(Electro-Proportional, Normally Closed, Fast-acting)
Co
mmand Current, mA
Weight:(with Coil) 1.49 kg
(without Coil) 1.25 kg
FLOW CONTROL VALVE
Rev.170602
B.352.214
Ordering Code:
UNIT:mm
09
OPT
IONS
TECHNICAL DATA
M
ax.Operating pressure: 350
Rated flow:
320
C
avity-Tooling:
1
8A-2
Installation torque: 200-215 Nm
l/min
bar
Fluids-Temperatures: -40 to 120
Leakage at P of 140 bar
Coils must be ordered separately
50cc/minute maximum
NOMINAL CAPACITY
Z
P
(
Non-adjustable
350
Recommended PWM frequency
60-150 HZ, application dependent,
rated current at 10 bar pressure
Energized,Nose-in,Side-out Operation
X
Push Style
FLOW
N
② ①
drop - Pulse Width Modulated(PWM)
P:14 bar
Typical Metering Preformance
15
12
9
6
3
0
60 120 180 240
18
360
3200
0-320 LPM
2 Ports22 Watt. Coil
)
Manual Override
300
(24 V)
(12 V)
200
400 600
800 1000 1200
600
500
300
400
300200
100
0
50
100
150
200
P=bar
Flow-Q(l/min)
250
140 HZ typical
Typical hysteresis less than 4% of
19 mm tube
Normally-Closed,No Reverse Flow
Flow-Q(l/min)
Typical Pressure Drop
Y OPTIONS
(
① ②
)
2
1
PEV-18A-2D-X-Y-Z
Coil EC-19A
Locating
Shoulder
Torque 3-5 Nm
M48x2
2
46 Hex.
1
79.5 105
19