2 / 6
020130_EPDBD_03_e | ValveTech
Electric
Nominal voltage: 12 V DC, 24 V DC
Nominal valve current: 1,2 A (12 V), 0,63 A (24 V)
Nominal resistance (R20): 6 Ω (12 V), 24 Ω (24 V)
Power consumption: 9,6 W at nominal valve current
Shifting time: 100 % ED
Control command: PWM-signal
PWM-frequency: typically 140 Hz (depending on application)
Protection class: IP65 with correctly mounted and locked mating con-
nector
Electric termination: Electric plug according to DIN EN 175301-803 (formerly
DIN 43650) shape B, unterminated wire
Electronic controllers: see chapter 6 "electronics and sensors" as well as our
online catalogue at www.weber-hydraulik.com.
Mechanic
Design : EEPDBD slip-in valve, EPDBDR in in-line body,
direct operated by solenoid
Size: 03
Fluid temperature: -20 ° C to +65 ° C
Ambient temperature: -20 ° C to +50 ° C
Storage temperature: -30 ° C to +60 ° C (non-condensing)
Installation position: any, preferably with solenoid facing down
Weight: EEPDBD 03: 0,24 kg
EPDBDR 03: 0,34 kg
Material: valve parts: steel, in-line body: aluminium
seals: NBR, Viton optional
Surface protection: exterior parts: zinc coated steel, partially burnished
in-line body: anodized aluminium
Hydraulic
Operating pressure max.: 250 bar (dynamic)
315 bar (with free return ow in port 2)
with aluminium in-line body max. 250 bar
Flow rate: 2,6 l/min at Δp according to pressure drop diagrams
Pressure setting range: see type code
Flow direction: 1 (P) to 2 (T) (2 to 1 not allowed)
Hydraulic uid: mineral oil according to DIN 51524, other hydraulic
uids upon request
Viscosity range: 10 - 350 cSt
Filtration: oil cleanliness according to ISO 4406 (1999)
18/16/13, lter with β 5(c) > 200
Repeatability: < 3 % with optimized PMW-signal*
Hysteresis: < 5 % with optimized PMW-signal*
* at 20 % to 100 % of the nominal valve current and approximately 10 to 63 cSt
Technical data
NOTE
The pressure on port 2 (T) adds directly to the set pressure. The total pressure of
ports 1 (P) and 2 (T) must not exceed the maximum operating pressure.
Proportional pressure relief valve