VIVOIL OLEODINAMICA VIVOLO
MIA - FD series
Manifold
instantaneous
auto-coMpensating
flow
divider
Flow Divider
ENGLISH
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
3
www.vivoil.com - English
Summary
General description 4
t
echnical information 5
p
recision 5
dependence of the error trend from temperature/viscosity 6
flow division precision definition 6
G
eneral information about how the flow divider works 7
mia-fd flow divider 7
flow division modality 8
flow combininG modality 8
cetop connection interface use on the flow divider staGes: 8
cetop interface on the flow divider staGes: 9
G
eneral instruction 10
flow rate definition 10
inlet number definition 10
installation 10
start up 11
use 11
maintenance 11
mva - standard version 12
exploded view with couplinG torque values 13
mve - command interface (
up to 50l/min) version 14
exploded view with couplinG torque values 15
v
alve characteristics 16
pressure control valve (50 l/min) 16
flow control valve (50 l/min) 16
h
ydraulic scheme examples 17
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
4
www.vivoil.com - English
General deScription
MIA-FD is the acronym for Manifold Instantaneous Auto-compensating Flow Divider. The VIVOIL MIA-FD ow divider is the
answer to the market request for continuous improvement of:
• Precision: All components has been re-engineered to allow for a tolerance constructive reduction and to reach a hi-
gher uniformity between elements. In addition we have included an internal auto-compensating system that removes
the dependency from the pressure dience between elements.
• Modular: each element is a single independent unit
• Congurable: each element can have added valves and other modular elements with CETOP NG6 , ISO 4401-03-02-0-
05.
• Expandable: the system can be improved by adding new divider elements on to an existing ow divider.
• Simple: the completed ow divider is a real compact manifold system and is easy to install.
The MIA-FD FLOW DIVIDER is not only a simple ow divider and combiner, but it is a system to distribute and feed with
constant and independent ow rates for the various circuit branches. The open architecture of the MIA-FD has been deve-
loped to be integrated into dierent functionality that will follow the customers requirements.
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
Error < 0,8%
Error < 1,2%
Error < 1,6%
5
www.vivoil.com - English
technical information
Attenction:
Please carefully read the following instructions before installing the MIA-FD ow divider. All installation activities must be
executed by specialized and qualied persons.
HYDRAULIC FLUID MINERAL OIL HL, HLP DIN 51524
FLUID CONTAMINATION (lter: ß5 >= 75 ) ISO 4406:1999 CLASS 19/17/14 (NAS 1638 class 8)
SUGGESTED VISCOSITY 20 ÷ 200 cSt
ALLOWED VISCOSITY 12 ÷ 500 cSt
ROOM TEMPERATURE -20° C ÷ 80°C
NBR SEALS FLUID TEMPERATURE ALLOWED -15° C ÷ 75°C
preciSion Grade
floW diViSion error < 1,6%
preSSure difference conSidered 170 bar
(oli VG 46 c uid and ow divider temperature< 60°)
* Values in the blue area have been calculated by interpolation, starting with many experimental tests.
For additional information, please contact our technical service.
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
+1,0%
+2,0%
0
1,6%
+0,5%
+1,5%
OIL 46 - Kinematic Viscosity [mm²/s]
10 20 30 40 50 60 70
260 130 90 46 38 26 18
Error [%]
Temperature [°C]
C1
C2
C3
C4
1000
998
995
996
5 mm
E = 0,5%
Finecorsa
End of the stroke
6
www.vivoil.com - English
dependence of the error trend from temperature/ViScoSity
The below graph shows the typical trend of the error captured during experimental tests:
The green line represents the maximum real error measured during the tests.
With oil temperatures up to 45 °C the absolute error between elements is < 0.8 % (with a pressure dierence from 0 to
180 bar)
Note: All products were tested after assembly
and an initial run time to adapt the parts to each
other. The complete adjustment requires several
hours.
Test details:
MIA-FD 6 l/min x 3 elements
Max pressure dierence between elements 170 bar
Oil Schell Tellus T 46
Oil temperature from 15°C to 75°C
Inlet ow rate18 l/min
Flexible pipes EN 853/2SN 3/8 GAS L=2000 mm
Cylinder bore ø100 mm - Cylinder rod ø50 mm - 1000 mm stroke.
floW diViSion preciSion definition:
We dene the ow division error as the dierence between the maximum and the minimum volume of ow on the outlet
of the ow divider (expressed in a percentage).
Example: One 4 element ow divider feeds 4 equal cylinders with a 1000 mm stroke.
When the rst cylinder C1 reaches the end of the stroke at 1000 mm, the other cylinders will have dierent strokes, becau-
se of the error ow division.
The dierence between the maximum stroke on C1 and mini-
mum stroke on C3 is:
1000 - 995 = 5 mm
Therefore the absolute ow division error is:
(5/1000)*100 = 0,5%
Attention! In order to express the error as a percentage, you
must calculate the maximum misalignment between all stroke
positions.
Please remember that the nal error rate is made of the ow di-
vider error, the oil compressibility, the pipes, seals and cylinders
elasticity, in addition to the volumetric eciency of the nal
uses (such as motors).
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
08
01
03
A
B
P
T
1 (P/T)
2 (T/P)
Bn
An
Bn
An
04
06
07
07
CETOP
Interface
7
www.vivoil.com - English
mia-fd floW diVider
An auto-compensating system has been added inside of the MIA-FD making the ow division does not depends on the
pressure applied on each of the elements. This system does not require any adjustments.
With this type of ow divider there is no pressure amplier eect, and therefore there is no risk of making the safety valve,
that is positioned before the ow divider ineective.
Due to the higher precision of this solution, no relief valve is necessary in the main part of the applications. Relief valves
can be installed at any time and only in the elements that need them. This is accomplished by using a CETOP connection
on top of each element.
Legend:
1(P/T) 2(T/P) CONNECTION PORTS
01 GEARS
03 CETOP CLOSING PLATE
04 INTERNAL FLOW PIPE (COLLECTOR)
An Bn IN and OUT CONNECTIONS
P T A B CETOP CONNECTING INTERFACE ON EACH ELEMENT (CONNECTING
PORTS)
06 FIXING L-SHAPE
07 M6 FIXING HOLES
08 PLUG GAUGE G1/8 (P connection)
hoW it WorkS General information
The ow divider is made up of two or more elements (sections). Inside each element there are a couple of gears that deter-
mine the quantity of oil that goes from the inlet to the outlet. The gear couples are connected mechanically so that all of
them haves a synchronized rotation.
For this reason, the ow rate that passes through each element has a constant ratio determined by the displacement of
each element.
Gears can rotate in both directions, making the ow divider reversible.
•Flow division • Flow combiner
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
01
03
04
1 (P/T)
2
(T
/P)
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
008
01
03
04
1 (P/T)
2
(T
/P)
mP
An Bn
PA
B
T
009
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
06
8
www.vivoil.com - English
floW diViSion modality
Inlet from 1 (P/T) to An: The ow is sent to the
gear element (01) that divides it into independent
ow rates. The uid goes through the compen-
sation system and feeds the P from the CETOP
connection on each element.
The CETOP closing plate (03) connects P with A
which is communicating with An.
The Bn connection is communicating with the B
port on the CETOP interface on each element.
The CETOP closing plate (03) connects B with T and
consequently is communicating with the common
line (04) and connection 2(T/P)
The Bn connection can be used for the backline
from the actuators.
floW combiner modality
Inlet form An to 1(P/T): the dierent ow rate
gets in from the An connections that are all com-
municating with the A port in the CETOP interfa-
ce of each element.
The CETOP closing plate (03) connects A with P,
then feeds the gears (01)
With this working method it is recommended
that you insert an adjustable ow regulator (06)
and assemble it (as per the scheme 2) on the ow
divider outlet in order top increase the precision.
This will slow down the descending phase and
consequently give to the gears a counterpressu-
re.
Bn connections, can be used to send oil ot the
actuators, because they are directly communica-
ting through the common line (04) to the 2 connection (T/P) .
cetop connection interface uSe on the floW diVider StaGeS:
From the above schemes :
• When the oil works as in Scheme 1 the P connection on the CETOP interface is the outlet and T is the back line.
• When the oil works as in Scheme 2, the P connection on the CETOP interface is the back line and T is the outlet.
This is really important when you are considering the use of CETOP components on top of each element.
Scheme 2
How it works as a ow combiner
Scheme 1
How it works as a ow divider
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
P
A
B
T
16,550
33,5
12,6
21,5
30,2
40,5
33
5,1
15,5
25,9
31
0,7531,75
M5 X 10
`
O
4
66,5
G3/8 X 14
`
G3/8 X 14
`
44,5
1532,552
O
25
G1/8 X 12
`
13 6,5
19,5
50
42
O
15,5
3,5
TCCE M5
Coppia di serraggio
Torque 6,9 ÷8,5 Nm
An
Bn
An
Bn
An Bn
PA
B
T
mP
9
www.vivoil.com - English
cetop interface on the floW diVider StaGeS:
Valves and modular command elements can be installed on each ow divider element.
CETOP 3 NG6 , ISO 4401-03-02-0-05.
To allow this, it is necessary to remove the CETOP closing plates.
When a CETOP element is installed, you
should always check that its characteri-
stics and use limits are appropriate to the
actual use.
You must respect all of the indications
and instructions provided by the manu-
facturer (ie: assembling, use, installation,
safety, torque couples).
The CETOP component can eect on the
nal precision, becuase it acts after the
ow compensating system, . (As an exam-
ple, the error can drastically improve be-
cause of internal leakage on an installed
CETOP component)
Vivoil Oleodinamica Vivolo declines all
possible responsibility for bad functiona-
lity of the ow divider that is generated
from equipment, valves, commands and
any other possible element that has been
installed on the ow divider or is outside
the ow divider.
CETOP CLOSING PLATES
flow divider staGes
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
0,9 250 1 2
6
1,2 250 1,5 3 7
1,7 250 2 4
9,5
2,2 250 2,5 5 13
2,6 250 3 6 16
3,2 250 3,5 7 19
3,8 250 4,5 8 22,5
4,3 250 5 9 26
4,9 250 5,5 11 29
5,9 220 6,5 13 30
6,5 220 7,5 14 33
7,8 210 8,5 17 38
9,8 200 11 22 38
0,9 250
2
4 6 8 10 12 14 16 18 20
1,2 250
3
6 9 12 15 18 21 24 27 30
1,7 250
4
8 12 16 20 24 28 32 36 40
2,2 250
5
10 15 20 25 30 35 40 45 50
2,6 250
6
12 18 24 30 36 42 48 54 60
3,2 250
7
14 21 28 35 42 49 56 63 70
3,8 250
8
16 24 32 40 48 56 64 72 80
4,3 250
9
18 27 36 45 54 63 72 81 90
4,9 250
11
22 33 44 55 66 77 88 99 110
5,9 220
13
26 39 52 65 78 91 104 117 130
6,5 220
14
28 42 56 70 84 98 112 126 140
7,8 210
17
34 51 68 85 102 119 136 153 170
9,8 200
22
44 66 88 110 132 154 176 198 220
10
www.vivoil.com - English
General inStruction
Total inlet ow rate [l/min]
Min. inlet number
suggested
< 50
1
< 90
> 90 2
Legend
Limit for MVE version
(Flow divider with relief valbe, ow rate adjustment valve
and cetop connection for command valve.)
< 50 lt/min
inStallation
Installation, initial tests, commissioning and ordinary maintenance for the ow divider must be done only by
qualied and experienced sta, who are properly equipped with the right tools and individual safety protection.
Check that the ow divider has not been damaged during the transport.
Pay close attention so you do not damage parts during the movement and assembling phases.
• Secure the ow divider on clean, at surface.
• Secure the ow divider by using the mounting brackets supplied or the threaded holes on the products sides. Secu-
ring the ow divider incorrectly can compromise the proper functionality of the system.
• To prevent additional noise caused by acoustic resonance, you should consider the use of anti-vibration mounts.
• Only remove the plugs immediatly before you connect the pipes.
• Pay careful attention so you do not introduce dirt into the ports or the CETOP connections
Displac.
cm
3
/rev
P.max
bar
Optimal ow rate
for an element
[l/min]
TOTAL INLET FLOW RATE [l/min]
ELEMENT NUMBER:
2 3 4 5 6 7 8 9 10
floW rate definition
The table shows the operating range of the individual elements of the
ow divider.
Higher ow rates with the same gear displacement, improve the preci-
sion, but cause a higher pressure loss and higher noise levels. For this
reason we suggest, whenever it is possible, the use of a ow rate close to
the optimal value dened in the table.
Its important to check the ow rate for each element, even for the combi-
ning phase.
Working pressures indicated must be considered maximum continuous
values.
Pressure peaks of approximately 10 percent are allowed.
inlet number definition
With inlet ow rates of over 80÷90 l/min, we
suggest you to contact our technical service to
evaluate additional inlet port addition.
Displac.
cm
3
/rev
P.max
bar
WORKING RANGE
Flow Rate per element [l/min]
Min.
Optimal
Max
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
11
www.vivoil.com - English
• Use only cylindrical ttings BSPP suitable to the working pressure. The use of conical tting is absolutely not allo-
wed.
• Flexible or rigid pipes must conform to the maximum nominal pressures, respect minimal radii of curvature and be
positioned so as not to transfer mechanical stress to the ow divider.
commiSSioninG
• Execute all of the proper connections
• Check that all of the valves that can inuence the pressure are adjusted to the minimal values during the rst start up.
• Check that no valves, taps, plugs, ow restrictors or other elements, that can obstruct or restrict the oil ow or impro-
ve the pressure, are present after the ow divider.
• Check the proper connection tightening and the proper circuit positioning
• Always respect the recommendations and instructions from the machine builder, where the ow divider is
installed, concerning safety and how to install pipes, valves, electrical connentions, etc.
• Start the ow divider for a short period with no load on the uses
• Immediately stop the use if any strange noise, leakages, strange movements, etc. cause you to doubt or suspect there
are issue with the proper functionality.
• Purge the air from the circuit. In order for the ow divider to work properly, no air should be present in the circuit (no
foam in the tank).
• Perform many cycles without load on the uses.
• With all the actioning deactivated and no pressure on all the pipes, check that no leakage occurs and that all pipes,
ttings and connections have been properly tightened
• Adjust the valves and perform some empty cycles.
• After all the steps before have been succesfully passed, start by gradually adding the load on the uses on step at a
time.
uSe
• The ow divider must be used within the limits provided by this catalogue.
• Use the type of oil suggested in this catalogue.
• Take care of the oil ltration because contamination can irreparably damage the ow dividers precision and cause a
lifetime reduction.
• Do not exceed the temperature indicated in this catalogue
• Check that no air is in the circuit (no foam in the tank).
• If CETOP valves are applied on the ow divider, respect the user instructions from the manufacturer.
• Always respect the recommendations and instructions from the machine builder where the ow divider is
installed concerning safety.
maintenance
The user must periodically check:
• No leakage should be present between the elements.
• Fittings and xing screws should be properly tightened.
• Valves and plugs should be properly tightened.
• Never exceed the tightening torque values indicated in the catalogue and from the components manufacturers.
Note When leakage is found and the tightening is correct, do not tighten more, instead replace the seals. This operation has
to be done by qualied and experienced sta.
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
0,9 16 74,5 250 1 2 6 2,3
1,2 17 75,5 250 1,5 3 7 2,3
1,7 18 77 250 2 4 9,5 2,3
2,2 20 79 250 2,5 5 13 2,4
2,6 21 81 250 3 6 16 2,4
3,2 23 83 250 3,5 7 19 2,5
3,8 25 85 250 4,5 8 22,5 2,5
4,3 27 87 250 5 9 26 2,6
4,9 29 90 250 5,5 11 29 2,7
5,9 31 93,5 220 6,5 13 30 2,8
6,5 32 96 220 7,5 14 33 2,8
7,8 34 100 210 8,5 17 38 3,0
9,8 36 109 200 11 22 38 3,2
MVA
NN
CC
MVA
NN
CC CC CC CC
12
www.vivoil.com - English
TOTAL ELEMENT NUMBER
mva - standard flow divider
Standard ow divider with 3/4 BSPP inlet and outlet ports
Displ.
cm
3
/rev
Code
CC
A
P.max
bar
Flow Rate per element [l/min]
Element
weight
kg
Min. Optimal Max
orderinG code
flow divider with equal displacements:
TOTAL ELEMENT NUMBER
Example:
4 Element ow divider 3,8+4,9+4,9+6,5
cod. MVE 04 25 29 29 32
* Note: To dene the code for dierent displacement version
with more than 7 element please contact sales.
Right Cover Weight = 0,8 kg
Left Cover Weight = 0,6 kg
flow divider with different displacement elements (max. 7*):
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
0,9 2 l/min 194 230 5,9 268,5 304,5 8,2 343 379 10,4 417,5 453,5 12,7 492 528 14,9 566,5 602,5 17,2 641 677 19,4
1,2 3 l/min 196 232 6,0 271,5 307,5 8,2 347 383 10,5 422,5 458,5 12,8 498 534 15,1 573,5 609,5 17,3 649 685 19,6
1,7 4 l/min 199 235 6,0 276 312 8,4 353 389 10,7 430 466 13,0 507 543 15,3 584 620 17,6 661 697 20,0
2,2 5 l/min 203 239 6,2 282 318 8,5 361 397 10,9 440 476 13,3 519 555 15,7 598 634 18,0 677 713 20,4
2,6 6 l/min 207 243 6,3 288 324 8,7 369 405 11,1 450 486 13,6 531 567 16,0 612 648 18,4 693 729 20,8
3,2 7 l/min 211 247 6,4 294 330 8,9 377 413 11,3 460 496 13,8 543 579 16,3 626 662 18,8 709 745 21,3
3,8 8 l/min 215 251 6,5 300 336 9,0 385 421 11,6 470 506 14,1 555 591 16,7 640 676 19,2 725 761 21,7
4,3 9 l/min 219 255 6,6 306 342 9,2 393 429 11,8 480 516 14,4 567 603 17,0 654 690 19,6 741 777 22,2
4,9 11 l/min 225 261 6,8 315 351 9,4 405 441 12,1 495 531 14,8 585 621 17,5 675 711 20,2 765 801 22,8
5,9 13 l/min 232 268 7,0 325,5 361,5 9,7 419 455 12,5 512,5 548,5 15,3 606 642 18,1 699,5 735,5 20,8 793 829 23,6
6,5 14 l/min 237 273 7,1 333 369 9,9 429 465 12,8 525 561 15,6 621 657 18,5 717 753 21,3 813 849 24,2
7,8 17 l/min 245 281 7,3 345 381 10,3 445 481 13,2 545 581 16,2 645 681 19,1 745 781 22,1 845 881 25,1
9,8 22 l/min 263 299 7,8 372 408 11,0 481 517 14,2 590 626 17,4 699 735 20,6 808 844 23,8 917 953 27,1
1 (P/T)
2
(T/P)
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
13
www.vivoil.com - English
Displ.
cm
3
/rev
Code
CC
A
P.max
bar
Flow Rate per element [l/min]
Element
weight
kg
Min. Optimal Max
Note:
• For ow dividers with more than 8 elements and/or global inlets of more than 90 l/min, we suggest you contact our techni-
cal deptartment to evaluate if an additional inlet or more than one is required.
Displacement
cm
3
/rotation
Optimal sin-
gle element
ow rate
ELEMENT NUMBER
2 3 4 5 6 7 8
Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg
dimenSionS of an aSSembled floW diVider (from 2 to 8 elementS)
exploded VieW With couplinG torque ValueS
hydraulic symbol
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
MVE
NN
CC
M
A 10 ÷ 105 bar
B 70 ÷ 210 bar
C 140 ÷ 350 bar
0,9 16 74,5 250 1 2 6 2,3
1,2 17 75,5 250 1,5 3 7 2,3
1,7 18 77 250 2 4 9,5 2,3
2,2 20 79 250 2,5 5 13 2,4
2,6 21 81 250 3 6 16 2,4
3,2 23 83 250 3,5 7 19 2,5
3,8 25 85 250 4,5 8 22,5 2,5
4,3 27 87 250 5 9 26 2,6
4,9 29 90 250 5,5 11 29 2,7
5,9 31 93,5 220 6,5 13 30 2,8
6,5 32 96 220 7,5 14 33 2,8
7,8 34 100 210 8,5 17 38 3,0
9,8 36 109 200 11 22 38 3,2
M
MVE
NN
CC CC CC CC
14
www.vivoil.com - English
TOTAL ELEMENT NUMBER
mve - flow divider with command connection (up to 50l/min)
Flow divider with command CETOP connection, relief valve, ow rate valve and unidirectional ow
rate adjustment to lead the reunication phase.
TOTAL ELEMENT NUMBER
orderinG code
flow divider with equal displacements:
Example:
4 Element ow divider 3,8+4,9+4,9+6,5
with relief valve 70÷210 bar
cod. MVE 04 B 25 29 29 32
* Note: To dene the code for dierent displacement version
with more than 7 element please contact sales.
flow divider with different displacement elements (max. 7*):
Displ.
cm
3
/rev.
Code
CC
A
P.max
bar
Flow Rate per element [l/min]
Element
weight
kg
Min. Optimal Max
Right Cover Weight = 2,9 kg
Left Cover Weight = 0,6 kg
Setting range
of the valve
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
mP
An Bn
PA
B
T
P T
PA
B
T
018
0,9 2 l/min
258,5 294,5 8,0 333 369 10,3 407,5 443,5 12,5 482 518 14,8 556,5 592,5 17,0 631 667 19,3 705,5 741,5 21,5
1,2 3 l/min
260,5 296,5 8,1 336 372 10,4 411,5 447,5 12,7 487 523 14,9 562,5 598,5 17,2 638 674 19,5 713,5 749,5 21,8
1,7 4 l/min
263,5 299,5 8,2 340,5 376,5 10,5 417,5 453,5 12,8 494,5 530,5 15,1 571,5 607,5 17,5 648,5 684,5 19,8 725,5 761,5 22,1
2,2 5 l/min
267,5 303,5 8,3 346,5 382,5 10,7 425,5 461,5 13,0 504,5 540,5 15,4 583,5 619,5 17,8 662,5 698,5 20,2 741,5 777,5 22,5
2,6 6 l/min
271,5 307,5 8,4 352,5 388,5 10,8 433,5 469,5 13,3 514,5 550,5 15,7 595,5 631,5 18,1 676,5 712,5 20,6 757,5 793,5 23,0
3,2 7 l/min
275,5 311,5 8,5 358,5 394,5 11,0 441,5 477,5 13,5 524,5 560,5 16,0 607,5 643,5 18,5 690,5 726,5 20,9 773,5 809,5 23,4
3,8 8 l/min
279,5 315,5 8,6 364,5 400,5 11,2 449,5 485,5 13,7 534,5 570,5 16,3 619,5 655,5 18,8 704,5 740,5 21,3 789,5 825,5 23,9
4,3 9 l/min
283,5 319,5 8,7 370,5 406,5 11,3 457,5 493,5 13,9 544,5 580,5 16,5 631,5 667,5 19,1 718,5 754,5 21,7 805,5 841,5 24,3
4,9 11 l/min
289,5 325,5 8,9 379,5 415,5 11,6 469,5 505,5 14,3 559,5 595,5 16,9 649,5 685,5 19,6 739,5 775,5 22,3 829,5 865,5 25,0
5,9 13 l/min
296,5 332,5 9,1 390 426 11,9 483,5 519,5 14,7 577 613 17,4 670,5 706,5 20,2 764 800 23,0 857,5 893,5 25,8
6,5 14 l/min
301,5 337,5 9,2 397,5 433,5 12,1 493,5 529,5 14,9 589,5 625,5 17,8 685,5 721,5 20,6 781,5 817,5 23,5 877,5 913,5 26,3
7,8 17 l/min
309,5 345,5 9,5 409,5 445,5 12,4 509,5 545,5 15,4 609,5 645,5 18,3 709,5 745,5 21,3 809,5 845,5 24,2 909,5 945,5 27,2
9,8 22 l/min
327,5 363,5 10,0 436,5 472,5 13,2 545,5 581,5 16,4 654,5 690,5 19,6 763,5 799,5 22,8 872,5 908,5 26,0 981,5 1017,5 29,2
15
www.vivoil.com - English
Note:
• For ow dividers with more than 8 elements and/or global inlets of more than 90 l/min, we suggest you contact our techni-
cal deptartment to evaluate if an additional inlet or more than one is required.
dimenSionS of an aSSembled floW diVider (from 2 to 8 elementS)
exploded VieW With couplinG torque ValueS
hydraulic symbol
Displacement
cm
3
/rotation
Optimal sin-
gle element
ow rate
ELEMENT NUMBER
2 3 4 5 6 7 8
Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg Ld Li kg
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
Coppia di serraggio 50÷60 Nm
(Torque)
021
0
7
30 9060
Q (l/min)
ΔP (bar)
n. giri della regolazione
Valvola aperta
14
21
3 2 1
35 cSt T= 50°C
315
210
105
0
15 30 45 60
Coppia di serraggio 50÷60 Nm
(Torque)
Q (l/min)
ΔP (bar)
019
T
P
T
P
16
www.vivoil.com - English
relief ValVe (50 l/min)
Max ow rate 50 l/min
Max pressure in P 350 bar
Max pressure in T 210 bar
Spring range 01 10÷105 bar
Spring range 02 70÷210 bar
Spring range 03 140÷350 bar
Filtering required 19/15 ISO 4466 (25 μm absolute)
Oil viscosity range allowed 2.8 ÷ 350 cSt
Temperature range -20 +80 °C
Standard seals material Poliuretan Buna N
Weight 0,270 kg
Percentage of the set value to open 95% (dened with 1 i/min)
Percentage of the set value to close 75% (dened with 1 i/min)
Hydraulic oil Mineral oil HM e HV ISO 6074
ValVeS characteriSticS
floW rate adjuStment ValVe (50 l/min)
Max ow rate adjustable (Δp 7 bar) 0 ÷ 50 l/min
Max ow rate adjustable (Δp 14 bar) 0 ÷ 70 l/min
Max pressure 350 bar
Filtering required 19/15 ISO 4466 (25 μm absolute)
Oil viscosity range allowed 2.8 ÷ 350 cSt
Temperature range -20 +80 °C
Standard seals material Poliuretan Buna N
Weight 0,170 kg
Hydraulic oil Mineral oil HM e HV ISO 6074
Note
Total valve regulation is done by 4 spin.
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
An Bn
PA BT
P T
PA BT
An Bn
PA BT
An Bn
PA BT
An Bn
PA BT
A B
P T
MAX
MIN
MVE-ES-01
An Bn
PA BT
1 P/ T
2 T / P
An Bn
PA BT
An Bn
PA BT
An Bn
PA BT
MAX
MIN
A B
P T
MVA-ES-01
1 P/ T
2 T / P
An Bn
PA BT
An Bn
PA BT
MAX
MIN
A B
P T
MVA-ES-02
P T
PA BT
A B
P T
MAX
MIN
MVE-ES-02
An Bn
PA BT
An Bn
PA BT
mVemVa
mVemVa
17
www.vivoil.com - English
exampleS
2 Elements Flow Divider
Relief valves installed on the elements CETOP to realign
the actuators at the end of the stroke.
2 Elements ow divider with integrated relief valve and ow rate
regulator. On the CETOP a command valve installed.
Relief valves installed on the elements CETOP to realign the actua-
tors at the end of the stroke.
Standard 4 elements ow divider
4 elements ow divider with integrated relief valve and ow
rate regulator.
On the CETOP a command valve installed.
Vivoil Oleodinamica Vivolo s.r.l - Società a Socio Unico - via Leone Ginzburg 2-4 40054 Budrio (BO) Italy tel: +39 051 803689 fax: +39 051 800061
VIVOIL OLEODINAMICA VIVOLO
M
ANIFOLD
INSTANTANEOUS
A
UTO
-
COMPENSATING
F
LOW
D
IVIDER
MIA - FD
1 P/ T
2 T / P
An Bn
PA BT
An Bn
PA BT
MAX
MIN
A B
P T
MVA-ES-03
P T
PA BT
A B
P T
MAX
MIN
MVE-ES-03
An Bn
PA BT
An Bn
PA BT
P T
PA BT
A B
P T
An Bn
PA BT
An Bn
PA BT
MVE
1 P/ T
2 T / P
An Bn
PA BT
An Bn
PA BT
MVA
An Bn
PA BT
An Bn
PA BT
P T
PA BT
A B
P T
A B
A B
P T
MVE
mVa mVe
18
www.vivoil.com - English
2 Elements ow divider with integrated relief valve and ow rate
regulator. On the CETOP a command valve installed.
Relief valves installed on the elements CETOP to realign the actua-
tors at the end of the stroke.
Electrical check valves on each element CETOP interface.
2 Elements Flow Divider with electrical check valves on
each element CETOP interface
2 Elements ow divider with integrated relief valve and ow
rate regulator. On the CETOP a command valve installed.
Relief valves installed on the elements CETOP to realign the
actuators at the end of the stroke.
On the single elements CETOP, piloted nonreturn valves.
Flow divider with overcenter valves on
each CETOP.
2 Elements ow divider with integrated relief valve and ow rate regu-
lator. On the CETOP a command valve installed.
Relief valves installed on the elements CETOP to realign the actuators at
the end of the stroke.
On the single element CETOP, independent 3 position controls.
Vivoil Oleodinamica Vivolo has the right to change the contents of this document and it is not obliged to advise anyone, in order to keep them aligned with
the technical progress achieved.
All drawings and information in this document are Vivoil Oleodinamica Vivolo s.r.l. property.
VIVOIL OLEODINAMICA VIVOLO
Vivoil Oleodinamica Vivolo s.r.l
Via Leone Ginzburg 2-4 40054 Budrio (Bo) Italy
Tel +39 051 803689 - Fax+39 051 800061
site : www.vivoil.com