c
2021 Sun Hydraulics 1 of 2
MODEL
DSEY
3-way, 2-position, vent-to-shift diverter valve, normally open
SERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-32A
(X)CONTROL
X Not Adjustable
(D)MINIMUM CONTROL PRESSURE
D 50 psi (3,5 bar)
C 30 psi (2 bar)
E 75 psi (5 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
CONFIGURATION
X Control Not Adjustable
D Minimum Control
Pressure
50 psi (3,5 bar)
N Seal Material Buna-N
(none) Material/Coating Standard
Material/Coating
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This vent-to-shift diverter valve is a 2-position, 3-way cartridge that is normally open from port 3 to port 4. When
port 1 is vented, the pressure differential between port 3 and port 1 exceeds the spring force causing the valve to
shift, thereby connecting port 3 to port 2.
TECHNICAL DATA
Cavity T-32A
Series 2
Capacity 120 L/min.
Maximum Operating Pressure 350 bar
Nominal Vent Flow 0,38 L/min.
Valve Hex Size 28,6 mm
Valve Installation Torque 61 - 68 Nm
Seal kit - Cartridge Buna: 990032007
Seal kit - Cartridge Polyurethane: 990032002
Seal kit - Cartridge Viton: 990032006
Model Weight 0.31 kg.
sunhydraulics.com/model/
DSEY
TECHNICAL FEATURES
This valve is not bistable; it is capable of modulating between the two positions shown.
Vent flow out of port 1 is pressure compensated and is listed in Technical Data.
There must be a pressure source at port 3, relative to port 1, to shift the valve.
One application of this valve is to be used in pairs to select between 2 motors or pumps.
One pilot valve may be used to vent multiple diverter valves if blocking checks are used at port 1 of each diverter. If blocking checks are not used there will be
interaction between high and low pressure legs of the circuit.
The vent-to-shift function is self cleaning and therefore insensitive to contamination.
Hardened spool and sleeve provide consistent and low spool leakage rates and excellent wear characteristics.
Incorporates the Sun floating-style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
Model Code Example: DSEYXDNCONFIGURATION OPTIONS
c