CK-21A-X-Y-Z
(Vented Pilot-to-Open, Check Valve)
the pilot area to the vented spring chamber
TECHNICAL DATA
OPERATION
X
OPTION
Max. pressure: 350 bar
Rated flow: 60 l/min
Cavity-Tooling: 21A-4
Installation torque: 40-50 Nm
Weight: 0.18 kg
CHECK VALVES
Z
4C Pilot Ratio 3:1
Non-adjustableN
Rev.151228
B.135.201
Ordering Code:
UNIT:mm
0.3 bar
03
Cracking pressure
Y
SPRINGS
Flow-Q(l/min)
Pressure Differential vs. Flow
Y=50
P=bar
0
20
40
60
5
10
15
20
80
25
Y=20
20
70
50
7.0 bar
5.0 bar
2.0 bar
1.0 b
ar
10
L
Y=03
Maximum Leakage (0.07 cc/min.)
every 4000 cycles.
3.5 bar
35
Approximately 0.07 cc of fluid will pass from
Leakproof hex.
socket screw.
2
3
1
4
Locating
Shoulder
Control Option:
Maximum extension
from locating shoulder.
(L Control shown)
4Vent
Load 1
M20x1.5
Valve 2
3Pilot
22.2 Hex.
(7/8 inch)
35.1
53.3
63.5