FSC-FSB
SUCTION FILTERS
FSC
41
FSC
SUCTION FILTERS
Suction lter
FSC31 & FSC41
Cover & head: Aluminum alloy
Bowl: Polyamide
FSC71 & FSC81
Cover & housing: Aluminum
FSC51 & FSC61
Housing: Steel
Cover: Aluminum
Shut-o valve: Polyamide
Seals: NBR Nitrile
(FKM uoroelastomer on request)
Indicator housing: Brass
Collapse, dierential for the lter element: 100 kPa (1 bar)
Qmax 500 l/min
From -25° to +110° C
DESCRIPTION
MATERIALS
PRESSURE
FLOW RATE
WORKING TEMPERATURE
Full with uids: HH-HL-HM-HV-HTG
(according to ISO 6743/4)
For uids dierent than the above mentioned,
please contact our Customer Service.
Is this datasheet the latest release? Please check on our website
COMPATIBILITY (ISO 2943)
HYDRAULIC DIAGRAM
42
FILTER HOUSING FILTER ELEMENT CLOGGING INDICATOR ACCESSORIES
B S C F W E S C X
SPARE PARTS
FSC
SUCTION FILTERS
F S C COMPLETE FILTER FAMILY FILTER ELEMENT FAMILY E S C
SIZE & LENGTH
31 41 51 61 71 81
SIZE & LENGTH
PORT TYPE
B = BSP thread
B B - - - -
F = SAE ange 3000 psi - F F F F F
PORT SIZE
10 = 1" 1/4
10 - - - - -
12 = 1" 1/2 (B12 only) - 12 - - - -
16 = 2" (F16 only) - 16 - - - -
20 = 2" 1/2 (F20 only) - 20 - - - -
24 = 3" - - 24 - 24 -
32 = 4" - - - 32 - 32
W
BYPASS VALVE
W = no bypass
W W W W W W
SEALS
SEALS
N = NBR Nitrile (only for complete lter)
N N N N N N
F = FKM Fluoroelastomer (only for complete lter) F F F F F F
X = not applicable (only for lter element) X X X X X X
G = treatment for water-glycol (for lter and element) G G G G G G
FormulaUFI MEDIA
FormulaUFI MEDIA
ME = FormulaUFI.WEB 60 µm
ME ME ME ME ME ME
MF = FormulaUFI.WEB 90 µm MF MF MF MF MF MF
MG = FormulaUFI.WEB 250 µm MG MG MG MG MG MG
CLOGGING INDICATOR
01 = 1/8" port, plugged
- - - - - 01
04 = nr.2 x 1/8" seats, plugged 04 04 04 04 04 -
10 = vacuum gauge, rear connection 10 10 10 10 10 10
91 = SPDT, vacuum switch 91 91 91 91 91 91
ACCESSORI / ACCESSORIES
W = without
W W W W W W
M = magnetic core - M M M M M
ACCESSORI / ACCESSORIES
W = without
W W W W W W
S = safety switch - S S S S S
ORDERING AND OPTION CHART
Ø180
Ø210
R
H3
D1
E
12
M12
30°
30°
Ø181
Ø151
30°
30°
R
H1
H3
E
D1
1/8"
H2 max.
12
H2 min.
H2 max.
FSC 51
TANK MOUNTING PATTERN
TANK MOUNTING PATTERN
FSC 61
LOOSE FLANGE
(TO BE WELDED)
H1
H2 min.
1/8"
LOOSE FLANGE
(TO BE WELDED)
M12
FSC Heavy - 30%
Ø180
Ø210
R
H3
D1
E
12
M12
30°
30°
Ø181
Ø151
30°
30°
R
H1
H3
E
D1
1/8"
H2 max.
12
H2 min.
H2 max.
FSC 51
TANK MOUNTING PATTERN
TANK MOUNTING PATTERN
FSC 61
LOOSE FLANGE
(TO BE WELDED)
H1
H2 min.
1/8"
LOOSE FLANGE
(TO BE WELDED)
M12
FSC Heavy - 30%
43
NBR FKM
NBR FKM
FSC31
521.0088.2 521.0090.2
FSC41
521.0023.2 521.0091.2
FSC51
521.0089.2 521.0092.2
NBR FKM
NBR FKM
FSC61
521.0024.2 521.0093.2
FSC71
521.0097.2 521.0098.2
FSC81
521.0099.2 521.0100.2
SPARE SEAL KIT
INSTALLATION DRAWING
D1 D2 E H1 H2 H3 R kg
FSC31
1"1/4 - - 42 80 275 250 22 1,6
FSC41
1"1/2 - 2" - "1/2 - - 66 120 322 300 32 3,0
FSC51
3" 210 110 95 174 ÷ 355 480 500 32 13,0
FSC61
4" 242 130 122 250 ÷ 405 470 500 32 16,0
FSC71
3" 220 110 80 265 348,5 250 10 5,5
FSC81
4" 242 110 80 264 348,5 250 10 6,0
FILTER HOUSING
FSC51 FSC61
FSC 31
H1
6
68
D1
H3
H2
R
55
Ø88
M8
45°
45°
Ø126
110
1/8"
TANK MOUNTING PATTERN
FSC 41
TANK MOUNTING PATTERN
R
12
175
75
85
H1
H2
H3
D1
M10
104
Ø132
146
1/8"
Ø180
30°
30°
Ø151
M12
R
123
H1
H3
H2
60
D1
D2
E
1/8"
FSC 71
TANK MOUNTING PATTERN
FSC 81
TANK MOUNTING PATTERN
R
H1 123
60
H2
H3
D2
D1
E
1/8"
Ø210
30°
30°
M12
Ø181
FSC - 30%
44
FSC
SUCTION FILTERS
INSTALLATION DRAWING
D1 D2 E H1 H2 H3 R kg
FSC31
1"1/4 - - 42 80 275 250 22 1,6
FSC41
1"1/2 - 2" - "1/2 - - 66 120 322 300 32 3,0
FSC51
3" 210 110 95 174 ÷ 355 480 500 32 13,0
FSC61
4" 242 130 122 250 ÷ 405 470 500 32 16,0
FSC71
3" 220 110 80 265 348,5 250 10 5,5
FSC81
4" 242 110 80 264 348,5 250 10 6,0
FILTER HOUSING
45
FILTER ELEMENT
AREA (cm
2
)
A B C Kg Media M+
ESC31
29,5 70 163 0,25 1.600
ESC41
65 99 198 0,50 1.845
ESC51
65 99 375 0,90 3.545
ESC61
93 136 375 1,50 5.065
ESC71
77 120 196 0,80 2.400
ESC81
93 136 196 0,90 2.600
A
B
C
MAINTENANCE
1) Stop the system and verify there is no pressure in the lter.
2) Unscrew the threaded pin (1) to close the bulkhead (2) on the
bottom of lter housing and to prevent oil leakage from the
system.
3) Collect the oil inside the lter with a suitable container.
4) FSC31-FSC41-FSC51 Loosen the nuts/screws (3) on the
cover (4). N.B. it is not necessary to disassemble the nuts, use
the slots on the cover. FSC61-71-81: Unscrew the screws (3).
5) FSC31-FSC41-FSC51 Turn the cover (4) clockwise and remove
it. FSC61-71-81: remove the cover (4).
6) Remove the dirty lter element (2).
N.B. The used lter elements and oil dirty lter parts are
classied “Dangerous waste material” and must be disposed of
according to the local laws, by authorised Companies.
7) Check the lter element part number on the lter label or in the
ordering and option chart.
Use only original spare parts.
8) Insert the clean element (5) in the housing (6) resting on the
bottom gasket (7).
Lubricate the new element o-ring gasket (3) with oil.
9) Check the correct positioning and condition of the gasket (8)
and o-ring (9) respectively assembled on the cover (4) and
housing (6). Lubricate with oil if necessary. If damaged, check
the catalogue or call the customer care service.
Insert the clean element into its seat with care.
10) Position the cover (4) and tighten the screws/nuts (3) until it
stops.
11) Screw the threaded pin (1) up to the stop on the cover (4). This
opens the bulkhead (2) on the bottom and allows the oil inlet
from the tank. N.B. The o-Ring (10) ensures the seal between
the pin and the cover.
Accessories:
Safety switch. The threaded pin (1) must be completely screwed to
close the contact of microswitch (11). If the pin is unscrewed, the
microswitch opens. If damaged, check the catalogue or call the
customer care service.
Clogging indicator. If damaged, unscrew and replace it (check the part
number in the ordering and option chart). Apply a thread-sealing and
screw until tight.
N.B. an over-tightening can damage the thread.
111
9
4
10
3
5
2
6
7
8
l/min
ESC 51
4
Δp (kPa)
1
2
3
0
600
100 200 300 400 500
l/min
ESC 61
4
Δp (kPa)
1
2
3
0
600100 200 300 400 500
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 51 - 61
3"3" 4"4"
SUCTION FILTERS
Recommended
Range
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”
0,1< v < 1 m/s
SC
HEAVY
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
l/min
ESC 51
4
Δp (kPa)
1
2
3
0
600100 200 300 400 500
l/min
ESC 61
4
Δp (kPa)
1
2
3
0
600100 200 300 400 500
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 51 - 61
3"3" 4"4"
SUCTION FILTERS
Recommended
Range
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”
0,1< v < 1 m/s
SC
HEAVY
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
l/min
ESC 51
4
Δp (kPa)
1
2
3
0
600100 200 300 400 500
l/min
ESC 61
4
Δp (kPa)
1
2
3
0
600100 200 300 400 500
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 51 - 61
3"3" 4"4"
SUCTION FILTERS
Recommended
Range
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”
0,1< v < 1 m/s
SC
HEAVY
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
SUCT ION FI L T ERS
l/min
ESC 31
4
Δ
p (kPa)
1
2
3
0
15025 50 75 100 125
l/min
ESC 41
4
1
2
3
0
30050 100 150 200 250
Δp (kPa)
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
Δp (kPa)
l/min
4
1
2
3
0
600100 200 300 400 500
ESC 81
Δp (kPa)
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 71 - 81
3"3" 4"4"
l/min
FSC31 - 41
0
300
4
Δp (kPa)
50 100 150 200 250
1
2
3
111/41/4
111/2
1/2
2
21/21/2
2
2
SUCTION FILTERS
Recommended
Range
2” 1/2
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
SC
STANDARD
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
p (kPa)
SUCT ION FI L T ERS
l/min
ESC 31
4
Δp (kPa)
1
2
3
0
15025 50 75 100 125
l/min
ESC 41
4
1
2
3
0
30050 100 150 200 250
Δp (kPa)
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
Δp (kPa)
l/min
4
1
2
3
0
600100 200 300 400 500
ESC 81
Δp (kPa)
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 71 - 81
3"3" 4"4"
l/min
FSC31 - 41
0
300
4
Δp (kPa)
50 100 150 200 250
1
2
3
111/41/4
111/2
1/2
2
21/21/2
2
2
SUCTION FILTERS
Recommended
Range
2” 1/2
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
SC
STANDARD
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
SUCT ION FI L T ERS
l/min
ESC 31
4
Δp (kPa)
1
2
3
0
15025 50 75 100 125
l/min
ESC 41
4
1
2
3
0
30050 100 150 200 250
Δp (kPa)
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
Δp (kPa)
l/min
4
1
2
3
0
600100 200 300 400 500
ESC 81
Δp (kPa)
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 71 - 81
3"3" 4"4"
l/min
FSC31 - 41
0
300
4
Δp (kPa)
50 100 150 200 250
1
2
3
111/41/4
111/2
1/2
2
21/21/2
2
2
SUCTION FILTERS
Recommended
Range
2” 1/2
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
SC
STANDARD
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
SUCT ION FI L T ERS
l/min
ESC 31
4
Δp (kPa)
1
2
3
0
15025 50 75 100 125
l/min
ESC 41
4
1
2
3
0
30050 100 150 200 250
Δp (kPa)
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
Δp (kPa)
l/min
4
1
2
3
0
600100 200 300 400 500
ESC 81
Δp (kPa)
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 71 - 81
3"3" 4"4"
l/min
FSC31 - 41
0
300
4
Δp (kPa)
50 100 150 200 250
1
2
3
111/41/4
1
11/21/2
2
21/21/2
2
2
SUCTION FILTERS
Recommended
Range
2” 1/2
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
SC
STANDARD
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
SUCT ION FI L T ERS
l/min
ESC 31
4
Δp (kPa)
1
2
3
0
15025 50 75 100 125
l/min
ESC 41
4
1
2
3
0
30050 100 150 200 250
Δp (kPa)
l/min
4
1
2
3
0
30050 100 150 200 250
ESC 71
Δp (kPa)
l/min
4
1
2
3
0
600100 200 300 400 500
ESC 81
Δp (kPa)
l/min
0
600
4
Δp (kPa)
100 200 300 400 500
1
2
3
FSC 71 - 81
3"3" 4"4"
l/min
FSC31 - 41
0
300
4
Δp (kPa)
50 100 150 200 250
1
2
3
111/41/4
111/2
1/2
2
21/21/2
2
2
SUCTION FILTERS
Recommended
Range
2” 1/2
600
550
500
450
400
350
300
250
200
150
100
50
0
4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
SC
STANDARD
SERIES
FSC-FSB
FLOW RATE [l/min]
PORT SIZE
46
All the curves have been obtained with mineral oil having a kinematic viscosity
30 cSt and specic gravity 0,86 kg/dm
3
; for uids with dierent features, please
consider the factors described in the rst part of this catalogue. All the curves
are obtained from test done at the UFI FILTERS HYDRAULICS Laboratory,
according to the specication ISO 3968. In case of discrepancy, please check the
contamination level, viscosity and features of the uid in use.
PRESSURE DROP CURVES (ΔP)
N.B.
The Pressure Drop (Δp) must be lower than 3 kPa (0,03 bar).
FSC
SUCTION FILTERS
FILTER HOUSING PRESSURE DROP
(mainly depending on the port size)
CLEAN FILTER ELEMENT PRESSURE DROP
(pressure drop values of the elements by ME - MF - MG media are very similar)