q (l/min)
03
Fluids-Temperatures: -40~120
Flow Accuracy: 10% from 40-100%
Filtration: 25 μm nominal or better
Mounting Position:
unrestricted
of Max.Input flow
40
40
06
13
24
37
44
54
1.2- 3 LPM Ratio 50
:50
3- 6 LPM Ratio 50:50
6-13 LPM Ratio 50:50
10-24 LPM Ratio 50:50
15-37 LPM Ratio 50:50
18-44 LPM Ratio 50:50
2
3
2
22-54 LPM Ratio 50:50
Other ratio options available;consult factory
4
03
2
24
3
54
4
28 bar pressure drop at max.flow
Flow Divider/Combiner
60
40
4 Ports;
X
(2)The valve will combine input flow from both and to .
(3)Should either or become blocked in flow division mode.
(1)The FD10W-40 will divide input flow from to and ,
based on the ratio specified,regardless of operating pressure.
4
FD-10W-X-Y-Z
15.87
17.47
Torque 35-45 Nm
Hex.25.4
7/8"-14UNF-2A
19.05
4
1
2
Port not used
3
7.7
64.5