Locating
Maximum extension
22.2 Hex.
(L Control shown)
Shoulder
Load
M20x1.5
from locating shoulder.
Pilot
(7/8" inch)
Control Option:
Turn screw clockwise
to reduce setting and
release load.
Valve
1
2
3
19
5135.1
Piloted Open
Free Flow
(Vented, Atmospherically Referenced, 280 Bar Maximum Setting)
Leakproof hex.
Flow-Q(l/min)
Pressure- P(bar)
0
10 20 30 40
10
20
30
40
50
TECHNICAL DATA
Max. Setting: 280 bar
Rated flow:
3
0 l/min
Cavity-Tooling: 11A-3
Installation torque: 40-50 Nm
Weight:
0
.16 (Z:L) kg
Pressure Setting:
COUNTERBALANCE VALVE
4.5 : 1 (with sealed pilot)
load induced pressure.
Rev.171027
B.124.201
Ordering Code:
UNIT:mm
3D
X
PILOT RATIO
70-280 bar (210 bar Standard Setting)
H
Y
SPRINGS
ADJUSTMENT RANGES(2.8 bar Cracking Pressure)
Setting should be 1.3 times maximum
C
Cover.
OPTIONS
Z
Tamper Resistant
socket screw.
L
Stainless Steel
Free Flow or Piloted Open
Pressure Drop
CA-11A-X-Y-Z30
2
3
1