MODEL
RVCD8
Ventable, pilot-operated, balanced piston relief main stage with integral T-8A
control cavity and drain to port 4
SERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
NOTE: DATA MAY VARY BY CONFIGURATION. SEE CONFIGURATION SECTION.
This valve is a normally closed modulating element that incorporates an integral pilot control cavity. It is ventable,
externally drained, and is a balanced piston design. The pilot control cavity will accept any T-8A pressure control
cartridge. When the pressure at the inlet (port 1) reaches the pilot control cartridge setting, the modulating element
starts to open to tank (port 2), throttling flow to regulate the pressure. The pilot cartridge's setting determines the
difference in pressure between the inlet (port 1) and the drain (port 4). The vent port (port 3) that tees in between
the main piston and pilot control cartridge, allows the modulating element to also be controlled by remote pilot or 2-
way valves.
TECHNICAL DATA
Cavity T-21A
Series 1
Capacity 60 L/min.
Maximum Operating Pressure 350 bar
Control Pilot Flow 0,11 - 0,16 L/min.
Pilot Control Cavity T-8A
Main stage leakage at 110 SUS (24 cSt) 30 cc/min.@70 bar
Response Time - Typical 10 ms
Valve Hex Size 22,2 mm
Valve Installation Torque 41 - 47 Nm
Seal kit - Cartridge Buna: 990021007
Seal kit - Cartridge EPDM: 990021014
Seal kit - Cartridge Polyurethane: 990021002
Seal kit - Cartridge Viton: 990021006
Model Weight 0.13 kg.
snhy.com/
RVCD8
Compound cartridge (pilot and main stage) assembly information is provided for reference only. Cartridges must be ordered separately and assembled at
point of use.
NOTES