2 / 9
030110_EPDRD3_04_e | ValveTech
Hydraulic
Operating pressure max.: port 2 (P): 315 bar, with aluminium manifolds: 210 bar
port 1 (A): 45 bar, pressure port 3 (T) < pressure port 1 (A)
Flow rate: 4 l/min
Pressure setting range: see type code
Flow direction: see symbol
Hydraulic uid: mineral oil according to DIN 51524, other hydraulic
uids upon request
Viscosity range: 10 - 350 cSt
Filtration: oil cleanliness according to ISO 4406 (1999)
18/16/13, lter with β 5(c) > 200
Repeatability: < 3 % with optimized PWM-signal*
Hysteresis: < 5 % with optimized PWM-signal*
* at 20 % to 100 % of the nominal valve current.
Technical Data
Mechanic
Design: EEPDRD slip-in valve, EPDRDR in in-line body,
EPDRDA in mounting plate NG 4 or NG 6,
direct operated
Size: 04
Fluid temperature: -25 ° C to +70 ° C
Ambient temperature: -25 ° C to +50 ° C
Storage temperature: -30 ° C to +60 ° C (non-condensing)
Installation position: any, preferably horizontal
Maximum acceleration: 5 g, crossways
Weight: EEPDRD3-04: 0,7 kg, EPDRDR3-04: 0,96 kg,
DEPDRDR3-04: 1,86 kg, EPDRDA3-04/04: 0,92 kg,
EPDRDA3-04/06: 0,98 kg, DEPDRDA3-04/06: 1,82 kg
Material: valve parts: steel, in-line body and mounting plate:
aluminium; seals: NBR, optional Viton
Surface protection: solenoid: zinc coated steel
in-line body and mounting plate: anodized aluminium
Electric
Nominal voltage: 12 V DC, 24 V DC
Nominal valve current: 1,7 A (12 V), 0,7 A (24 V)
Nominal resistance (R20): 4 Ω (12 V), 25 Ω (24 V)
Power consumption: 16 W at nominal valve current
Shifting time: 100 % ED
Control command: PWM-signal
PWM-frequency: typically 140 Hz (depending on application)
Protection class: IP65 with correctly mounted and locked mating connector
Electric termination: Electric plug according to DIN EN 175301-803 shape A,
AMP Junior Timer, unterminated wire
Electronic controllers: see chapter 6 “electronics and sensors” as well as our
online catalogue at www.weber-hydraulik.com
Proportional pressure control valve
NOTE
The pressure on port 3 (T) adds directly to the set pressure. The total pressure of
ports A and T must not exceed the maximum operating pressure.