Directional Control Valves
4D01
THIS P
AGE INTENTION
ALL
Y LEFT BLANK
VELJAN model V4D01 direct operated Directional Control valves conform to
NFPA D03, NG 6 (CETOP 03) standard interface. These are subplate and
manifold mounted and can be used in conjunction with stack valve system.
The valve mounting interface and electrical connection methods conform to
international standards CETOP, ISO, DIN. The coils used in the wet pin design
solenoids are available in A.C. and D.C. voltages and are continuously rated.
Precise guide for all types of spools are achieved by uniquely designed five
annuli body. Spools are interchangeable and no selective assembly is necessary.
a
o
A B
P T
b
Example:
b
a
¨ Low pressure drop for reduced heat loss and increased efficiency.
¨ Compact five annuli body design.
¨ Mounting configuration according to CETOP R35H, ISO 4401 and DIN 24340
¨ Wide variety of spool types including detent, and interchangeable spools and bodies.
¨ Actuated by electrical / hydraulic / pneumatic / cam or lever mechanism.
¨ Wide range of A.C. and D.C. coil voltages are available both with or without manual override.
¨ Low electrical power consumption ( 29 W / 24 V DC )
¨ Quick change of solenoid coil without risk of oil leakage.
¨ Solenoid coil can be positioned at 90° intervals with respect to body .
¨ Upto 210 bar pressure allowable at tank port .
¨ Electrical connection by standard 3 pin connector according to DIN 43650 , ISO 4400 or
with Wiring box.
¨ Optional plug-in connector with LED display are available.
¨ Every valve is factory tested prior to despatch.
Features
DIRECTIONAL CONTROL VALVES - 4D01
DC
DC
DC-01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
Characteristics
Orifice
Depending on the operating conditions flow from the valve can be limited by using
orifice plug at port P. Consult model code for orifice sizes.
OPERATION
The Directional Control valve V4D01 consists of a body, spool and either one or two actuators depending
upon the application. The spool is shifted by the action of electrical solenoid, mechanical, hydraulic, pneumatic,
cam or lever actuator mechanism. Spool movement allows oil under pressure from port P to flow to either
port A or B, and subsequently connect the other port to tank. On de-energizing the actuator, the spool is
returned to the center position or offset position. Manual operation of spool is possible using the optional manual
override system .
Brad Harisson or
(Optional) Cannon
14S Connector
A P B
(T)
A T B
(P)
Design Sliding spool valve
Type of Mounting Subplate
Mounting Position Optional but horizontal recommended
Ambient temperature range 0....120°F (-18 ....+50°C)
Operating Pressure(P,A,B) 350 bar (5000 psi)
Permissible pressure T up to 210 bar (3000 psi)
Max. flow 21,1 GPM(80 l/min.) (see diagram - Pressure drop curves)
Fluid Mineral oil according to DIN 51524 and 51525
Viscosity range 10....650 cSt, optimum 30 cSt
Fluid temperature range 0....176°F(-18....+80°C)
Contamination level Max. permissible contamination level
according to NAS 1638 Class 8 (Class 9
for 15 Micron and smaller or ISO 17/14)
DIRECTIONAL CONTROL VALVES - 4D01
DC
DC
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-02
PRESSURE DROP
SOLENOID CHARACTERISTICS
see ordering code
20 W
45 VA
199 VA
± 10%
135 °C (275° F)
100%
IP 65
H
14400
see ordering code
29 W
± 10%
105 °C (220° F)
100%
IP 65
F
14400
A.C. D.C.
Nominal Voltage
Power Input
Holding Power
Inrush Power
Permissible Voltage difference
Maximum coil temperature
Relative Operating Period
Type of Protection
Insulation Class
Cycle (1/H)
80 (21.2)60 (15.9)40(10.6)20 (5.3)
0
Fluid 40 cSt at 50° C (120° F)
Flow l/min. (gpm)
l
Pressure drop bar (psi)
4 (58)
0
8 (116)
16 (232)
12 (174)
20 (290)
g
k
I
a
f
c
b
e
d
h
Performance data given is typical and can be influenced by application.
Spool Type
d
d
-
I
91
e
lk
f
-
gg
-
d
a
e
a
l
d
cc
a
b
l
d
cc
-
gg
-
d
e e
kl
-
b
--
I
--
d
e
a c
d
l
01
d
e
a c
d
l
0302 090807
b
hl
g
e
------
h
cc
f
a
-
kk
-
52
h
cc
f
e
a
1211
10 5146
h
g
b
l
6456
55
8165
-
-
k
k
k
0C
g
g
-
-
f
I
c
e
c
e
a
--
b
b
a
0X0Y
P T
A T
B T
P A
P B
DIRECTIONAL CONTROL VALVES - 4D01
DC-03
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
SPOOL POSITIONS
Spring Offset
2 Position Detent
b,a
5
b,X
b
2
1
a
3
A B
P T
b
a
a,Y
Spool
Position 09
Only For Spool Types
(11, 51, 12)
Except for spools 81, OC, OY
Spring Centered
3 Position Detent
Spool
Position 07
a
P T
A B
o
b
b,o,a
5
*
*
*
**
**
**
OC
a
b
a
OY
b
91
a
b
81
b
a
52
a
b
51
a
b
b
12
a
b
11
a
a
81
OY
a
a
OC
b
b
b
**
*
Standard Spools
Spool Position 01 only
Spool Position 02 only
OX
65
64
56
55
46
10
09
08
07
03
01
02
o
o
o
o
o
o
o
o
o
o
o
o
o
a
a
a
a
a
a
a
a
a
a
b
b
b
b
b
b
b
b
b
b
b
b
b
a
a
a
4
b
2
3
1
b,X
P T
a
b
A B
o
4
a
P T
o
A B
b
a
2
a,Y
3
1
Spool
Position 05
3
1
b
2
b,X
a
A B
o
P T
b,a
5
a
b
a,Y
Spool
Position 06
Spool
Position 03
Spool Types Caps
b
4
b
b,X
2
3
P T
1
A B
a
b
a
a
b
A B
P T
4
a
1
3
a,Y
2
Spool
Position 01
For (11, 12, 51)
Spool
Position 02
For Spool Types
(11, 12, 51)
Pneumatic Operation
Cam Operation
Hydraulic Operation
Solenoid Operation
Lever Operation
2
4
3
1
5
oa
b
13
DIRECTIONAL CONTROL VALVES - 4D01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-04
DC
DC
DIRECTIONAL CONTROL VALVES - 4D01
DC-05
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
Seal Class
1 = NBR-seals (Standard)
5 = FPM-seals (Viton)
Design Letter
B
Solenoid Voltage
V4D01 - 3202 - 0701 - B1 W07 -
Series
Cetop 03
Body
3 = Standard (not for spools 55,56)
F = only for spools 55,56
H= Bottom connection for Hyd. Operation
Control
1 = 1 Solenoid
2 = 2 Solenoids
4 = Lever Operated
5 = Cam Operated
*7 = 2 solenoids, 2 pos. detents
D = Pneumatic operation, one-sided
E = Pneumatic operation, both sides
*F = Pneumatic operation, both sides
(2 pos. detents)
Q = Hydraulic operation, one-sided
R = Hydraulic operation, both sides
*S = Hydraulic operation, both sides
(2 pos. detents)
*(ONLY FOR SPOOLS 11, 12, 51, 52 AND 91)
Spool Type
Refer to page No. 4
Spool Position
01=2(a,b),Spring offset pos. "b"; activated to "a"
02=2(a,b),Spring offset pos. "a"; activated to "b"
03=3(a,o,b),Spring centered pos. "o"
05=2(o,b),Spring centered pos "o"; activated to "b"
06=2(o,a),Spring centered pos. "o"; activated to "a"
07=3 pos. detents (for control 4 only)
09=2 pos. detents (for control 4,7,F & S)
End Cap
01 = for control 1,D,Q
02 = for control 2, 7, E, F, R & S
04 = for control 4 & 5
05 = for control 4 & spool position 07 & 09
OH = for control 1 with inductive detector: "a" or
“b" position controlled
Valve Accessories /
Modifications
** ** **
08 = Orifice of 0,8 mm dia in
P-port
10 = Orifice of 1,0 mm dia in
P-port
12 = Orifice of 1,2 mm dia in
P-port
27 = Plug-in connector
28 = Wiring box and flying leads
w/o terminal strip
38 = Plug-in connector and
manual override and orifice
1mm dia. in P-port
49 = Wiring box and Brad
Harrison Connector
51 = Plug-in connector, manual
over-ride and indicator lamps
52 = Plug-in connector and
manual over-ride and
rubber cover
61 = Wiring box and indicator
lamps
62 = Wiring Box with indicator
lamps and Brad Harrison
Connector
81 = Wiring Box and flying leads
with terminal strip
G3 = Anchor tube with manual
overirde and soft shift orifice
(only DC)
(Omit for controls 4,5,D,E,F,Q,R,S)
W01 = 115V/60 CY AC GOR = 12V DC
W02 = 230V/60 CY AC GOQ = 24V DC
W06 = 115V/50 CY AC
W07 = 230V/50 CY AC
W54 = 110V/50 CY AC
W57 = 220V/50 CY AC
ORDERING CODE
FUNCTIONAL LIMITS
8
5 4
6
123
11
10
7
9
200 (2857)
Pressure bar (psi)
Flow l/min (gpm)
60
(15.9)
50 (714)
0
100
(2.65)
40
(10.6)
20 30
(5.3) (7.9)
50
(13.2)
100 (1429)
150 (2143)
(21.2)
8070
(18.5)
250 (3570)
300 (4286)
Valve with Standard DC-solenoid
350 (5000)
Functional Limits are with warm solenoid operated at 10
undervoltage. The flow data corresponds to 2 flow directions
(eg. P to B and simultaneously from A to T). In case of single
flow direction only (4-Way-Valve used as 3-Way-Valve) the
permissible flow must be reduced.
() Curves for spool with detents
1) Only if port A and B is closed
OC
OY
OX
46
51
52
65
81
91
55
56
64
10
11
1)
12
07
08
09
01
02
03
Spool type
Curve no.
DC AC
1
11
11
3
2(1)
6(8)
5
3
(1)
9
9
5
10
2(1)
6(8)
5
7
10
4
9
1
2
6
2
5
3
2 7 1
4
6
8
4
9
200 (2857)
Pressure bar (psi)
50 (714)
0
0 10 20
(2.65) (5.3)
100 (1429)
150 (2143)
Flow l/min (gpm)
(18.5)
50
(13.2)
4030
(10.6)(7.9)
60 70
(15.9)
80
(21.2)
Valve with Standard AC-solenoid
250 (3570)
300 (4286)
350 (5000)
3
2
7
7
1
5
4
2
5
9
9
3
3
1
1
1
8
8
DIRECTIONAL CONTROL VALVES - 4D01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-06
DC
DC
45.0
264.0
132.0
40.5
17.0
77.0
31.0
32.5
8.78
1.77
Ø0.21
0.87
4.72
2.28
0.94
Ø0.35
223.0
45.0
22.0
Ø5.3
111.5
58.0
24.0
Ø9.0
A4
A6
A8
A7
A5
mm
in
A2
A3
A1
Dimensions
B4
1.77
B6
5.20
B5
10.40
Dimensions
in
B2
1.59
B3
0.67
B1
3.03
mm
1.22
B7
1.28
B8
36 (1.42)
A B
Plug-in connectors according to ISO 4400
1 & 2 - SOLENOID AC / DC OPERATED VERSIONS
3 PIN CONNECTOR
Port Functions:
P = Pressure
T = Tank
A+B = User
ØA8
A4
A7
A6
A2
A5
A3
solenoid a
solenoid b
Manual override
ØA1
Weight
AC
DC
Single Solenoid
Double Solenoid
3.8 lbs
4.2 lbs
(1.91Kg)
4.5 lbs
(2.05 Kg)
(1.91 Kg)(1.73Kg)
4.2 lbs
Tighting Torque : 9NM (Approx)
B1
B3
B2
B5
B6
P
A
B
T
Rubber
cover and
manual over
ride
Coil can be
placed in any
position
B7
B8
B4
VELJAN HYDRAIR PVT. LTD.
MADE IN INDIA
with LED (red) 15 ... 30V
with bridge rectifier 12 ... 250V
Voltage >250V
Standard
Versions
PG11
PG11
ISO 4400
V 167-01101-8V 167-01100-8
V 167-01014-8V 167-01076-8
V 167-01020-8
V 167-01008-8
B-Side
V 167-01007-8
V 167-01019-8
A-Side
DIRECTIONAL CONTROL VALVES - 4D01
DC-07
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
B7
B8
B3
B5
B6
B4
B1
B2
B9
mm
in
Dimensions
132.0
51.0
40.5
31.0
264.0
45.0
77.0
17.0
32.5
5.20
2.01
1.59
1.22
10.4
1.77
3.03
0.67
1.28
4.51
Ø 0.21
0.87
2.01
9.02
1.95
3.13
0.94
4.00
Ø0.35
A9
A10
A5
A7
A8
A6
A3
A4
A2
A1
mm
in
Dimensions
114.5
Ø 5.3
22.0
229.0
51.0
49.5
79.5
24.0
101.5
Ø9.0
B4
B8
B6
B1
B2 B3
B5
B7
Rubber cover
and Manual override
P
T
VELJAN HYDRAIR PVT. LTD.
MADE IN INDIA
A
B
B9
A3
A2
A4
A8
A5
A6
A9
A7
A10
½" NPT
½" NPT
Manual Override
ØA1
(2.33 Kg)
(2.51 Kg)
5.1 lbs
5.5 lbs 5.8 lbs
5.5 lbs
(2.65 Kg)
(2.51 Kg)
Weight
AC
DC
Single Solenoid
Double Solenoid
1 & 2 - SOLENOID AC / DC OPERATED VERSIONS
WIRING BOX
Port Functions:
P = Pressure
T = Tank
A+B = User
DIRECTIONAL CONTROL VALVES - 4D01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-08
DC
DC
Port function
P = Pressure
T = Tank
A+B = User
LEVER OPERATED VERSION
CAM OPERATED VERSION
B6
A6
A4
A5
B2 B3
B1
B7
A
B
B4
VELJAN HYDRAIR PVT. LTD
MADE IN INDIA
P
T
B6
A8
ØA1
A7
A3
A2
B8
P0S. a
P0S. b
P0S. 0
5.65
B5
143.5
98.5
27.51.08
B7
B6
3.88
77.0
17.0
40.5
45.0
1.59
B3
B4
1.77
B1
B2
3.03
0.68
1.22B8
31
mm
in
Dimensions
mm
in
A4
A6
A8
A7
A5
A2
A3
A1
Dimensions
53.0
Ø5.3
141.0
22.0
24.0
40.5
40.5
Ø9.0
2.09
0.87
Ø0.21
5.55
0.95
1.59
1.59
Ø0.35
07, 64, 65
01, 02, 03, 08, 09, 10, 46,
55, 56, OX
160 bar (2300 psi)
30 Newtons (6.7 lbs)
10.6 GPM (40 l/min.)
15,9 GPM (60 l/min)
3.8 lbs (1.73 kg)
±17.5°
Max. Tank Pressure
Weight
Functional Limits
at 350 bar (5000 psi)
Operating force
Angle of operation
Applicable for spool numbers
22.0
8.0
31.0
32.5
B5
B7
B6
77.0
17.0
40.5
45.0
B3
B4
B1
B2
1.59
1.77
3.03
0.68
0.87
0.31
1.22
1.28
B8
mm
in
Dimensions
Ø9.0
50.0
164.2
69.7
Ø5.3
22.0
22.0
24.0
Ø0.21
0.87
0.87
0.95
Ø0.35
1.97
6.46
2.74
mm
in
A4
A6
A8
A7
A5
A2
A3
A1
Dimensions
at operating pressure bar (psi)
Operating Force Newtons (lbs)
100
(1430)
Without Tank Pressure
200
(2860)
350
(5000)
With Tank Pressure
Max. 20 bar (286 psi)
100
(22.5)
160
(36)
120
(27.0)
140
(31.5)
180
(40.5)
200
(45.0)
Functional Limits
at 350 bar (5000 psi)
Weight
01, 02, 03, 08, 09, 10, 11, 46,
51, 55, 56, 81, 91, 0C
2.6 GPM (10 l/min.)
3,1 lbs (1.41 Kg)
9.3 GPM (35 l/min.)
15,9 GPM (60 l/min)
applicable for spool numbers
12, 52
07, 64, 65, OY, OX
B3
B1
B2
B5
B6
B4
VELJAN HYDRAIR PVT. LTD
MADE IN INDIA
T
P
B
A
B7
B8
A3
A1
A4
A6
A5
A7
2,6 (0,10)
4,6 (0,18)
(Working str.)
(Total str.)
ØA2
ØA8
Port Functions:
P = Pressure
T = Tank
A+B = User
DIRECTIONAL CONTROL VALVES - 4D01
DC-10
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
1.97
Ø0.21
0.87
Ø0.35
Ø5.3
50.0
22.0
Ø9.0
Dimensions
mm
in
A3
A2
A4
A1
B7
B6
B8
Dimensions
B3
B2
B1
B5
B4
mm
in
B9
B10
181.0
135.5
90.5
40.0
17.0
40.5
45.0
77.0
31.0
32.5
3.56
5.33
7.13
1.77
1.59
0.68
1.57
3.03
1.22
1.28
B2
B8
B7
B6
B5
X
VELJAN HYDRAIR PVT. LTD
MADE IN INDIA
A
T
B
P
B4
B1
B3
Y
1/8" BSPP
B9
B10
A3
A2
ØA1
ØA4
Pilot Pressure
- w/o tank pressure
- 160 bar (2300 psi) tank pressure
Response Time
Pilot volume ( each side )
Functional Limits
at 350 bar (5000 psi)
Weight
1) depending on pilot pressure and pipe length
-operated one side
-operated both sides
-off
-on
1)
15.9 GPM ( 60 l/min ) ( for spools 01, 02, 03, 08, 09, 10, 11, 46, 51,
55, 56, 81, 91, OC
9.3 GPM ( 35 l/min ) ( for spools 07, 64, 65, 0Y, 0X )
2.6 GPM ( 10 l/min ) ( for spools 12, 52 )
5.1 lbs ( 2.33 Kg )
0.195 in . (3,2 cm )
3 3
20....200 ms
3.8 lbs ( 1.73 Kg )
20....200 ms
min. 4 bar (58 psi)
min. 6 bar (87 psi) / max. 12 bar (174 psi)
PNEUMATICALLY OPERATED VERSION
Port Functions:
P = Pressure
T = Tank
A+B = User
X+Y = Pilot Ports
DIRECTIONAL CONTROL VALVES - 4D01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-11
DC
DC
B8
B7
B6
B1
1/8" BSPP
B2
B5
X
VELJAN HYDRAIR PVT. LTD
MADE IN INDIA
A
T
B
P
B4
B3
Y
B9
B10
A3
A2
ØA4
ØA1
Pilot Pressure
Minimum
Maximum
Response Time
(at Pilot pressure of 50 bar (714 psi)
Pilot volume ( each side )
Functional Limits
at 350 bar (5000 psi)
Weight
1) depending on pilot pressure and pipe length
-operated one side
-operated both sides
-on
-off
1)
min. 145 psi ( 10 bar ) > tank pressure
max. 3000 psi ( 200 bar )
15.9 GPM ( 60 l/min ) ( for spools 01, 02, 03, 08, 09, 10, 11, 46, 51,
55, 56, 81, 91, OC
9.3 GPM ( 35 l/min ) (for spools 07, 64, 65, 0Y, 0X)
2.6 GPM ( 10 l/min ) (for spools 12, 52)
3
0.061 in . ( 1 cm )
3
50....100 ms
60....160 ms
3.6 lbs ( 1.64 Kg )
4.8 lbs ( 2.2 Kg )
Port Functions:
P = Pressure
T = Tank
A+B = User
X+Y = Pilot Ports
B7
B6
B8
Dimensions
B3
B2
B1
B5
B4
mm
in
B9
B10
161.0
125.5
80.5
77.0
30.0
17.0
45.0
40.5
31.0
32.5
4.94
6.34
3.17
0.68
1.18
3.03
1.77
1.59
1.22
1.28
Ø5.3
50.0
22.0
Ø9.0
1.97
Ø0.21
0.87
Ø0.35
Dimensions
mm
in
A3
A2
A4
A1
HYDRAULICALLY OPERATED VERSION
DIRECTIONAL CONTROL VALVES - 4D01
DC-12
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
Pressure shift sequence of spool stroke o to a or o to b.
Note:
1. The functional limit of soft shift version will be reduced by as much as 25 from standard, depending on the spool type.
2. The solenoid tube cartridges must remain filled with oil at all times. The tube cartridges are provided with venting screws (see above) to
remove air during initial start up. It is recommended to use a check valve (1...2 bar) (14-28 psi) in the tank line to prevent draining of oil
from solenoid tube cartridges especially when valve is mounted above the oil level.
Circuit Design
a
o
b
A B
P T
300 bar
0 bar
Example pressure unloading P to A :
300 bar (4285 psi) ; 15.9 gpm ( 60 l/min );
36cST; 120 °F ( 50°C )
V4D01-3-2-03-03-02-B-1- GOQ-G3
8.5 (0.33)
Venting
Venting
8.5 (0.33)
SOFT SHIFT VERSION, OPTION G3
VELJAN make CETOP 3 soft shift version ( option G3 ) has special solenoids that permit a multiple increase of
solenoid response time.
Option G3 provides:
- Reduced pressure shocks in venting operations.
- Reduced system noise during spool transition.
- Increased lifetime of the valve and system.
0 200 400 600 800 1000
100 (1428)
200 (2857)
300 (4285)
200 (2857)
100 (1428)
0
400
200
1000800
600
300 (4285)
Time t (ms)
Time t (ms)
Pressure bar (psi)
Pressure bar (psi)
0
1 1
0
t1
t2
Standard version
without option G3
Soft shift valve
with option G3
t3 t4
Spool stroke
Pressure change
Response times ( ms ) for 24 V DC Solenoid
Note:
Response time will be influenced by changes in viscosity, pressure or flow.
55...60
35...40
35...40
20...25
t1 t2
300...500
80...200
t3
t4
400...800
80...400
DIRECTIONAL CONTROL VALVES - 4D01
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC-13
DC
DC
B2
B1
Dimensions
mm
in
34.01.34
B1
B2
14.00.55
B2
B1
Dimensions
mm
in
B1
B2
1.18 30.0
10.00.39
½" Subplates
T
A
P
B
A1
A2
d4(Panel opening)
d1
d2
Dimensions
mm
51.0
53.02.08
A2
A1
2.0
in
1/4" & 3/8" Subplates
A
A2
( ) dimensions in brackets
are for 3/8" subplates
B
T
d1
d2
A1
P
d4 (Panel opening)
1.57(1.81)
1.73(1.81)
40(46)
44(46)
Dimensions
mm
A2
A1
in
40.5
21.5
30.2
46.0
12.7
0.75
5.1
7.5
31.75
25.9
15.5
31.0
51.0
1.59
0.85
1.19
1.81
0.50
0.03
0.20
0.30
1.25
1.02
0.61
1.22
2.0
A11
A13
A12
A10
A9
A8
A7
A2
A3
A5
A6
A4
Dimensions
in
A1
mm
Torque 8.3 Nm
0.8
Block mounting face
Flatness 0.01 mm / 100 mm length
Surface finish
For valves ordered without subplate,
mounting screws must be ordered separately.
M5 x 30, DIN 912; 10.9
4-Mounting screws
Order-No.
V700-70834-8
10-24 UNC-2A x 1 1/4" (SAE)
V358-10183-8
or
A7
A5
A6
A3
A4
M5 or 10-24 UNC-2A;
15 (0,59)dp.
A1
A13
A10
A9
P
A11
A12
A2
A8
A
T
B
MOUNTING CONFIGURATION (ACCORDING TO CETOP, ISO AND DIN)
Subplates
A
P
B
T
C1
C5
C2
C6
d3
C4
C3
C7
C9
C8
C2
C1
C5
C8
C7
d3
C6
P
C4
C3
T
A
B
105.0
Ø7.5
Ø12.0
Ø7.0
32.5
80.0
31.0
90.0
4.13
0.30
Ø0.47
Ø0.28
1.28
3.15
3.54
1.22
C6
C7
C3
C4
C5
C1
C2
C8
Dimensions
mm
in
C6
C7
C3
C4
C5
C1
C2
C8
C9
Dimensions
mm
in
Ø0.27
Ø0.47
3.54
2.91
1.27
3.54
2.91
Ø0.29
1.22
90.0
74.0
Ø7.0
32.5
Ø12.0
90.0
74.0
Ø7.5
31.0
10-24 UNC-2A
Thread for
Mounting Screws d3
10-24 UNC-2A
Ø26x1 dp.
VS26-32960VSS-B-06-G 136
VSS-P-08-G 135
VSS-B-08-G 136
VS26-32963
VS26-32961
3.7 lbs ( 1.7 kg )
Ø31x1 dp.
VSS-P-04-G 135
VSS-B-04-G 136
Model no.
d1 (A,B,P,T)
VS26-32962
Order no.
VS26-32959
3.1 lbs ( 1.4 kg )
Weight
Ø23x1 dp.
-
-
d2
M5
M5
M5
3.1 lbs ( 1.4 kg )
3.1 lbs ( 1.4 kg )
3.7 lbs ( 1.7 kg )
d4
Ø76(2.99)
Ø79(3.11)
Ø88(3.46)
Ø88(3.46)
Ø76(2.99)
G 3/8"
½" NPTF
G ½"
1/4" NPTF
G 1/4"
DIRECTIONAL CONTROL VALVES - 4D01
DC-14
DIRECTIONAL CONTROL VALVES - VEC/01/B/02-22/02 | Note : Product details are liable to change without notice
DC
DC
THIS P
AGE INTENTION
ALL
Y LEFT BLANK