(Vented Pilot-to-Open, Atmospherically Referenced)
the pilot area to the vented spring chamber
(7/16"-20UNF-2B)
TECHNICAL DATA
OPERATION
X
OPTION
Max. pressure: 350 bar
Rated flow: 240 l/min
Cavity-Tooling: 17A-3
Installation torque: 200-215 Nm
Weight: 0.6 kg
CHECK VALVES
Z
3C Pilot Ratio 3:1
Non-adjustable
N
Rev.151224
B.135.103
Ordering Code:
UNIT:mm
0.3 bar
03
Cracking pressure
Y
SPRINGS
Flow-Q(l/min)
S04
Y=50
P=bar
0
60 160
240
5
10
15
20
320
25
Y=20
20
70
50
7.0 bar
5.0 bar
2.0 bar
1.0 bar
10
Typical Pressure Drop
Maximum Leakage (0.07 cc/min.)
Full Pilot
every 4000 cycles.
3.5 bar
35
Approximately 0.07 cc of fluid will pass from
External SAE-4 Port
1
2
3
Locating
Shoulder
Pilot 3
Outlet 2
1Inlet
46
62.8 (Z=S04 OPTION)
71 (Z=N OPTION)
CK-17A-X-Y-Z
M36x2
31.7 Hex.
(1 1/4 inch)
30