DIVISION
33
DIVISION
D1WWEO01A
DIVISION
Body Valves
Type VEP
Maximum ow
Maximum
pressure
Application range
with
standard springs
“Ap” (VMP)*
Application range with
standard springs “Bp”
(VDS)
Weight
line l/min US gpm bar psi
kg lb
VEP 38
Ap line
Bp line
U line
10
25
30
2.6
6.6
8
250
aluminium
body
350
steel
body
3600
alum.
body
5100
steel
body
50÷220 bar
- 725÷3200 psi
(test setting 180 bar
- 2600 psi 5 l/min.
- 1.32 US gpm)
180÷350 bar
- 2600÷5100 psi
(test setting 280 bar
- 4050 psi 5 l/min.
- 1.32 US gpm)
5÷40 bar - 72.5÷580 psi
(test setting 30 bar - 435 psi
at 5 l/min. - 1.32 US gpm)
20÷80 bar - 290÷1150 psi
(test setting 60 bar - 870 psi
at 5 l/min. - 1.32 US gpm)
1,20 2.64
aluminium
2,63 5.80
steel
VEP 12
Ap line
Bp line
U line
20
45
55
5.3
12
14.5
5÷80 bar - 72.5÷1150 psi
(test setting 40 bar - 580 psi
at 5 l/min. - 1.32 US gpm)
2,05 4.52
aluminium
4,50 9.92
steel
VEP 34
Ap line
Bp line
U line
30
80
100
8
21
26
10÷50 bar - 145÷725 psi
(test setting 30 bar - 435 psi
at 5 l/min. - 1.32 US gpm)
10÷80 bar - 145÷1150 psi
(test setting 50 bar - 725 psi
at 5 l/min. - 1.32 US gpm)
50÷110 bar - 725÷1600 psi
(test setting 80 bar -1150 psi
at 5 l/min. - 1.32 US gpm)
3,77 8.31
aluminium
9,37 20.66
steel
VEP 100
Ap
line
Bp line
U line
50
150
180
13
40
48
5÷40 bar - 72.5÷580 psi
(test setting 30 bar - 435 psi
at 5 l/min. -1.32 US gpm)
20÷80 bar - 290÷1150 psi
(test setting 60 bar - 870 psi
at 5 l/min. -1.32 US gpm)
50÷220 bar - 725÷3200 psi
(test setting 160 bar - 2300
psi at 5 l/min. - 1.32 US
gpm)
5,85 12.90
aluminium
13,50 29.76
steel
VEP 114
Ap
line
Bp line
U line
80
200
250
2
53
66
8,40 18.52
aluminium
19,50 42.99
steel
*To perform setting of the valve see the pressure drop/ow diagram.
HIGH/LOW PRESSURE
CUT-OUT VALVES
Type VEP
Operation
Recommended for systems powered by two pumps where double speed (fast-slow
sequence) is made available. Fast speed is obtained by summing up both pumps
capacity up to the setting value of the VDS valve. Slow speed according to the
small pump is obtained by later discharge of the bigger pump. Working pressure
during slow speed is controlled bu the VMP valve.
Performance
34
DIVISION
D1WWEO01A
Dimensions and hydraulic circuit
Rating diagrams
Order code
DIVISION
Section
0 2 4 6 8
(US gpm)
0 2 4 6 8
(US gpm)
0
4000
5000
3000
2000
1000
0
100
125
25
50
75
(psi)
(psi)
Pressure drop diagram
VEP 38 / - . - S /  
Adjustment
AP
(see page 80)
S
V
W
Body material
_
ac
Aluminium
Steel
Pressure setting AP
TS)
TR)
50÷220
180÷350
Pressure settings BP
TB)
TV)
5÷40
20÷80
bar
bar
bar
(screw)
(handknob)
(copped adjustment)
bar
Type VEP 38
High-low pressure cut-out valve
Adjustment diagram
(725÷3200 psi)
(2600÷5100 psi)
1.57
0.24
0.24
3.07
3.54
6.22
3.85
2.36
0.67
1.10
1.14 1.30
0.79
0.240.24 1.10
(72.5÷580 psi)
(290÷1150 psi)
0.79
Ø 0.25
DIVISION
35
DIVISION
D1WWEO01A
DIVISION
Rating diagrams
Order code
Dimensions and hydraulic circuit
Section
0 4 8 12 16
(US gpm)
0 4 8 12 16
(US gpm)
0
4000
5000
3000
2000
1000
(psi)
0
100
125
25
50
75
(psi)
Pressure drop diagram
VEP 12 / - . - S /  
Adjustment
AP
(see page 80)
S
V
W
Body material
_
a c
Aluminium
Steel
Pressure setting AP
T S )
T R )
50÷220
180÷350
Pressure settings BP
T V ) 5÷80
bar
bar
(screw)
(handknob)
(copped adjustment)
bar
Type VEP 12
Adjustment diagram
(725÷3200 psi)
(2600÷5100 psi)
(72.5÷1150 psi)
3.46
7.36
4.72
2.64
1.42
0.75
1.97
0.24
0.24
3.94
1.57
0.98
1.42
1.50 0.240.24
0.98
Ø 0.25
High-low pressure cut-out valve
36
DIVISION
D1WWEO01A
Dimensions and hydraulic circuit
Rating diagrams
Order code
DIVISION
Section
0 5 10 2015 25
(US gpm)
0 4 8 12 16
(US gpm)
0
4000
5000
3000
2000
1000
(psi)
0
100
125
25
50
75
(psi)
Pressure drop diagram
VEP 34 / - . - S /  
Adjustment
AP
(see page 80)
S
V
W
Body material
_
ac
Aluminium
Steel
Pressure settings
AP
TS)
TR)
50÷220
180÷350
Pressure settings BP
TB)
TV)
TS)
10÷50
10÷80
50÷110
bar
bar
barbar
bar
bar
(screw)
(handknob)
(copped adjustment)
Type VEP 34
Adjustment diagram
(725÷3200 psi)
(2600÷5100 psi)
(145÷725 psi)
(145÷1150 psi)
(725÷1600 psi)
4.49
8.92
5.90
1.571.18
3.01
2.36
0.310.31
0.31
0.31
1.73
1.57 2.05 1.10
5.11
1.18
Ø 0.33
High-low pressure cut-out valve
DIVISION
37
DIVISION
D1WWEO01A
DIVISION
Rating diagrams
Order code
Dimensions and hydraulic circuit
Pressure drop diagram
VEP 100 / - . - S /  
Adjustment
AP
(see page 80)
S
V
W
Body material
_
ac
Aluminium
Steel
Pressure settings AP
TS)
TR)
50÷220
180÷350
Pressure settings BP
TB)
TV)
TS)
5÷40
20÷80
50÷220
bar
barbar
bar
bar
(screw)
(handknob)
(copped adjustment)
Type VEP 100
Adjustment diagram
(290÷1150 psi)
(725÷3200 psi)
0.39
2.75
(725÷3200 psi)
(2600÷5100 psi)
1.97
0.39
0.39
0.39
5.11
5.90
10.57
7.09
1.18
2.75
3.48
2.28 2.36 1.26
(72.5÷580 psi)
Section
1.38
Ø 0.33
High-low pressure cut-out valve
38
DIVISION
D1WWEO01A
Dimensions and hydraulic circuit
Rating diagrams
Order code
DIVISION
0 5 10 2015 25
(US gpm)
0
4000
5000
3000
2000
1000
(psi)
0
100
125
25
50
75
(psi)
0 10 20 30 40 50 60 70
(US gpm)
Pressure drop diagram
VEP 114 / - . - S /  
Adjustment
AP
(see page 80)
S
V
W
Body material
_
ac
Aluminium
Steel
Pressure settings AP
TS)
TR)
50÷220
180÷350
Pressure settings BP
TB)
TV)
5÷40
20÷80
TS) 50÷220
bar
bar
bar
bar
bar
(screw)
(handknob)
(copped adjustment)
Type VEP 114
Adjustment diagram
(290÷1150 psi)
(725÷3200 psi)
(725÷3200 psi)
(2600÷5100 psi)
(72.5÷580 psi)
7.09
11.36
7.87
3.15
1.57
3.15
6.30
0.39
0.39
0.390.39
2.36
3.48
2.34 2.72 1.42
Section
1.57
Ø 0.33
High-low pressure cut-out valve