Table of Contents


Importantbasicinformation3
Generalfunctiondescriptionofowmeter4
Generaldescription4
Flowmeterselection4
DeclarationofConformity4
Generalconditionsforinitialstart-up  4
Maximumoperatingpressure 5
StatementtoEU-Directive97/23/EG,Pressurizeddevices5
Flowmeterrange 6
Assemblyoftheowmeter  6
Cleaningandushingofpipelinesbeforeinitialstart-up  7
Filteringofliquid7
Preamplier7
Maintenance9
Sendingbackofrepairsandsampledevices9
TechnicalspecicationsVS002–VS410
FlowresponsecurvesVS002–VS4  11
DimensionsVS002–VS4 12
Dimensions,subplatesAP02-413
TechnicalspecicationsVS1014
FlowresponsecurvesVS10  14
DimensionsVS1015
Dimensions,subplateAPG1015
Typekey 16
Preamplier–blockwiringdiagram17
Outputsignalsonpreamplier  17
Plugassignment  18
Connectiondiagram  18
Pick-upsystemforhightemperaturesHT18
EC-DeclarationofConformity  21
Thecurrentpublicationofthisoperatinginstructionsupersedesallinformationfromprevious
publicationsVSEreservestherighttomakechangesandsubstitutionsVSEisnotliableforany
printingerrorsReproduction,includingexcerpts,ispermittedonlyafterwrittenapprovalby
VSEVSEreservestherighttomodifytechnicaldataatanytimeLastrevised:01/2012
3
Important basic information
Dear customer, dear user,
These installation and operating instructions should provide you with the information you need to properly install and commission
the ow meter. Installation, commissioning and testing are to be performed by trained and qualied personnel only. These operating
instructions must be read and applied carefully to ensure proper, trouble-free and safe operation of the ow meter. VSE is not liable
for any damage incurred resulting from not complying with the instructions in this operating instruction. It is not permitted in any
case to open the device.
These operating instructions for ow meters of the series VS in Standard-Version” from VSE must be stored, so that they can be read
by the group of authorized personnel at any time. Chapters may not be taken of these instructions at any time. A missing operating
instructions manual or missing pages must be replaced immediately. VSE can supply you with new instructions or you can download
the operating instructions from the internet (www.vse-ow.com). The operating instructions must be given to each subsequent user
of this product.
Legal information
This document is not managed by an updating service of VSE Volumentechnik GmbH.
Changes to this document may be made without notice.
VSE Volumentechnik GmbH does not provide any implicit guarantees of commercial qualities and suitability for a specic purpose.
If the device has been opened, modied or incorrectly connected to the electrical circuits, the guarantee of VSE Volumentechnik
GmbH for safe operation is void. VSE Volumentechnik GmbH is not liable in any way for personal injuries or damage to goods
resulting from improper installation or improper operating of the ow meter.
Operating manual–no.: E060014a (E)
4

 Istheowmeter?
 Istheuid?
 Istheuidoristherein?
 Whichdoesthesolidmatterpossessandcanit?
 Doestheuidhaveorother?
 Isitnecessarytoinstallapre-switched?
 Arethe andfreeofassemblyresiduessuchasswarf,weldchips?
 Istheandisitensuredthatcangetintothepipelinesystemfromthetank?
 Istheuidoftenchangedandis?
 Arethepipelinesandtheentiresystemcompletely?
 What isbeingused?
 Aretheuidandthecleaningagentcompatiblewiththe?
 Arethefortheuidundergoingmeasurement?
FlowmetersmadebyVSEVolumentechnikGmbHmeasurethevolumeow
ofliquidsaccordingtothetoothedwheelprincipleApairofveryprecisely
adjustedtoothedwheelsinthehousingconstitutesthemeterAsignalpick-
upsystemregistersmeterrotationfreeofcontactandtoothbytoothEach
toothisputoutasdigitalpulse
Thegapsintheteethofthemeterwheelsformmeterchambersintheareas,
inwhichtheyarecompletelyenclosedbythehousingwalls;thesecham-
bersdigitaliseliquidowdependingontheirchambervolume
Theliquidowquantitywithinonemeterrotationofatoothdivisionforms
thevolumemeasurementperpulse(V
m
)andisdenedincm
3
/pulseItiden-
tiestheconstructionalsizeofaowmeter
• General description
Pleasefollowallinstructionsinthisoperatingmanual;onlythisguarantees
atrouble-freeoperationoftheowmetersVSEisnotliableforanydama-
geensuingfromnon-followingoftheseinstructions
Openingthedevicesduringthetermofguaranteeisonlyauthorisedafter
consultationandapprovalofVSE
• Flow meter selection
         
          





• Declaration of Conformity
FlowmetersoftheVS”productlinearetestedfortheirelectromagnetic
compatibilityandinterferencetransmissionintermsofthelawonelectro-
magneticcompatibilityandcorrespondtothelegalprescriptionsenforced
byEMCdirectivesTheymaynotbeoperatedindependentlyandaretobe
connectedviacabletoapowersourceandsupplydigitalelectricsignals
for electronicevaluationAdeclarationofconformityissubmittedforall
owmeters,whichyoucanrequestifyourequire


   
      
        

Allowmetersaretestedaccordingtothevalid,legallyprescribedelectro-
magneticcompatibilitydirectivesEN55011andEN61000andpossess
the CE-certication The EC-declaration of conformity is the CE-label
attachedtoallowmeters
• General conditions for initial start-up
Beforeassemblyandbeforeinitialstart-up,youhavetonotethefollowing
propertiesandaspectsofthecorrespondingcharacteristicsofyoursystem,
sothatatrouble-freeandsafeoperationispossible
• General function description of ow meter
5

 Isthelowerthanthemaxpermittedoperatingpressureoftheowmeter?
 Isthe(onowmeter)belowthemaxpermittedfallofpressure?
 Doesanexcessivelyoccurontheowmeteratmaxow(egwithhigherviscosity)?
 Doestheowrangeoftheowmeter(dependingonviscosity)correspondtothe?
 Notethatowrangedecreasesthe!
 Doesthetemperaturerangeoftheowmetercorrespondtotheofthemedium?
 Istheofthepipelinelargeenoughandarethefallsinpressureinthesystemnotexcessive?
 Isthe(supplyandreverseow)correctlyconnectedandleak-proof?
 Hasthesufcientpowertooperatethesystem?
 AblockingowmetercanstopthewholeowIsaprovidedinthesystem?
• Maximum operating pressure
Beforeassemblingtheowmeter,youhaveto testthatthemax opera-
tingpressureofthesystemdoesnotexceedthemaxpermittedoperating
pressureoftheowmeterMeanwhile,observethetoppressuresthatcan
occur,whenoperatingthesystem

 Haveyouselectedtheoptimalowmeterandisthisequippedwiththe?
 Doestheoftheowmetercorrespondtotheprovidedvoltage?
 Isthepowersupplyvoltagesuppliedbythemainsorevaluationdevicesufciently?
 Doestheofthepowersupplyvoltagecorrespondtotherequiredpoweroutput?
 Hastheelectricconnectionbeeninstalledbasedontheenclosed?
 IsthecorrectlyconnectedonbothsidesontheearthconductorPE?
 IsthereabetweentheearthconductorconnectionPEontheowmeterandtheearthconductorPEontheevaluation
device?
 Doesacorrectingleadhavetobelaidtoeliminatethebetweentheowmeterandtheevaluationdevice?
 Istheowmeterconnectedrmlytothe(egviathepipelines)?
 IsthemeteroftheowmeterconstructedtobetotheearthconductorPE(egconnectionviahoses)?Ifthisisthecase,themeter
hastobeconnectedwiththeearthconductorPE!
 Is there a  of the cable protective shielding (earthconductor PE) via the housing, of the 4-pin round plug to the
housingoftheowmeter?
 Isthecablelaidfault-freeandtheinstallationsecuredfrominputof?
 Istheoftheconnectioncablermlyscrewedtogetherwiththeplugoftheowmeter?
 Arethewiresonthecorrectlyandproperlyconnected?
 Doestheentiresystemcorrespondtothedirectivesoftheelectromagneticcompatibilitylaws()?
 Havealllocalvalidregulations,,guidelinesandbackgroundconditionsofthe
beenmaintainedandobserved?
 SystemsthatcanleadtopersonalinjurythroughmalfunctionorfailurearetobeequippedwiththeThefunctioning
ofthesesafetydevicesistobecheckedatregularintervals
Thefollowingoperatingpressuresarepermitteddependingonowmeter
version:
 Flowmeteringreycastironversion p
max
=315bar/4500psi
Flowmeterinstainlesssteelversion p
max
=450bar/6500psi
Flowmeterinspecialversion p
max
=upto700bar/10100psi
Important:
Please consult VSE for all operating pressures > 450 bar / 6500 psi and for special versions.
VSEowmetersarepressurizeddevicesaccordingtoarticle1,paragraph
214ofabovementioneddirectiveThereforetheyaresubjecttotheregu-
lationstothisdirective
Accordingtoarticle3,paragraph14,VSEowmetershavetoconform
withthetechnicalrequirementsoftheguidelineTheuidstobemeasured
are belonging in most of all cases to the class 2, dened in article 9,
paragraph22VSEowmetersdonotreachthelimitvaluesasdened
inarticle3,paragraph11ThetechnicalrequirementsforVSEowmeters
therefore are limited to the parts indicated in article 3, paragraph 3 It
meansthedeviceshavetobedesignedandmanufacturedinconformity
withacknowledgedengineering,suchaspracticedinoneofthemember
statesThisisherewithconrmedBesidethis,theparagraphdeclaresthat
thesedevicesmustnothaveaCE-markingaccordingtoDirective97/23/
EGThereforewedonotissuedeclarationsofCEandourproductsarenot
labelledaccto97/23/EG
• Statement to EU-Directive 97/23/EG, Pressurized devices
6
• Assembly of the ow meter
Theowmetershouldbemountedonaneasilyaccessiblelocation,sothat
dismantlingforcleaningthemeterpresentsnoproblemSinceowmeters
canworkinanyinstallationpositionandowdirection,youcanmountit
on anylocation of your system that youwish Takecarewhen installing
theowmeterthatalwaysliquidremainsintheowmeterevenatsystem
standstill and that it can never run emptyThe outow ofthe owmeter
shouldthereforealwaysshowacertainbackpressureIncriticalcasesor
whenthepipelineisatstandstillorstandbyandcanrunempty,werecom-
mendinstallinganextranon-returnvalveintheoutowline
Flowmetersofthe“VS”productlinecanbemounteddirectlyontoablock
orintothepipelineusingfourscrewsAlwaysselectlargecrosssections
forthehydraulicsupplyandreturnowrespectivelyfortheentirepipeline
system(ifpossible)Thislowersthefallinpressureandtheowrateinthe
totalsystem
Important:
Make sure that the specied maximum permitted operating pressure of the ow meter
cannot be exceeded, whatever the operating mode of the system. Note the ow meter
range that is dependent on the viscosity of the uid to be measured.
Important:
Make sure that the ow meter is always completely lled both in inow and outow and that
the outow has a little back pressure. This prevents the meter being damaged by a sudden
and steep increase of ow and at the same time improves measurement accuracy.
Fig. 1: Flow meter installation with non-return valve
 
VS002;VS004;VS01;VS02 40Nm
VS04;VS1;VS2 70Nm
VS4 120Nm
VS10 280Nm
VSEsuppliessubplates forallowmetersof the VS” product line; they
havevariouspipethreadsandsideorrearsideconnection(seesubplates
datasheet)Dependingontheprovidedconditions,theinstalledpipeline,
thepipecrosssectionorpipethread,theoperatorcanchoosethesuitable
subplateandincorporatethisintothesystemormachinewithoutadditional
reductions
TheowmeterisscrewedontotheblockorsubplatewithfourDIN912
cheeseheadscrewsThescrewsaretobeevenlypre-tensedcrosswisewith
thefollowingtorques
When changing the fastening screws you must take great care that the
screwsareofpropertyclass109and129

The ow meter is directly mounted onto a subplate or manifold, extra
components are not needed The block contains the hydraulic supply
and outowof theowmeter andthexingboreholes(seeow meter
dimensionsheet)

Please note the special instructions for mounting sizes VS 4 and VS 10
(see appendix)
• Flow meter range
Theowmeterrangespeciedintheowmeterdatasheet(Q
min
-Q
max
)
referstothetestinguidhydraulicoil“withaviscosityof21mm
2
/sata
temperatureof20°CForthisowmeterrange,VSEspeciesmeasurement
accuracyofupto03%ofthemeasurementvalueandarepetitionaccu-
racyof005%
Foruids oflowerviscosity(< 21mm
2
/s)measurementaccuracydeteri-
orates, while for uids of higher viscosity (> 21 mm
2
/s) it can improve
Alsonote,however,thattheowmeterrangeisrestrictedincaseofhigher
viscosity(seeowmeterdatasheet)
Non-returnvalve
Flowmeter
Tank
7
• Filtering of liquid
Stronglycontaminateduidorextraneousmaterialintheuidcanblock,
damageorevendestroytheowmeterAlwaysinstallasufcientlylarge
lterforthesecasesinfrontoftheowmetertopreventdamageTheneces-
sarylteringdependsonsize,bearingsystemandversionofowmeter
Important:
Please ush out the pipe lines and the tank thoroughly, to prevent contamination with
the ow meter.
• Preamplier
The preamplier for the standard version is short-circuit-proof, reverse-
polarity-proofandprocessesthesignalsofthescansensorsAhighlevelof
interferenceprotectionisachievedthroughthepush-pulloutputstagesof
thepreamplierYoucaneasilyconnectevaluationdeviceswithbothPNP
andNPNinputstotheoutputsThetwo-channeloutputofdigitalsignals
enablesahighermeasurementresolutionandalsoadirectionrecognition
oftheow
Important:
When mounting the ow meter, you must take great care that the seals are not damaged
and correctly placed in the hydraulic connections of the ow meter. Wrongly installed or
damaged seals lead to leakage and to an leaky system, which may have dire consequences.
Please make sure that ow meters with EPDM seals do not come into contact with oil and
greases on a mineral oil basis. These uids can decompose the seals.
The yellow plastic plugs in the hydraulic connections of the ow meter protect the meter
against dirt and contamination during storage and shipping. Before mounting the ow meter
you have to remove these plugs so that in- and outow is free and open.
• Cleaning and ushing of pipe lines before initial start-up
Before initial start-up of the ow meter, you must ush and clean the
whole system Contaminateduids can affect the correct functionof the
owmeterorseriouslydamagethemeter
After preparingandconnecting upthesystempipes, youmustrstcare-
fullyushandcleanthewholepipelinesystemandthetankTodothis,
you have to mount a diversion plate onto the block or subplate instead
of the ow meter, so that the uid can ow through the diversion plate
andallextraneousmaterial(egswarf,metalchips,etc)canbeushed
outwithoutobstructionUseauidascleansingagent,whichiscompati-
blewiththeuidbeingusedlaterandwhichdoesnotcauseundesirable
reactionsYoucanconsultthesuppliersandmanufacturersoftheuidor
contactVSEforthecorrespondinginformationVSEsuppliesbypass-plates
thecorrespondingforallVSowmetersizes
Flowmetersaremeasurementpick-upsystemsmadewithhigh-levelpreci-
sionTheyhaveamechanicalmeterconsistingoftwotoothedwheelsand
whichisadaptedtothehousingwithnarrowslotsEventhetiniestdamage
tothetoothed wheels andbearingscan causeameasurement errorSo
alwaysmakesurethatnoextraneousmaterialgetsintothemeterandthat
theuidowingthroughisalwaysfreefromdirtandcontamination
Afterthesystemhasbeencarefullyushedoutandnoextraneousmaterial
isinthepipeline,youcanmounttheowmeterandcommencetheinitial
start-up
 
VS002/004/01 10µm
VS02/04 20µm
VS1/2/4/10 50µm

For information on lter size for ow meters with plain bearings, in spe-
cial version, or with specially adjusted meter tolerances, please consult
VSE GmbH.
Important:
A blocking ow meter can stop the whole ow. You have to provide a control
valve / bypass for the system.
8
PowersupplyvoltageinvoltagerangeU
b
=10…28VDCYoucanope-
ratethepreamplierwithanyvoltageinthisvoltagerangeU
b
,butmake
surethatthesignalvoltageisalwaysadjustedtothepowersupplyvoltage
andthattheoutputsignalhasasignallevelofU
sig
=U
b
–1V
Permittedforthepowersupplyisasteadydirectvoltagewithamaximum
residualrippleof±15%
Important:
Please make sure that no extra inductive elements are connected in the power supply of
the ow meter, such as contactors, relays, valves etc. These components are potential
sources of interference (especially if the inductive elements are not provided with an
adequate protective circuit), generate high interference pulses, when switched and can
interfere with the functioning of the ow meter, although this complies with the electro-
magnetic compatibility directives.
Fig. 2: Signal output of preamplier
Theno-loadcurrentreceptionofthepreamplierdependsoneachpower
supplyvoltage
PowersupplyvoltageU
b
=12VDC I
0max12
=25mA
PowersupplyvoltageU
b
=24VDC I
0max24
=40mA
Maxcurrentperchannel I
Kmax
=20mA
(the current I
K
is dependent on the input impedance of the evaluation
electronics)
Totalcurrentreception(at12VDC) I
0tot
=65mA
I
0tot
=I
0max12
+(2xI
Kmax
) P
max
=078W
Totalcurrentreception(at24VDC) I
0tot
=80mA
I
0tot
=I
0max24
+(2xI
Kmax
) P
max
=192W
Theelectricconnectionoftheowmeterisperformedviathe4-pinround
plug located on the preamplier housing The connection cable plug is
pluggedintotheplugconnectionoftheowmeterandscrewedtogether
Signal from channel 1
Signal from channel 2
2nd flow direction (from B A)
1st flow direction (from A B)
Decreasing flow = lowering of sensor frequency Increasing flow = raising of sensor frequency
Q = 0 ml/min
t
Change in the
direction of flow
t
1
2
3
4
1* -1
-2
-3
-4
-1*
one volume measurement
1 V
m
one chamber volume
one tooth + one tooth gap
one movement of tooth = 360°
2* -2*
t
Q
1st Flow direction
2nd Flow direction
9
• Sending back of repairs and sample devices
Itisimperativethatyouencloseanexactdescriptionofthecomplaint,ob-
jection or fault, when returning the device so as to ensure a rapid and
economic repair ofthe owmetersandothercomponentsFurthermore,
youmustincludeasecuritysheet,whichinformsunambiguously,whichuid
wasrunwiththeowmeterandhowdangerousthisuidis
Themaintenanceoflegalregulationsasregardsworksafety,suchaswork-
placeregulations,accidentpreventionregulations,stipulationsonenviron-
mentalprotection,wastedisposalandthewatermanagementlaw,obliges
industrialcorporationstoprotecttheiremployeesandotherpersonsand
environmentagainstharmfuleffects,whenhandlinghazardousmaterials
If further safetyprecautions are still necessary despite careful emptying
andcleaningoftheowmeter,informationonthisisimperativeandmust
beincludedwiththereturneddespatch
When returning owmeters to VSEVolumentechnik GmbH, please note
thatinspectionandrepairwillonlybeperformedifthe
oftheutilisedmedium isenclosedandtheowmeterscom-
pletely cleaned and ushed This protects our employees and simplies
ourwork


Important:
If there are potential differences between the preamplier housing and the
earth conductor PE of the evaluating electronics, you have to lay a correcting earth
(see connection diagram).
• Maintenance
Themaximumcablelengthbetweenowmeterandtheevaluationelectro-
nicsisapprox120mWithextensivecablelengths(asofapprox40m)
youmusttakecarethattheconnectingcableislaidinaninterference-free
environment,thattheshieldingisconnectedonbothsidesoftheearthcon-
ductorPEandthatthereisnopotentialdifferencebetweenthetwoearth
conductorconnections
Important:
Only use well-shielded cables for the connection cable, with a wire cross section of
≥ 4 x 0.25 mm
2
. Please make sure that the housing of the round plug is metallic, that it has
a connection for the shielding and that the potential of the earth conductor PE is connected
to the cable shielding and the housing of the preamplier.
TheshieldingoftheconnectioncableisplacedonbothsidesTheearth
conductorPEisconnectedviatheshieldingfromtheevaluationelectronics
tothepreamplierhousingandthemeterThecableshieldingshouldal-
waysbelaidcontinuouslyasfarastheowmeterandnotinterruptedin
crossconnectorsorbranchsocketsLaytheconnectioncableasdirectly
aspossiblefromtheevaluatingdevicetotheowmeter,sinceinterruptions
arealwaysapotentialsourceoferror
TheowmetermustbeconnectedelectricallywiththeearthconductorPE
Thisisnormallysecuredbytheearthedpipelines
Working life is dependent on operating conditions and thus the specic properties of the
devices, limited through wear, corrosion, deposits or age.
The operator is responsible for regular control, maintenance and recalibration. Any
indication of a malfunction or damage prohibits any further use. On request, we can supply
you with a borrowed device for the duration of repair or overhauling.
We advise to a yearly control and recalibration.
Fig. 3: M12 plug connector installed in the preamplier housing of the
ow meter
metalhousingconnected
withtheshieldingandthe
earthconductorPE

Pin4
digitalsignal
2channel
Pin1
powersupply
U
b
=10–28VDC
Pin2
digitalsignal
1channel
Pin3
powersupply
GND(-U
b
=0V)
10
• Technical specications VS 0.02 – VS 4
 








VS002 0002…2 1667…166667 002 50000
VS004 0004…4 1667…166667 004 25000
VS01 001…10 1667…166667 01 10000
VS02 002…18 1667…150000 02 5000
VS04 003…40 1250…166667 04 2500
VS1 005…80 0833…133333 1 1000
VS2 01…120 0833…100000 2 500
VS4 10…250 4,167…104167 4 250
 :upto03%ofmeasurementvalue(withviscosity>20mm
2
/s)
 :±005%underthesameoperatingconditions
 :CastironEN-GJS-400-15(EN1563)or
Stainlesssteel14305
 :Ballbearingsorsteelplainbearings(medium-dependent)
 :FPM(standard),NBR,PTFEorEPDM
 :CastironEN-GJS-400-15(EN1563)315bar/4500psi
Stainlesssteel14305 450bar/6500psi
 :–40…+120°C(–40°F…248°F)
 :–20…+50°C(–4°F…122°F)
 :1…100000mm
2
/s
 :any
 :any
 :max72db(A)
 :10to28volts/DC
 :2xpush-pulloutputstages
reverse-polarity-proof,short-circuit-proof
lowsignal:0=GND;highsignal:1=U
b
-1
I
max
=80mA(at24V)
P
max
=192W(at24V)
 :90°±30°max
 :1/1±15°max
 :Aluminium
 :IP65
11
• Flow response curves VS 0.02 – VS 4
.
.
.
.
.
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
FlowQ
Flowresistance∆p
 
 
 
 
12
• Dimensions VS 0.02 – VS 4


 




 100 80 91 M6 120 9 114 58 70 40 20 11x2 28 34
 100 80 92 M6 11 5 9 115 59 70 40 20 11x2 28 34
 100 80 94 M6 9 9 117 61 70 40 20 11x2 28 34
 100 80 94 M6 95 9 117 61 70 40 20 11x2 30 37
 115 90 965 M8 11 5 16 120 635 80 38 34 1796x262 40 50
130 100 101 M8 12 5 16 124 68 84 72 34 1796x262 53 68
130 100 118 M8 15 16 141 85 84 72 34 1796x262 67 84
180 140 145 M12 20 30 168 110 46 95 45 3617x262 147 184

Dimensions in mm
ViewX
ViewX
Stainlesssteelversion
Connectiondiagram
Housingwithoutmillededge
Castironversion
Connectiondiagram
O-ring
Castironversion
Plugpositionfor
VS002toVS04andVS4
Earth
Centringborehole
Centringborehole
PlugpositionforVS1/VS2
M12x1
M12x1
13




 






G1/4“
G3/8“
G1/2“
35
20
80 90 40 70
26
100 M 6/12 18
23 30
28
38

G1/2“ 35 28
90 100 38 80
46
115 M8/15 27
G3/4“ 40 33 52
G1/2“ 35 28
100 110 72 84
46
130 M8/15 36G3/4“ 40 33 52
G1 55 41 55
G11/4“ 70 51
120
130 100
110 60
M8/15
7 4
*G11/2 70
56
120
72
G11/2“ 80 140 110 180 120
• Dimensions, subplates AP. 02 - 4


only for AP. 4 U...
Flowmeter
Subplate
Flowmeter
Subplate
14
• Technical specications VS 10
 :upto03%ofmeasurementvalue(withviscosity>20mm
2
/s)
 :±005%underthesameoperatingconditions
 :CastironEN-GJS-600-3(EN1563)
 :Ballbearingsorsteelplainbearings(medium-dependent)
 :70kgwithoutsubplate
 :FPM(standard),NBR,PTFEorEPDM
 :420bar/6000psi
 :-40…120°C(-4F…248°F)
 :-20…+50°C(-4°F…122°F)
 :5…100000mm
2
/s
 :any
 :any
 :db(A)
 :10to28volts/DC
 :0…2625Hz
 :2xpush-pulloutputstages
reverse-polarity-proof,short-circuit-proof
lowsignal:0=GND;highsignal:1=U
b
-1
I
max
=80mA(at24V)
P
max
=192W(at24V)
 :90°±30°max
 :1/1±15°max
 :Aluminium
 :IP65
 








VS10 15…525 750…262500 3333 300
• Flow response curves VS 10
FlowQ
Flowresistance
Flowresistance∆p
15
• Dimensions VS 10
• Dimensions, subplate APG 10.


Dimensions in mm
Dimensions in mm
Weight70kg
ConnectionsurfaceVS10
View X
Weight21kg
Weight30kg
ConnectionsurfaceVS10
View X
View X
Barhandle
Liftingeyebolt
Liftingeyebolt
O-ring
Connectiondiagram
16
• Type key


Example:
Example:
17
• Preamplier-block wiring diagram
• Output signals on preamplier
 
Sensor 1
Sensor 2
Channel 1
Channel 2
0 Volts
+ Volts
Equipotential bonding
brown
white
blue
black
Evalution unit
signal transformation
amplification
push-pull
output stages



 

Gear rotation of one gear tooth pitch
3 impulse pro volume of one tooth pitch
Volume measurement cm /Imp
Flow direction 1
Flow direction 2
Channel 1
Channel 2
Impulse mark/space ratio
(adjust. at preamplifier)
Channel offset by
1/4 of tooth pitch (90°)
Upp
Meter rotation by one measuring wheel division
1 puls per throughput amount of liquid by one division
Volume measurement cm /pulse
Flow direction 1
Flow direction 2
Channel 1
Channel 2
Pulse-width repetition rate of one pulse
(adjusted to preamplifier)
Channel offset by
1/4 division (90°)
Upp
3
3
(10cm
3
)
18
• Plug assignment
• Connection diagram
Modicationofowdirectionindicator
(+after-/-after+)byinterchanging
channels
(channel1_channel2)
• Pick-up system for high temperatures HT
Formediumtemperatures>120°C,thehightemperature(HT)versionsby
VSEhavetobedeployedFlowmetersofstainlesssteelareusedexclusi-
velyinthiscase
Thesensororpick-upsystemconsistsofasensorunit,whichisscrewedinto
thecoveroftheowmeterandadownstreamamplierTheamplieris
connectedwiththeowmeterviaatemperature-stablecableandhasto
beinstalledoutsidethehightemperaturezoneTheambienttemperature
shouldbenomorethan50°Cinthisarea
The digital signals are emitted as PNP- or NPN-signals, depending on
amplierversion
Withextensivecablelengths,werecommendusingshieldedcablesanda
pull-down(PNPsignal)orpull-upimpedance(NPNsignal)

Pin2
digitalsignal
Pin3
powersupply
0V

Pin4
free
Pin1
powersupply
+U=10–30VDC
19

 -4C210°C
 1or2pickups
 magnetoresistive
 cablegland
 FPMorEPDM


O-ring
 
 U
b
=10…30VDC+/-10%
 I
b
=ca18mA(idlemotion,withoutlead)
 HighSign:U
S
=U
b
-1V;I
S
=25mAmax
 LowSign:U
S
=0V;I
S
=25mAmax
 4pinroundplugM12
 -20°C50°C
 IP64
 47…10KΩPNP-Version
 47…10KΩNPN-Version
   
 100 M6 11 5 ø9 59 70 40 20 22 11x2 33
 100 M6 9 ø9 61 70 40 20 22 11x2 33
 100 M6 95 ø9 61 70 40 20 22 11x2 36
 115 M8 11 5 ø16 635 80 38 34 22 18x262 49
 130 M8 12 5 ø16 68 84 72 34 22 18x262 67
 130 M8 15 ø16 85 84 72 34 22 18x262 83
 180 M12 20 ø30 110 46 95 45 12 3617x262 183
+U
0 V
1
2
3
442R
Pulse output NPN-version
R
L
R
L
+U
0 V
1
2
3
442R
Pulse output PNP-version
*only available as single-channel version
V
20

DistributioncableforconnectionoftwoHT-pick-upsonaVSE-connectingcable

Volts
Volts
Channel 1
Channel 1
Volts
Volts
Volts
Volts
21





Wir,
We,
Nous,
VSE Volumentechnik GmbH, Hönnestre 49, 58809 Neuenrade/Germany
erkläreninalleinigerVerantwortung,dassdieProdukte„Volumensensor“mitderTypenbezeichnung:
herebydeclareinoursoleresponsibility,thattheproduct“volumetricsensor“withthetypecodes:
déclaronsdenotreresponsabilité,queleproduitcapteurvolumétrictype:
VS *** ******-32N1*/*
VSI ***/* ******-32W1*/*
VHM *-*****/*-V*I*-*S**/N
Anstelle der Sterne sind Buchstaben und Ziffern eingesetzt, die den
Volumensensor kennzeichnen, welche aber keinen Einfluss auf die EMV
haben
Insteadofstarsthereareinsertlettersandnumbers,whichmarkedtheflow
meterbuthavenoinfluenceontheEMC
Deslettresetdeschiffres,symbolisantlecapteurvolumétrique,sontàmettre
enlieuetplacedesastérisquesIlsn`ontaucuneinfluencesurleCEM
aufdiesichdieseErklärungbezieht,mitdenfolgendenNormenodernormativenDokumentenübereinstimmt
whichisthesubjectofthisdeclaration,isinconformitywiththefollowingstandardornormativedocuments
auquelcettedeclarationserapporte,estconformeauxnormeouauxdocumentsnormatifssuivants
BestimmungenderRichtlinien
Termsofthedirective
Prescriptiondeladirective
Norm
Standard
Norme
2004/108/EWGElektromagnetischeVerträglichkeit
2004/108/EEC:Electromagneticcompatibility
2004/108/CEE:Compatibilitéélectromagnétique
EN61000-6-4:2005
EN61000-6-2:2005-2008
Qualitätsmanagementsystem:
Qualitymanagement:
DirectiondeQuali:
DINENISO9001:2008
QA-Nr:04100960054
Neuenrade,den07072006
OrtundDatumderAusstellung
Placeanddateofissue
Lieuetdatedétablissment

TechnischerLeiter
TechnicalDirector
DirecteurTechnique
• Declaration of Conformity Standard
22
Notes
23
Notes
24