EG-F2A 2 WAY PRESSURE COMPENSATED PROPORTIONAL FLOW REGULATOR
DESCRIPTION
10 size, 7/8-14 thread, “Delta” series, solenoid operated, normally closed, poppet style, restrictive type 2 ways
pressure compensated proportional ow regulator.
OPERATION
EG-F2A maintains a constant ow rate out of (2) regardless of load pressure variations in the circuit downstream
of (1). When coil is not energized, there is no regulated ow out of (2). The valve begins to respond to load
variations when the ow through the valve creates a pressure differential across the control spool.
Reverse ow from (2) to (1) returns through the control spool and is not compensated.
OPERATION OF MANUAL OVERRIDE OPTION: to override, turn the manual override screw counterclockwise.
To release turn the manual override screw clockwise.
FEATURES
• Hardened parts for long-life.
• Industry common cavity.
• Excellent linearity and low hysteresis characteristics.
• Cartridges are voltage interchangeable.
• Optional coil voltages and terminations available.
• Unitized, molded coil design.
• Continuous duty rated solenoid.
800
0
20
10
15
30
600400 500
700 900 1000
I (mA)
FLOW (lt/min) vs. CURRENT (mA - PWM @ 100 Hz)
14 bar COMPENSATED
Q (lt/min)
1200 150014001300
25
40
35
50
45
5
300
800
0
20
10
15
30
600400 500
700
900 1000
I (mA)
FLOW (lt/min) vs. CURRENT (mA - PWM @ 100 Hz)
14 bar COMPENSATED
Q (lt/min)
1200 150014001300
25
40
35
45
5
300
Flow Range See curves for various versions
Max System Pressure 3500 PSI (241 bar)
Leakage 0-10 drops / min @ 245 bar
Hysteresis ±5%
Viscosity Range 36 to 3000 SSU (3 to 647 cSt)
Filtration ISO 18/16/13
Media Operating Temp. Range -30°C / +100°C
Operating Fluid Media General Purpose Hydraulic Fluid
Cartridge Torque Requirements 30 ft-lbs (41 Nm)
Coil Nut Torque Requirements 2-3 ft-lbs (3-4 Nm)
Cavity T308
Cavity Tools Kit
(form tool, reamer, tap) K-T308
Current Supply Characteristics PWM (Pulse Width Modulation)
Rated Current Range 400-1400 mA
PWM or Super-Imposed
Dither Frequency 100 Hz
Coil Resistance (12 VDC) 7.2 Ohm ±5% at 68°F (20°C)
VALVE SPECIFICATIONS
COIL SPECIFICATIONS
Port (1) must be connected
in the manifold to port (3).
HYDRAULIC SYMBOL
PERFORMANCE
Flow (lt/min) vs. Current (mA - PWM @ 100 Hz)
14 bar Compensated
Q (l/min)
l (mA)
1
2
3
2
3