ESA-FAM
SUCTION FILTERS
ESA
ESB
25
ESA-ESB
SUCTION FILTERS
Connector: Polyamide (Aluminum for ESA & ESB 51 - 52)
End cap: Polyamide (Zinc plated steel for ESA & ESB 51 - 52)
Bypass valve: (ESA) Polyamide
Magnetic core: (ESB) Syntherized magnetic material
Suction strainer
Collapse, dierential: 100 kPa (1 bar)
Setting: 30 kPa (0,3 bar) ± 10%
MATERIALS
DESCRIPTION
PRESSURE
BYPASS VALVE
From -25° to +110° C
Full with uids: HH-HL-HM-HR-HV-HTG
(according to ISO 6743/4)
For uids dierent than the above mentioned,
please contact our Customer Service.
Is this datasheet the latest release? Please check on our website
WORKING TEMPERATURE
COMPATIBILITY (ISO 2943)
HYDRAULIC DIAGRAM
Qmax 600 l/min
FLOW RATE
26
ESA
SUCTION FILTERS
E S A FILTER ELEMENT FAMILY
SIZE & LENGTH
11 21 2A 22 30 31 32 40 41 42 43 51 52
PORT TYPE
B = BSP thread B B B B B B B B B B B B B
N = NPT thread N N N N N N N N N N N - -
PORT SIZE
03 = 3/8" 03 - - - - - - - - - - - -
04 = 1/2" 04 04 04 - - - - - - - - - -
06 = 3/4" - 06 06 - - - - - - - - - -
08 = 1" - - - 08 - - - - - - - - -
10 = 1" 1/4 - - - - 10 10 10 - - - - - -
12 = 1" 1/2 - - - - 12 12 12 12 12 - - - -
16 = 2" - - - - - - 16 16 16 16 - - -
20 = 2" 1/2 - - - - - - - - - 20 - - -
24 = 3" - - - - - - - - - 24 24 - -
28 = 3" 1/2 - - - - - - - - - - - 28 -
32 = 4" - - - - - - - - - - - - 32
BYPASS VALVE
W = without W W W W W W W W W W W W W
A = 30 kPa (0,3 bar) D D D D D D D D D D D D D
FormulaUFI MEDIA
ME = FormulaUFI.WEB 60 µm ME ME ME ME ME ME ME ME ME ME ME ME ME
MF = FormulaUFI.WEB 90 µm MF MF MF MF MF MF MF MF MF MF MF MF MF
MG = FormulaUFI.WEB 250 µm MG MG MG MG MG MG MG MG MG MG MG MG MG
ORDERING AND OPTION CHART
27
ESB
SUCTION FILTERS
E S B FILTER ELEMENT FAMILY
SIZE & LENGTH
11 21 2A 22 30 31 32 40 41 42 43 51 52
PORT TYPE
B = BSP thread B B B B B B B B B B B B B
N = NPT thread N N N N N N N N N N N - -
PORT SIZE
03 = 3/8" 03 - - - - - - - - - - - -
04 = 1/2" 04 04 04 - - - - - - - - - -
06 = 3/4" - 06 06 - - - - - - - - - -
08 = 1" - - - 08 - - - - - - - - -
10 = 1" 1/4 - - - - 10 10 10 - - - - - -
12 = 1" 1/2 - - - - 12 12 12 12 12 - - - -
16 = 2" - - - - - - 16 16 16 16 - - -
20 = 2" 1/2 - - - - - - - - - 20 - - -
24 = 3" - - - - - - - - - 24 24 - -
28 = 3" 1/2 - - - - - - - - - - - 28 -
32 = 4" - - - - - - - - - - - - 32
BYPASS VALVE
X = not available X X X X X X X X X X X X X
FormulaUFI MEDIA
ME = FormulaUFI.WEB 60 µm ME ME ME ME ME ME ME ME ME ME ME ME ME
MF = FormulaUFI.WEB 90 µm MF MF MF MF MF MF MF MF MF MF MF MF MF
MG = FormulaUFI.WEB 250 µm MG MG MG MG MG MG MG MG MG MG MG MG MG
ORDERING AND OPTION CHART
ØD2
E1
E
ØD1
E2
ESA - 60%
28
INSTALLATION DRAWING
D1 D2 E E1 E2 Kg
ESA11
3/8" -1/2" 52 73 12 8 30 0,05
ESA21
1/2" - 3/4"
70 92 13 11
42
0,25
ESA2A
1/2" - 3/4" 70 141 13 11 42 0,25
ESA22
1" 70 137 13 11 42 0,25
ESA30
1"1/4 - 1"1/2 99 135 15 8 70 0,30
ESA31
1"1/4 - 1"1/2 99 178 15 8 70 0,40
ESA32
1"1/4 - 1"1/2 - 2" 99 218 15 8 70 0,50
ESA40
1"1/2 - 2" 130 160 15 15 101 0,50
ESA41
1"1/2 - 2" 130 201 15 15 101 0,70
ESA42
2" - 2"1/2 - 3"
130 253 15 15
101
1,00
ESA43
3"
130 330 15 15
101
1,30
ESA51
3"1/2
180 390 35 -
140
2,80
ESA52
4"
180 440 35 -
140
3,00
FILTER HOUSING
ESA
SUCTION FILTERS
ØD2
E1
E3
E
ØD1
ESB - 60%
29
INSTALLATION DRAWING
D1 D2 E E1 E3 Kg
ESB11
3/8" -1/2" 52 73 12 9 30 0,10
ESB21
1/2" - 3/4"
70 92 13 12
42
0,30
ESB2A
1/2" - 3/4" 70 141 13 12 42 0,30
ESB22
1" 70 137 13 12 42 0,30
ESB30
1"1/4 - 1"1/2 99 135 15 12 70 0,35
ESB31
1"1/4 - 1"1/2 99 178 15 12 70 0,45
ESB32
1"1/4 - 1"1/2 - 2" 99 218 15 14 70 0,60
ESB40
1"1/2 - 2" 130 160 15 14 70 0,60
ESB41
1"1/2 - 2" 130 201 15 14 70 0,80
ESB42
2" - 2"1/2 - 3"
130 253 15 14
101
1,20
ESB43
3"
130 330 15 14
101
1,50
ESB51
3"1/2
180 390 35 14
140
3,00
ESB52
4"
180 440 35 14
140
3,20
FILTER HOUSING
ESB
SUCTION FILTERS
Δp (kPa)
5
ESA 11- ESB 11
0
10 20 25 30
1
2
3
4
l/min
15
Δp (kPa)
100
ESA 51-52
ESB 51-52
0
200 400 500 600
1
2
3
4
l/min
300
p (kPa)
10
ESA 21-2A-22 ESB 21-2A-22
0
20 40 50 60
1
2
3
4
l/min
30
Δp (kPa)
100
0
200 400 500 600
1
2
3
4
l/min
300
1/21/23/83/8
3
31/21/2
111/2
1/2
2
21/21/2
1/2"
1/2" 3/4"3/4"
1"1"
2"
2"
Δp (kPa)
50
ESA 30-31-32 ESB 30-31-32
0
100 200 250 300
1
2
3
4
l/min
150
111/41/4 111/21/2
3"
3"
4"4"
ESA 40-41-42-43 ESB 40-41-42-43
SUCTION FILTERS
Recommended
Range
2"2"
2” 1/2 3” 1/2
550
500
450
400
350
300
250
200
150
100
50
0
3/8” 1/2” 3/4” 1” 2” 4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
ESA-ESB
FLOW RATE [l/min]
PORT SIZE
Δp (kPa)
5
ESA 11- ESB 11
0
10 20 25 30
1
2
3
4
l/min
15
Δp (kPa)
100
ESA 51-52
ESB 51-52
0
200 400 500 600
1
2
3
4
l/min
300
p (kPa)
10
ESA 21-2A-22 ESB 21-2A-22
0
20 40 50 60
1
2
3
4
l/min
30
Δp (kPa)
100
0
200 400 500 600
1
2
3
4
l/min
300
1/21/23/83/8
3
31/21/2
111/2
1/2
2
21/21/2
1/2"
1/2" 3/4"3/4"
1"1"
2"
2"
Δp (kPa)
50
ESA 30-31-32 ESB 30-31-32
0
100 200 250 300
1
2
3
4
l/min
150
111/41/4 111/21/2
3"
3"
4"
4"
ESA 40-41-42-43 ESB 40-41-42-43
SUCTION FILTERS
Recommended
Range
2"2"
2” 1/2 3” 1/2
550
500
450
400
350
300
250
200
150
100
50
0
3/8” 1/2” 3/4” 1” 2” 4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
ESA-ESB
FLOW RATE [l/min]
PORT SIZE
Δp (kPa)
5
ESA 11- ESB 11
0
10 20 25 30
1
2
3
4
l/min
15
Δp (kPa)
100
ESA 51-52
ESB 51-52
0
200 400 500 600
1
2
3
4
l/min
300
p (kPa)
10
ESA 21-2A-22 ESB 21-2A-22
0
20 40 50 60
1
2
3
4
l/min
30
Δp (kPa)
100
0
200 400 500 600
1
2
3
4
l/min
300
1/21/23/83/8
3
31/21/2
111/2
1/2
2
21/21/2
1/2"
1/2" 3/4"3/4"
1"1"
2"
2"
Δp (kPa)
50
ESA 30-31-32 ESB 30-31-32
0
100 200 250 300
1
2
3
4
l/min
150
111/41/4 111/21/2
3"
3"
4"4"
ESA 40-41-42-43 ESB 40-41-42-43
SUCTION FILTERS
Recommended
Range
2"2"
2” 1/2 3” 1/2
550
500
450
400
350
300
250
200
150
100
50
0
3/8” 1/2” 3/4” 1” 2” 4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
ESA-ESB
FLOW RATE [l/min]
PORT SIZE
Δp (kPa)
5
ESA 11- ESB 11
0
10 20 25 30
1
2
3
4
l/min
15
Δp (kPa)
100
ESA 51-52
ESB 51-52
0
200 400 500 600
1
2
3
4
l/min
300
p (kPa)
10
ESA 21-2A-22 ESB 21-2A-22
0
20 40 50 60
1
2
3
4
l/min
30
Δp (kPa)
100
0
200 400 500 600
1
2
3
4
l/min
300
1/21/23/83/8
3
31/21/2
1
11/21/2
2
21/21/2
1/2"
1/2" 3/4"3/4"
1"1"
2"
2"
Δp (kPa)
50
ESA 30-31-32 ESB 30-31-32
0
100 200 250 300
1
2
3
4
l/min
150
111/41/4 111/21/2
3"
3"
4"4"
ESA 40-41-42-43 ESB 40-41-42-43
SUCTION FILTERS
Recommended
Range
2"2"
2” 1/2 3” 1/2
550
500
450
400
350
300
250
200
150
100
50
0
3/8” 1/2” 3/4” 1” 2” 4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
ESA-ESB
FLOW RATE [l/min]
PORT SIZE
Δp (kPa)
5
ESA 11- ESB 11
0
10 20 25 30
1
2
3
4
l/min
15
Δp (kPa)
100
ESA 51-52
ESB 51-52
0
200 400 500 600
1
2
3
4
l/min
300
p (kPa)
10
ESA 21-2A-22 ESB 21-2A-22
0
20 40 50 60
1
2
3
4
l/min
30
Δp (kPa)
100
0
200 400 500 600
1
2
3
4
l/min
300
1/21/23/83/8
3
31/21/2
111/2
1/2
2
21/21/2
1/2"
1/2" 3/4"3/4"
1"
1"
2"
2"
Δp (kPa)
50
ESA 30-31-32 ESB 30-31-32
0
100 200 250 300
1
2
3
4
l/min
150
111/41/4 111/21/2
3"
3"
4"4"
ESA 40-41-42-43 ESB 40-41-42-43
SUCTION FILTERS
Recommended
Range
2"2"
2” 1/2 3” 1/2
550
500
450
400
350
300
250
200
150
100
50
0
3/8” 1/2” 3/4” 1” 2” 4”3”1” 1/4 1” 1/2
0,1< v < 1 m/s
ESA-ESB
FLOW RATE [l/min]
PORT SIZE
30
All the curves have been obtained with mineral oil having a kinematic viscosity
30 cSt and specic gravity 0,86 kg/dm
3
; for uids with dierent features, please
consider the factors described in the rst part of this catalogue. All the curves
are obtained from test done at the UFI FILTERS HYDRAULICS Laboratory,
according to the specication ISO 3968. In case of discrepancy, please check the
contamination level, viscosity and features of the uid in use.
PRESSURE DROP CURVES (ΔP)
N.B.
The Pressure Drop (Δp) must be lower than 3 kPa (0,03 bar).
ESA-ESB
SUCTION FILTERS
MAINTENANCE
The best time to change your lter element is just before it reaches
its maximum dirt-holding capacity. When it is time to change the lter
element, switch o the system before opening the tank.
Remove the dirty lter element and replace it with an original UFI
Hydraulics element, verifying the part number on the lter cap or in the
ordering and option chart. Close the tank.
N.B. The exhausted lter elements and the oil dirty lter parts are
classied “Dangerous waste material” and must be disposed of
according to the local laws, by authorized Companies.
We recommend the stocking of a spare UFI Hydraulics lter element for
timely replacement when required.