CK-23A-X-Y-Z
the pilot area to the vented spring chamber
socket screw.
Rev.151223
B.135.203
Flow-Q(l/min)
Typical Pressure Drop
Y=50
P=bar
0
80 160 240
10
20
320
TECHNICAL DATA
30
L
SPRINGS
Y
Cracking pressure
03
0.3 bar
(Vented Pilot-to-Open, Check Valve)
35
Y=20
3.5 bar
Full Pilot
every 4000 cycles.
Maximum Leakage (0.07 cc/min.)
10
1.0 bar
2.0 bar
5.0 bar
7.0 bar
50
70
20
UNIT:mm
Ordering Code:
N Non-adjustable
Pilot Ratio 3:14C
Z
CHECK VALVES
Weight: 0.68 kg
Installation torque: 200-215 Nm
Cavity-Tooling: 23A-4
Rated flow: 240 l/min
Max. pressure: 350 bar
OPTION
X
OPERATION
Approximately 0.07 cc of fluid will pass from
Leakproof hex.
Control Option:
Maximum extension
from locating shoulder.
(L Control shown)
Locating
Shoulder
Vent 4
1
Load
M36x2
Valve 2
3Pilot
31.7 Hex.
(1 1/4 inch)
46
70.8
81
2
3
1
4