1
Flow Inlet
Bypass Flow
2
Priority Flow
3
Locating
Shoulder
L=83
K=90
TECHNICAL DATA
OPERATION
X
Priority Flow
(customer must specity flow)
Y
Max. pressure: 350 bar
Maximum Inlet Flow: 240 l/min
Cavity-Tooling: 17A-3
Installation torque: 200-215 Nm
Weight: 0.57 kg
FLOW CONTROL VALVE
3F
3 Port, Fixed Orifice,
Bypass/Restrictive
Rev.170112
B.341.103
Ordering Code:
0040
Example: 4.0 LPM
(Fixed orifice, bypass/restrictive, priority, flow control valve)
UNIT:mm
0300
Example: 30.0 LPM
Priority Flow Ranges: 0.8-95 l/min
Leakproof hex.
socket screw.
L
Z
OPTIONS
Handknob with
Lock Knob.
K
.Customer must specify a flow rating
.Pressure at the bypass port(port 2) may
exceed pressure at the priority port (port 3)
.Both priority and bypass flow are usable up to
the system operating pressure
.Bypass flow is not available until priority flow
requirements are satisfied
.Blocking priority flow will also block bypass flow
.Factory set flow ratings are within +/- 10% of the
requested setting
(Tuning Adjustment 25%
of customer specified flow)
(Tuning Adjustment 25%
of customer specified flow)
N
Non-adjustable
(Factory set at customer
specified flow)
Priority pressure
higher than bypass
Bypass pressure
higher than priority
with 80 inlet
with 240 inlet
with 80 inlet
with 160 inlet
with 240 inlet
Factory Set Point
Valve Set
@ 15 L/min.
Valve Set
@ 45 L/min.
0
0
75
60
45
Typical Performance
30
15
210
70
70
210
350
350
Priority Flow
Q=L/min
P=bar
0450
Example: 45.0 LPM
Example: 7.6 LPM
0076
2
3
1
FR-17A-X-Y-Z
2
3
1
46
Control Option:
Maximum extension
from locating shoulder.
(L Control shown)
31.7 Hex.
(1 1/4 inch)
M36x2
30
N=46