Locating
Load
1
31.7 Hex.
Shoulder
Valve
2
(L Control shown)
Maximum extension
M36x2
(1 1/4 inch)
from locating shoulder.
Control Option:
Turn screw clockwise
to reduce setting and
release load.
Without
Pilot Assist
70
46
3
2
1
(Without Pilot Assist,3 Port Cavity)
Z
OPTIONS
Cover.
TECHNICAL DATA
PILOT RATIO
X
Max. Setting: 280 bar
Rated flow: 240 l/min
Cavity-Tooling: 17A-3
Installation torque: 200-215 Nm
Weight: 0.6 kg
Pressure Setting:
L
COUNTERBALANCE VALVE
23
Without Pilot Assist,
load induced pressure.
Rev.160225
B.122.103
Ordering Code:
UNIT:mm
Typical Relief Characteristics
300
250
200
150
100
50
240
180
120
60
0
Pressure- P(bar)
Flow-Q(l/min)
SPRINGS
Y
H
I
70 to 280 bar (210 bar Standard Setting)
ADJUSTMENT RANGES(2 bar Cracking Pressure)
25 to 105 bar (70 bar Standard Setting)
70 to 280 bar (210 bar Standard Setting)
A
B
SPECIAL PURPOSES(0.3 bar Cracking Pressure)
25 to 105 bar (70 bar Standard Setting)
8 to 25 bar (14 bar Standard Setting)
N
E
16 to 55 bar (25 bar Standard Setting)
C
Leakproof hex.
3 Port Cavity
Setting should be 1.3 times maximum
socket screw.
Stainless Steel
Tamper Resistant
CB-17A-X-Y-Z
3
30