Total leakage is the sum of each section loss at its operating
INTERNAL LEAKAGE (TYPICAL)
viscosity if internal leakage is more than 50% of theoretical flow.
Do not operate pump more than 5 seconds at any speed or
Lp. Noise level {db(A)} 1m ISO 4412
10
55
60
Pressure in bar (psi)
10050 140 210175 240
65
70
75
NOISE LEVEL (TYPICAL)
VT6CC - 022 - 022
HYDROMECHANICAL POWER LOSS (TYPICAL) PERMISSIBLE RADIAL LOAD
Speed n ( rpm )
Maximum axial load permissable = 800 N (180 Lbs)Fa
Double pump noise level is given with each section discharging at
the pressure noted on the curve.
Total hydromechanical power loss is the sum of each section at its
operating conditions.
32 cSt
= Lp + 8 db (A)
n = 1000 RPM
n = 1500 RPM
Lw
Viscosity
Inlet pressure 0.9 bar abs
conditions.
(2000)(500) (1000) (1500)
(1.0)
(1.5)
(5.0)
(3.0)
(2.0)
(4.0)
(5.5)
(6.5)
(3000)(2500)
(2175) (2700)
(4000)(3500)
Pressure in bar (psi)
(1500)(100) (725) (2000) (2500) (3000) (3500)
(2000)
P1-P2
P1-P2
P1-P2
(500)
0
0
(1500)(1000)
7035 105
1
2
n = 1500 rpm (24 cSt)
3
4
n = 1000 rpm
5
n = 2800 rpm
800
1500
(3000)(2500)
(2175) (2700)
175160140 210190
(3500) (4000)
240 275
600
200
1000 1200
400
600
1800 2000 2500 2800
1000
1200
Shaft keyed N° 1
F
Fa
1400
= =
Pressure in bar (psi)
P1-P2
105700 35
0
4
6
240210175140 160 190 275
P1-P2
12
9
15
18
24
21
24 cSt
10 cSt
(45)
(90)
(136)
(182)
(227)
(272)
(318)
Internal leakage Qs in lpm (Gpm)
Power loss Ps (hp)
Load F in N (Lbs)
W version
Use for severe duty shaft only
VT6CC W - 022 - 008 -1 R 00 - C 1 - 00 *
Type of shaft
5 - splined (SAE B)
3 - splined (SAE BB)
1 - keyed (no SAE)
Cam ring for "P1" & "P2"
Series
L - counter-clockwise
Direction of rotation
(view on shaft end)
Porting combination (see page BM-1-5)
00 - standard
Design letter
R - clockwise
1) for 46 ml/rev max.
5 - S5 (for mineral oil and fire resistant fluids)
4 - S4 (for fire resistant fluids)
Modifications
1 - S1 (for mineral oil)
Seal class
mounted in the front.
Mounting W/connection variables
The large cartridge must be always
2) for 126 ml/rev max.
2 - keyed (SAE BB)
S - splined (DIN 5462)
for cold start
'Y' - Bi - directional '0' - Uni - directional
*
'B' - Bi - directional
Volumetric displacement cm³/rev (in3/rev)
015/B15/Y15
025/B25/Y25
031/B31/Y31
028/B28/Y28
022/B22/Y22
020/B20/Y20
017/B17/Y17
21.3 (1.30)
010/B10/Y10
014/B14/Y14
012/B12/Y12
008/B08/Y08
46.0 (2.81)=
34.1 (2.08)
37.1 (2.26)
26.4 (1.61)
=
=
=
003/B03/Y03
006/B06/Y06
005/B05/Y05
*
10.8 (0.66)
17.2 (1.05)
=
=
=
79.3 (4.84)
100.0 (6.10)=
88.8 (5.42)
=
=
70.3 (4.29)=
58.3 (3.56)
63.8 (3.89)
=
=
50.5 (3.08)=
P1
P2
P2
code
11100100Unc
0M
Metric
W0
W11M
P1=1" - S=3"
1"
1)
3/4" 3/4"
1"
P1=1 - " S=2 "
2)
1)
½
BI-1-12
HIGH PERFORMANCE VANE PUMP VT6CC
DP