(Vented Pilot-to-Open, Atmospherically Referenced)
Typical Pressure Drop
TECHNICAL DATA
OPERATION
X
OPTION
Max. pressure: 350 bar
Rated flow: 120 l/min
Cavity-Tooling: 2A-3
Installation torque: 60-70 Nm
Weight: 0.29 kg
CHECK VALVES
Z
3C Pilot Ratio 3:1
Non-adjustable
N
Rev.151224
B.135.102
Ordering Code:
UNIT:mm
0.3 bar
03
Cracking pressure
Y
SPRINGS
20
70
50
7.0 bar
5.0 bar
2.0 bar
1.0 bar
10
External SAE-4 Port
S04
Approximately 0.07 cc of fluid will pass from
every 4000 cycles.
3.5 bar
35
Y=50
the pilot area to the vented spring chamber
(7/16"-20UNF-2B)
Y=20
25
120
20
15
10
5
90
60
30
0
Maximum Leakage (0.07 cc/min.)
P=bar
Full Pilot
Flow-Q(l/min)
(1 1/8 inch)
25.8 Hex.
1.00-14UNS-2A
1
2
3
CK-2A-X-Y-Z
Locating
Shoulder
2
Pilot 3
Inlet
1
Outlet
25
59.3 (Z=N OPTION) 35.1
50.8 (Z=S04 OPTION)