Pressure- P(bar)
20
10
5
8060
25
15
to
Piloted Open
(Vented, Atmospherically Referenced, 350 Bar Maximum Setting)
0 20 40
Free Flow
to
Pressure Drop
3 : 1 (with sealed pilot)
Flow-Q(l/min)
TECHNICAL DATA
Max. Setting: 350 bar
Rated flow: 60 l/min
Cavity-Tooling: 10WB-3
Installation torque: 35-45 Nm
Weight: 0.22 (Z:L) kg
Pressure Setting:
C
Z
load induced pressure.
Rev.170511
B.124.106
Ordering Code:
UNIT:mm
3C
X
PILOT RATIO
20-160 bar (70 bar Standard Setting)
105-280 bar (210 bar Standard Setting)
I
H
Y
SPRINGS
COUNTERBALANCE VALVE
Cover.
OPTIONS
Setting should be 1.3 times maximum
Tamper Resistant
socket screw.
L
Stainless Steel
Leakproof
hex.
ADJUSTMENT RANGES(2 bar Cracking Pressure)
CA-10WB-X-Y-Z
from locating shoulder.release load.
7/8"-14UNF-2A
(L Control shown)
Turn screw clockwise
Locating
Shoulder
to reduce setting and
Control Option:
Maximum extension
25.4 Hex.
(1 inch)
3
2
1
19
59
52.5
2
3
1