153
MAINTENANCE
B
A
C
FILTER ELEMENT
AREA (cm
2
)
A B* C Kg Media
F+
Media
C+
Media
M+
ERA11
38 13 50 0,05 270 345 200
ERA21
52 24 70 0,10 310 380 240
ERA31
70 28 85 0,20 620 990 460
ERA32
70 28 130 0,25 1.000 1.600 740
ERA33
70 40 210 0,40 1.660 2.670 1.220
ERA41
99 40 211 0,75 3.800 4.280 1.900
ERA42
99 40 250 0,90 4.550 5.100 2.270
ERA51
130 51 140 1,00 4.140 4.360 1.800
ERA5A
130 51 200 1,10 5.840 6.460 2.730
ERA52
130 63 200 1,35 5.840 6.460 2.700
ERA5B
130 63 200 1,45 7.070 7.070 2.700
ERA5C
130 63 232 1,50 7.280 7.600 3.040
ERA53
130 63 251 1,55 7.500 8.350 3.450
ERA5D
130 63 266 1,60 8.000 8.800 3.730
1) Stop the system and verify there is no pressure in the lter.
2) Loosen the screws (1) until the cover (2) is free to rotate clockwise.
3) Remove the cover (2) and the spring (3) below. N.B. Handle
with care the clogging indicator (7) when present.
4) Remove the dirty lter element (4) using its handle.
N.B. The exhausted lter elements and the oil dirty lter parts are
classied “Dangerous waste material” and must be disposed of
according to the local laws, by authorized Companies.
5) Check the lter element part number on the lter label or in the
ordering and option chart. Use only original spare parts.
6) Lubricate the element o-ring gasket (5) with oil.
7) Insert the clean element into its seat with care.
8) Re-assembly the spring (3).
9) Check the cover o-ring condition (6) and lubricate with oil.
If damaged, check the seal kit part number in the spare seal kit table
10) Re-assembly the cover (2) and tighten the screws (1)
Accessories:
Clogging indicator (7).
If damaged, unscrew and replace it (check the part number in the
ordering and option chart). Apply a thread-sealing and screw until
tight. N.B. overtightening can damage the thread.
* Connection dimension
1
7
6
4
2
5
3