D1WWEG01E
87
NOTE - For dierent working conditions please contact Sales Dept.
PORTS THREAD
ALL PORTS BSP UN-UNF
DFE10 G 1/2 7/8-14 (SAE 10)
PILOT PORTS
L G 1/4 9/16-18 (SAE 6)
This catalogue shows technical specications and diagrams measured with mineral oil of 46 mm
2
/s (46 cSt) viscosity at 40°C -
(104°F) temperature.
DFE102
Solenoid control monoblock diverter valves
WORKING CONDITIONS
N. of available ways 3 - 6
Max. ow rating
90 l/min
(23.7 US gpm)
Max. pressure
without drain
200 bar
(2900 psi)
with drain
315 bar
(4600 psi)
Available supply voltage VDC see reference page 94
Nominal power 60 W
Internal leakage A(B)T
∆p = 100 bar
(1450 psi) 10 cm
3
/min (0.61 in
3
/min)
Fluid Mineral based oil
Fluid temperature
with NBR (BUNA-N) seals
from -20°C to 80°C
(from -4°F to 176°F)
with FPM (VITON) seals
from -20°C to 100°C
(from -4°F to 212°F)
Viscosity
operating range
from 15 to 75 mm
2
/s (from 15 to 75 cSt)
min.
12 mm
2
/s (12 cSt)
max.
400 mm
2
/s (400 cSt)
Max. level of contamination
20/18/15 - ISO 4406 -
NAS 1638 - class 9
Ambient temperature for
working conditions
from -20°C to 50°C
(from -4°F to 122°F)
_________________________________________________________________________________________
Available threads
3 - 6 ways conguration
Galvanized body
88
DFE102
D1WWEG01E
(psi)
0
1000
2000
3000
4000
5000
22.5
7.5 15
(US gpm)
0
0 22.5 45 67.5 90
(l/min)
(bar)
0
100
200
300
400
3 ways
Dimensional data - hydraulic circuit - performance data
_____________________________________
It's possible to obtain 2 ways diverter valve plugging port
Solenoid control monoblock diverter valves
P A(B)
(l/min)
(bar)
0
0 20 40 60 80
5
10
15
20
DFE052/2
(l/min)
(bar)
0
0 20 40 60 80
5
10
15
20
A(B)
A(B)
B
A
DFE052/3
DFE10/3
DFE20/3
(bar)
0
5
10
15
20
(l/min)
0 30 60 90 120
A(B)
(bar)
0
5
10
15
20
(l/min)
0 45 90 135 180
(psi)
(US gpm)
0
50
100
150
200
250
0 15105 20
(psi)
(US gpm)
0
50
100
150
200
250
0 15105 20
(psi)
(US gpm)
0
50
100
150
200
250
0 22.5157.5 30
(psi)
(US gpm)
0
50
100
150
200
250
0 33.7522.511.5 45
2 vie
3 VIE
6 ways
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
EF
CD
A B
GH
8 VIE
12 VIE
Flow Flow
Pressure
Pressure
Minimum dynamic conditions
(Supply = Vn-10%, coil at 70 °C -
158 °F)
With drain
Without drain
Pressure drop versus ow
spool
Emergency
manual override
AB
P
46.5
1.83
23.2
0.93
Ø 63
Ø 2.48
109
4.29
85.4
3.36
10.2
0.40
32.5
1.28
8
0.315
36
1.42
18
0.71
65
2.56
201.5
7.93
74
2.91
50
1.97
25
0.98
12
0.47
B A
Ø 8.3
Ø 0.327
n.3 holes
89
DFE102
D1WWEG01E
(psi)
0
1000
2000
3000
4000
5000
22.5
7.5 15
(US gpm)
0
0 22.5 45 67.5 90
(l/min)
(bar)
0
100
200
300
400
_____________________________________
Dimensional data - hydraulic circuit - performance data
6 ways
Solenoid control monoblock diverter valves
A(B)
A(B)
B
A
DFE052/6
DFE10/6
DFE20/6
(l/min)
(bar)
0
0 20 40 60 80
5
10
15
20
(l/min)
(bar)
0
0 30 60 90 120
5
10
15
20
(bar)
0
5
10
15
20
(l/min)
0 45 90 135 180
(psi)
(US gpm)
0
50
100
150
200
250
0 33.7522.511.5 45
(psi)
(US gpm)
0
50
100
150
200
250
0 15105 20
(psi)
(US gpm)
0
50
100
150
200
250
0 22.5157.5 30
A C(E)
2 vie
3 VIE
6 ways
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
EF
CD
A B
GH
8 VIE
12 VIE
Flow Flow
Pressure
Pressure
Minimum dynamic conditions
(Supply = Vn-10%, coil at 70 °C -
158 °F)
With drain
Without drain
Pressure drop versus ow
spool
Emergency
manual override
109
4.29
228.4
8.99
7
0.276
43
1.69
11.8
000
32.5
1.30
Ø 63
Ø 2.48
65
2.56
56.2
000
34.7
1.37
112.4
4.43
62
2.44
23
0.91
88.5
3.48
B
D
F
A
C
E
E
A
B
F
Ø 8.3
Ø 0.327
36
000
n.2 holes
90
DFE102
D1WWEG01E
Part ordering codes
______________________________________________________________________________________
Solenoid control monoblock diverter valves
Bellow
1 = without bellow
2 = with bellow
Coil
1 = without coil
2 = with coil
Coil voltage
Connection*
0 = ISO (Std)
2 = AMP-JPT
3 = Deutsch DT06
4 = Deutsch DT04-2P Male
5 = Deutsch DT04-4P Female
6 = Metri-Pack Female
7 = Metri-Pack Male
8 = WeatherPack Male
9 = WeatherPack Female
(
*) - For connector options see
coils table on page 94
Lenght cables
(only if it's present)
Lenght is in mm
... 2 0 (300) 2 - 12VDC - ...
Example:
DFE102/3 A 18 ES - W 2 0 2 - 12VDC - ... - CRZ
3 6
41 32
For description composition
see the text below
54
Galvanized body
5
3
4
4
2
3 ways
6 ways
8
7
1
91
DFE102
D1WWEG01E
1 Body kit*
TYPE CODE DESCRIPTION
DFE102/3 3CO2241321Z 3 ways body kit
DFE102/6 3CO2242322Z 6 ways body kit
2 Spools page 92
TYPE CODE DESCRIPTION
For DFE102/3:
A 3CAS110342 Flow in A in neutral.
Ports connected in transit position
B 3CAS110442 Flow in A in neutral.
Ports closed in transit position
D 3CAS110541 Closed ports in neutral and
connected in transit position
For DFE102/6:
A 3CAS110642 Flow in E and F. C and D closed in pos. 1
Ports connected in transit position
B 3CAS110742 Flow in E and F. C and D closed in pos. 1
Ports closed in transit position
H 3CAS110843 D‹–›C in pos. 1, F‹–›E in pos. 2
Ports closed in transit position
3 Positioner kit page 93
TYPE CODE DESCRIPTION
18...W 5TAP011 Spring return in pos. 1
18...Y 5GIU017* Spring return in pos. 1, with G1/4 drain port
(
*) - Codes are referred to BSP thread
4 Solenoid kit page 93
TYPE CODE DESCRIPTION
ES 5SOL519004-C Tube assembly without protective bellow
ES 5SOL519004A-C Tube assembly with protective bellow
- 4ACC519-C Optional protective bellow for tube aasembly
5 Coil
For list of available coils see pages 94
6 Body threading
Specify threading always when it is dierent from BSP standard
7 Port plugs*
It's possible to obtain 2 ways diverter valve plugging port of DFE102/3
CODE DESCRIPTION
3XTAP727180 G1/2 plug
8 Accessories
For list of available connectors see pages 94
8
7
______________________________________________________________________________________
Part ordering codes
Solenoid control monoblock diverter valves
92
DFE102
D1WWEG01E
Solenoid control monoblock diverter valves
Spool circuits
______________________________________________________________________________________________
Type A
Ports connected
in transit position
Type A
Flow in E and F. C and D closed in pos. 1
Ports connected in transit position
Type B
Ports closed
in transit position
Type B
Flow in E and F. C and D closed in pos. 1
Ports closed in transit position
Type D
Closed ports in neutral and
connected in transit position
Type H
D‹–›C in pos. 1, F‹–›E in pos. 2
Ports closed in transit position
3 ways
6 ways
1 2
2
cass A 2 vie
1 2
2
2
2
2
2
2
CASS. A 3 VIE
1
CASS A 6 ways
CASS B 6 ways
1
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
1
CE
BA
DF
CASS H 6 ways
1
CE
BA
DF
1
CASS. D 3 VIE
B
P
A
1
CASS. B 3 VIE
B
P
A
1
cass B 2 vie
A
P
CASS. B 12 VIE
21
EF
CD
A B
GH
0
CASS. B 8 VIE
CASS. I 8 VIE
21
EF
CD
A B
GH
0
CASS. A 8 VIE
21
EF
CD
A B
GH
0
1 2
2
cass A 2 vie
1 2
2
2
2
2
2
2
CASS. A 3 VIE
1
CASS A 6 ways
CASS B 6 ways
1
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
1
CE
BA
DF
CASS H 6 ways
1
CE
BA
DF
1
CASS. D 3 VIE
B
P
A
1
CASS. B 3 VIE
B
P
A
1
cass B 2 vie
A
P
CASS. B 12 VIE
21
EF
CD
A B
GH
0
CASS. B 8 VIE
CASS. I 8 VIE
21
EF
CD
A B
GH
0
CASS. A 8 VIE
21
EF
CD
A B
GH
0
1 2
2
cass A 2 vie
1 2
2
2
2
2
2
2
CASS. A 3 VIE
1
CASS A 6 ways
CASS B 6 ways
1
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
1
CE
BA
DF
CASS H 6 ways
1
CE
BA
DF
1
CASS. D 3 VIE
B
P
A
1
CASS. B 3 VIE
B
P
A
1
cass B 2 vie
A
P
CASS. B 12 VIE
21
EF
CD
A B
GH
0
CASS. B 8 VIE
CASS. I 8 VIE
21
EF
CD
A B
GH
0
CASS. A 8 VIE
21
EF
CD
A B
GH
0
1 2
2
cass A 2 vie
1 2
2
2
2
2
2
2
CASS. A 3 VIE
1
CASS A 6 ways
CASS B 6 ways
1
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
1
CE
BA
DF
CASS H 6 ways
1
CE
BA
DF
1
CASS. D 3 VIE
B
P
A
1
CASS. B 3 VIE
B
P
A
1
cass B 2 vie
A
P
CASS. B 12 VIE
21
EF
CD
A B
GH
0
CASS. B 8 VIE
CASS. I 8 VIE
21
EF
CD
A B
GH
0
CASS. A 8 VIE
21
EF
CD
A B
GH
0
1 2
2
cass A 2 vie
1 2
2
2
2
2
2
2
CASS. A 3 VIE
1
CASS A 6 ways
CASS B 6 ways
1
A
P
B
P
A
CE
BA
DF
A2
B2
C2
D2
A3
B3
C3
D3
A1
B1
C1
D1
1
CE
BA
DF
CASS H 6 ways
1
CE
BA
DF
1
CASS. D 3 VIE
B
P
A
1
CASS. B 3 VIE
B
P
A
1
cass B 2 vie
A
P
CASS. B 12 VIE
21
EF
CD
A B
GH
0
CASS. B 8 VIE
CASS. I 8 VIE
21
EF
CD
A B
GH
0
CASS. A 8 VIE
21
EF
CD
A B
GH
0
2
1
B
P
A
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
Spool stroke
Position 2: - 4.6 mm (-
0.18 in)
93
DFE102
D1WWEG01E
ES tube assembly kit
Y = wrench 27 - 24 Nm (17.7 lbft)
Z = 24 Nm (17.7 lbft)
Wrenches and tightening torque
With spring return in position 1
Type 18W
With plug
Type 18Y
With G1/4 drain port
Z = wrench 32 - 42 Nm (31 lbft)
Wrenches and tightening torque
Tipo 18W
Tipo 8
1
0
Tipo 17A
2
L
1
Tipo 18Y
2
1
Tipo 18PNCWP
2
0
1
V
Tipo 18IB1N
Tipo 18IB1
DF5
2
0
1
2
0
1
V
Tipo 18W
Tipo 8
1
0
Tipo 17A
2
L
1
Tipo 18Y
2
1
Tipo 18PNCWP
2
0
1
V
Tipo 18IB1N
Tipo 18IB1
DF5
2
0
1
2
0
1
V
Solenoid control monoblock diverter valves
_______________________________________________________________________________________________
Positioner kit
_________________________________________________________________________________________________
Solenoid kit
8.7
0.343
Z
22.5
0.89
G1/4
Z
L
M27x1.5
Ø 31
Ø 1.22
Z
Y
(127) with protective bellow
(5.00)
112
4.41
40.5
1.59
11
0.43
Push for manual
override
94
DFE102
D1WWEG01E
Coils and accessories
____________________________________________________________________________________
Features
Nominal voltage tolerance : ±10%
Nominal power ............... : 60 W - 12/24/28 VDC
Nominal current ............. : 5 A @ 12 VDC / 2.5 A @ 24 VDC / 2.14 A @ 28 VDC
Insulation ...................... : Class H (180°C)
Weather protection ......... : IP65 - ISO4400 / IP69K - Deutsch DT
Insertion ....................... : 100%
ISO4400 connector
89
3.50
75
2.95
75
2.95
Ø 63
Ø 2.48
31.5
1.24
88.1
3.47
75
2.95
Ø 63
Ø 2.48
31.5
1.24
DEUTSCH DT04 connector
(Parallel type)
Flying leads with
DEUTSCH DT04 connector
75
2.95
300
11.81
31.5
1.24
75
2.95
Ø 63
Ø 2.48
Flying leads
75
2.95
31.5
1.24
75
2.95
Ø 63
Ø 2.48
100
3.94
218.5
8.60
Ordering codes
Type
Voltage Connector types
ISO4400 Deutsch DT AMP JPT
Packard
Weatherpack
Packard
Metri-pack
Flying leads
without connector
D19C
12 VDC 4SOL519112-C
4SOL519402-C
(6)
4SOL519413-C
(2)
- - - 4SOL519113-C
24 VDC 4SOL519124-C
4SOL519404-C
(6)
4SOL519425-C
(2)
- - - -
28 VDC - 4SOL519128-C
(6-3)
- - - -
Mating connectors
4CN1009995 5CON140031 - - - -
Notes: (
1
) supply with AC and use only with rectier connector - (
2
) with ying leads - (
3
) with bidirectional diode - (
4
) with unidirectional diode
(
5
) integrated perpendicular type - (
6
) integrated parallel type