CV-5A-X-Y-Z
Locating
Shoulder
Maximum Extension
from Locating Shoulder.
Out
(1 1/8 inch)
2
In
28.5 Hex.
1.00-14UNS-2A
1
17.5
41.1
(Free flow side to nose check valve)
0.15 bar
TECHNICAL DATA
OPERATION
X
SPRINGS
OPTION
Y
Max. pressure: 350 bar
Rated flow: 120 l/min
Cavity-Tooling: 5A-2
Installation torque: 60-70 Nm
Weight: 0.20 kg
CHECK VALVE
Z
21
2 to 1 (Free Flow)
Non-adjustable
N
Cracking pressure
Rev.120625
B.130.302
Ordering Code:
03
0.3 bar
10
1.0 bar
20
2.0 bar
35
3.5 bar
50
5.0 bar
70
7.0 bar
20
16
8
4
120
90
60
30
0
P=bar
Flow-Q(l/min)
Typical Pressure Drop
0.3 bar
2 bar
5 bar
UNIT:mm
12
015
1
2