c
2019 Sun Hydraulics Corporation 1 of 2
MODEL
RVID8
Ventable, pilot-operated, balanced piston relief main stage with integral T-8A
control cavity and drain to port 4
SERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a normally closed modulating element that incorporates an integral pilot control cavity. It is ventable,
externally drained, and is a balanced piston design. The pilot control cavity will accept any T-8A pressure control
cartridge. When the pressure at the inlet (port 1) reaches the pilot control cartridge setting, the modulating element
starts to open to tank (port 2), throttling flow to regulate the pressure. The pilot cartridge's setting determines the
difference in pressure between the inlet (port 1) and the drain (port 4). The vent port (port 3) that tees in between
the main piston and pilot control cartridge, allows the modulating element to also be controlled by remote pilot or 2-
way valves.
TECHNICAL DATA
Cavity T-24A
Series 4
Capacity 480 L/min.
Max. Operating Press. 350 bar
Pilot Control Cavity T-8A
Pilot Control Valve Installation Torque 27 - 33 Nm
Pilot Control Valve Hex Size 22,2 mm
Main stage leakage at 110 SUS (24 cSt) 80 cc/min.@70 bar
Response Time - Typical 10 ms
Valve Hex Size 41,3 mm
Valve Installation Torque 474 - 508 Nm
Seal kit - Cartridge Buna: 990024007
Seal kit - Cartridge Polyurethane: 990024002
Seal kit - Cartridge Viton: 990024006
Model Weight 1.48 kg.
snhy.com/
RVID8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES
c
2019 Sun Hydraulics Corporation 2 of 2
(W)MINIMUM CONTROL PRESSURE
W 100 psi (7 bar)
D 25 psi (1,7 bar)
(N)SEAL MATERIAL
N Buna-N
V Viton
TECHNICAL FEATURES
Will accept maximum pressure at port 2; suitable for use in cross port relief circuits.
Main stage orifice is protected by a 150-micron stainless steel screen.
Not suitable for use in load holding applications due to spool leakage.
Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
NOTE: With the -8 control option, the main stage valve should first be installed to the correct torque value. The T-8A pilot control valve should then be installed into
the main stage valve to its required torque value.
The -8 control option allows the pilot control valve to be incorporated directly into the end of the relief cartridge via the T-8A cavity. These pilot control cartridges are
sold separately and include electro-proportional, solenoid, air pilot, and hydraulic pilot operation. See Pilot Control Cartridges.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.
PERFORMANCE CURVES
RELATED MODELS
RVID Ventable, pilot-operated, balanced piston relief valve with drain to port 4
Model Code Example: RVID8WNCONFIGURATION OPTIONS