Pressure- P(bar)
160
Regulated Pressure
90
Flow-Q(l/min)
Capacity as a Restrictive Compensator
120 140
55
35
10
200
14
10040 60
3.5
7
20
80
Pressure (bar)
Flow-Q(l/min)
0306090120
60
120
180
30
150
PD-2A-X-Y-Z
12
3
(Direct Acting)
of the very low leakage at the reduced pressure
pressure drop to get bigger flow pass through.
TECHNICAL DATA
OPERATION
X
SPRINGS
Y
Max.Operating pressure: 350 bar
Rated flow: 80 l/min
Cavity-Tooling: 2A-3
Maximum Leakage (50 cc/min./70 bar)
according to the flow.
=L) kg
REDUCING VALVE
3J
ADJUSTMENT RANGES
Rev.191227
B.211.122
Ordering Code:
50-210 bar (70 bar Standard Setting)
A
B
20-105 bar (35 bar Standard Setting)
UNIT:mm
14-55 bar (28 bar Standard Setting)
D
E
7-28 bar (14 bar Standard Setting)
C
side of the circuit. The pressure at port
Z
socket screw.
Z
L
Installation torque: 60-70 Nm
Weight: 0.36 (
Cover.
S
3.5-14 bar (7 bar Standard Setting)
Leakproof hex.
OPTIONS
2
(46 cSt, 40 )
Stainless Steel
increase toward port
1
at the pressure setting of the spring, it will gradually
Tamper Resistant
will not stop
Without Relief function
Please pay attention when using this valve in a
dead-head application (no flow from port
1 to
port
2 ) because it is without relieving function. The
pressure may continue increase obviously because
When the pressure drop of LP-*-30 is 14 bar, the
orifice is not able to satisfy customer’s demand for
big flow. We suggest choosing PD-*-3J, which has
bigger orifice and is able to be adjusted to higher
4.0 Hex.
14.27 Hex. (9/16 inch)
Torque 9-10 Nm
Apply C6 (5JAA097)
Plastic tamper
resistant cover
from locating shoulder.
Locating
Shoulder
1.0"-14UNS-2A
(Z:L Control shown)
28.57 Hex.
2
1
(1-1/8 inch)
Pressure
Inlet
Reduced
Tank 3
Control Option:
Maximum extension
25
87 35.1