Electronic
pressure measurement
WIKA data sheet PE 81.21
Page 1 of 7
Pressure transmitter with thin lm technology
For mobile hydraulic applications
Model MH-1
Description
Robust design
Extreme shock and vibration resistance, resistance to pressure
spikes (CDS system) and ingress protection greater than
IP68 make the model MH-1 pressure transmitter especially
qualied for the harsh operating conditions in mobile hydraulics.
Measuring ranges from 0 ... 60 to 0 ... 600 bar cover the
standard applications in mobile hydraulics completely.
Proven thin-lm sensor technology
The hermetically welded thin-lm measuring cell ensures a
high long-term leak tightness. The need for additional sealing
materials is dispensed with completely.
The thin-lm sensor is especially impressive in applications
with high dynamic loads. The thin-lm sensor of the MH-1 is
made from stainless steel and is manufactured using sputtering
technology which ensures a high long-term stability.
A special protection to prevent the escape of oil following
damage is oered by the recessing of the security sensor within
the process connection.
The design matched to mobile applications enables shock
loading up to 100 g and vibration up to 20 g.
Very good EMC characteristics in accordance with EN 61326
ensure reliable operation even under severe EMC conditions. In
addition, there is protection against load dump of up to 200 V.
High ingress protection
Even extreme temperature shocks do not aect the operational
safety. Especially for mobile applications, these pressure
transmitters oer a wide range of available ingress protections.
As well as the M12 x 1 circular connector with a screw-on lid, an
angular connector per DIN EN 175301-803, form C with IP65 is
also available.
For extreme applications, cable versions up to IP69K (steam
jet-proof) with pre-assembled, customer-specic connectors
are available.
Pressure transmitter, model MH-1
Applications
Mobile hydraulics
Machine building
General industrial applications
Special features
Measuring ranges from 0 ... 60 to 0 ... 600 bar
Output signals 4 ... 20 mA and DC 1 ... 5 V
Extremely shock and vibration resistant
Ingress protection IP65 to IP69K (steam jet-proof)
WIKA data sheet PE 81.21
08/2017
Page 2 of 7 WIKA data sheet PE 81.21 ∙ 08/2017
Measuring ranges
Gauge pressure
bar 0 ... 60 0 ... 100 0 ... 160 0 ... 250 0 ... 400 0 ... 600
psi 0 ... 1,000 0 ... 1,500 0 ... 2,000 0 ... 3,000 0 ... 5,000 0 ... 8,000
Other measuring ranges on request.
Overload safety: 2 times
Vacuum tightness: Yes
Output signals
Signal type Signal
Current (2-wire) 4 ... 20 mA
Voltage (3-wire) DC 1 ... 5 V
Other output signals on request.
Load
Current (2-wire): ≤ (power supply - 10 V) / 0.02 A
Voltage (3-wire): > 5 kΩ
Voltage supply
Power supply
Current (2-wire): DC 10 ... 30 V
Voltage (3-wire): DC 10 ... 30 V
Time response
Settling time: ≤ 5 ms
Reference conditions (per IEC 61298-1)
Temperature: 15 ... 25 °C (59 ... 77 °F)
Atmospheric pressure: 860 ... 1,060 mbar (12.5 ... 15.4 psi)
Humidity: 45 ... 75 % r. h.
Power supply: DC 24 V
Mounting position: Calibrated in vertical mounting position with process connection facing downwards.
Accuracy specications
Non-linearity (per IEC 61298-2): ≤ ±0.4 % of span BFSL
Accuracy ≤ 0.5 % of span BFSL
1)
Long-term stability (per DIN 16086:2006-01): ≤ 0.2 % of span/year
1) Including non-linearity, hysteresis, zero oset and end value deviation (corresponds to measured error per IEC 61298-2).
WIKA data sheet PE 81.21 ∙ 08/2017 Page 3 of 7
Operating conditions
Permissible temperature ranges
Medium: -40 ... +125 °C (-40 ... +257 °F)
Ambient: -30 ... +85 °C (-22 ... +185 °F), option: -40 ... +85 °C (-40 ... +185 °F)
Depending on the choice of sealing on the process connection, the electrical connection or cULus approval, the medium and
ambient temperatures may be limited (for restrictions see “Process connections,
sealings” and “Electrical connection”).
Storage and transport conditions
Storage temperature: -40 ... +85 °C
Climate classes
Storage: 1K4 (per EN 60721-3-1)
Transport: 2K3 (per EN 60721-3-2)
Operation: 4K4H (per EN 60721-3-4, without condensation or icing)
Vibration resistance: 20 g (IEC 60068-2-6)
Shock resistance: 500 g (IEC 60068-2-27)
Process connections
Standard Thread size
DIN 3852-E G ¼ A
M14 x 1.5
ANSI/ASME B 12.5 ¼ NPT
Others on request.
Page 4 of 7 WIKA data sheet PE 81.21 ∙ 08/2017
Electrical connections
Description Ingress protection
Circular connector M12 x 1, 4-pin IP67
Angular connector DIN 175301-803 C
Wire cross-section max. 0.75 mm
2
Cable diameter 4.5 ... 6 mm
IP65
Cable outlet (1.5 m, 3 m, 5 m)
Wire cross-section 3 x 0.75 mm² / AWG 20 with end splices
Cable diameter 5.9 mm (2-wire), 8.4 mm (3-wire)
IP69K
Other connections on request.
Connection diagrams
Circular connector M12 x 1 (4-pin)
2-wire 3-wire
U+ 1 1
U- 3 3
S+ - 4
Angular connector DIN 175301-803 C
2-wire 3-wire
U+ 1 1
U- 2 2
S+ - 3
Cable outlet
2-wire 3-wire
U+ brown black
U- red black
S+ - black
Electrical protective measures
Short-circuit resistance: S+ vs. U-
Reverse polarity protection: U+ vs. U-
Insulation voltage: DC 500 V
Materials
Wetted parts
Stainless steel
WIKA data sheet PE 81.21 ∙ 08/2017 Page 5 of 7
Approvals
Logo Description Country
EU declaration of conformity
EMC directive
Pressure equipment directive
RoHS directive
European Union
EAC
EMC directive
Pressure equipment directive
Eurasian Economic Community
GOST
Metrology, measurement technology
Russia
KazInMetr
Metrology, measurement technology
Kazakhstan
- MTSCHS
Permission for commissioning
Kazakhstan
BelGIM
Metrology, measurement technology
Belarus
- GPN
Fire safety certication
Belarus
UkrSEPRO
Metrology, measurement technology
Ukraine
Uzstandard
Metrology, measurement technology
Uzbekistan
- CPA
Metrology, measurement technology
China
- CRN
Safety (e.g. electr. safety, overpressure, ...)
Canada
Manufacturer’s information and certicates
Logo Description
- China RoHS conformity
- MTTF > 100 years
Approvals and certicates, see website
Page 6 of 7 WIKA data sheet PE 81.21 ∙ 08/2017
with angular connector
DIN 175301-803 A
with M12 x 1 circular connector with cable outlet
G ¼ A DIN 3852-E
(overload safety 600 bar)
¼ NPT M14 x 1.5 DIN 3852-E
(overload safety 600 bar)
Dimensions in mm (in)
Weight approx. 0.2 kg
Weight approx. 0.2 kg Weight approx. 0.2 kg
Pressure port 3.5 mm
For information on tapped holes and welding sockets, see Technical information IN 00.14 at www.wika.com.
WIKA Alexander Wiegand SE & Co. KG
Alexander-Wiegand-Straße 30
63911 Klingenberg/Germany
Tel. +49 9372 132-0
Fax +49 9372 132-406
info@wika.de
www.wika.de
© 09/1998 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modications to the specications and materials.
08/2017 EN
Page 7 of 7 WIKA data sheet PE 81.21 ∙ 08/2017
Accessories and spare parts
Mating connector
Description Order number
without cable 2 m (6 ft) cable 5 m (16 ft) cable 2 m (6 ft) cable,
shielded
Angular connector DIN EN 175301-803 C 1439081 11225823 11250194 -
Circular connector M12 x 1 (4-pin)
straight - 11250780 11250259 14056584
angled - 11250798 11250232 -
Sealings for mating connectors
Mating connector Order number
Blue (WIKA) Brown (neutral)
Angular connector DIN EN 175301-803 C 11169479 11437881
Sealings for process connection
Thread size Order number
NBR FKM FPM
G ¼ A 1537857 1576534 1576534
M14 x 1.5 1537857 1576534 -
Ordering information
Model / Measuring range / Output signal / Process connection / Sealing / Electrical connection / Ambient temperature range /